Loading…
Loading…
9,623 results • Best match
At New Alipore : Thorough renovation and repairing works after combining two type-IV flats into one flat and other ancillary works in different blocks of New Alipore Railway Officers Colony under Assistant Engineer[Works]/II/Sealdah.
... SANITARY INSTALLATIONS 17.1S General Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with 17.2 manually controlled device (handle lever), conforming to IS : 7231, with all ...
Construction of Primari School at Adkachepda Dist. Kondagaon.
30 19 19.4 19.4.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step ...
Construction of Primari School at Pala Dist. Kondagaon.
30 19 19.4 19.4.1 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step ...
Renovation and up-gradation of toilet block (GF to fourth floor) of 156 men barrack at 25th Bn, SSB Ghitorni, New Delhi
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.40 mm nominal dia Pipes
REPAIR AND MAINT AND CLEANING OF PVC AND RCC TANK CLEANING AT JCOS ORS CIVILIANS MD ACCN OTM ACCN AND RELATED WORKS UNDER ZONE C AREA AT NDA KHADAKWASLA
... reducer elbows, unions, Tank Nipples, Floot valve and similar fittings from existing water supply lines and relieving air lock of water circulation system from outlet of overhead tank to all connected GI pipe fittings, complete all as specified and as directed by Engineer-in-Charge. Note: (a) ...
Kalidas Marg sthit Awas Sankhya-11 (Maanniya Mukhya Nyayadhish Awas) me samast darwazon/ khidkiyon ki polish karna, bathroom ki shatigrast tiles badalna, suraksha karmiyon hetu shade dalna, awas me Endura tiles par floor paint karna, awas ke vahya bh
Providing and fixing Chlorinated Polyyinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plains & brass threated fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joints of pipe and fitting with one step ...