Loading…
Loading…
3,747 results • Best match
Investigation, Survey (On G.I.S. Basis), construction of Waste Stablization Pond 600,100 KLD with 3KLD co-treatment Plant, I D of drains and structure, treated effluent line with SCADA etc.
Survey (GIS based), Soil investigation, Engineering, Design (hydraulic and structural) as required, procurement of all labour & material, T&P etc. for completion of various components under “Used Water Management Project in Gangapur Nagar Panchayat Distt. Varanasi”. It includes Interception and Diversion works of all existing drains, conveyance network and establishment of Centralized/ De-centralized Sewage Treatment Plant(s) based on open technology, inclusive of 3 KLD Co-Treatment facility for Fecal Sludge/ Septage, ensuring the final effluent parameter strictly complies with the National Green Tribunal (NGT) latest guidelines i.e. BOD10mg/l, TSS 20mg/l, Nitrogen-Total10mg/l, Total Phosphorus 1mg/l, Fecal coliform100 MPN & COD50mg/l
CONSTRUCTION OF PROPOSED SEWERAGE TREATMENT PLANT , LAYING OF SEWER LINES and CONSTRUCTION OF MAIN HOLE Drilling of Tubewells , Construction of Boosting Station , Laying of Rising Main , Internal Distribution System and Independent Feeder
SEWAGE TREATMENT PLANT :-Design, construction, erection, testing and commissioning of 2.50 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including Landscaping MCC Panel room and all other contingent Electrical, Mechanical, Electromagnetic Flow Measurement Device, Real Time Water Quality Monitoring with Data Collection System(Online analyzer), Piping and Instrumentation works with PLC and SCADA Arrangement for STP and MPS along with Synchronizing it with each other including furniture and laboratory equipments as per detail given in the bid document and including . i) 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED energy outdoor suitable size reputed make efficient lamps on each pole, including 20 no. LED outdoor lights with GI poles 7 mtr high including all accessories along the road and path complete in all respect. ii) Supply and installation of 1 No. Main Gate of (SS) 12 ft. wide main gate and 4 ft. wide wicket gate (total weight not less than 500 kg) at STP site. as per satisfaction of Engineer-in-charge. iii) Providing and installing 2 No. centrifuges (1Working plus 1 Stand bye) including centrifuge feed pump, all fittings, instrumentations, electric panel board etc. as per design complete in all respect of the NIT, including packing dry sludge in 20Kg Bag and supplying the same Market KisanSewa Kendra or as directed by Engineer-in-charge within lead as pointed at clause 4.4.5 of NIT including . iv) Providing and installation of 2 nos. pumping sets of suitable size (1 working and 1 standby) with head 15 mtrs. in chlorination tank to disposed off the treated effluent including all fittings, instrumentations, electric panel board etc. as per design complete in all respect including . v) Supply, Installation, Testing, Commissioning, operation and Comprehensive Annual Maintenance of effluent quality monitoring system at 2.50 MLD STP at Village for Online (Continuous) measuring of PH, total Suspended Solids (TSS) Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cable, local data acquisition and display the data of continuous basis for up linking the data of CPCB, HSPCB and PHED, TUV Board approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents and as contained in scope of work in the notice inviting tender:Multi-parameter measuring converter, for connecting up to 18 intelligent seniors Scope including 8 analog inputs/Outputs(4 Inputs and 4 outputs) (o/4- 20Ma), wide range power supply optical COD/BOD and TSS probe with spectral processing of the UV-VIS range for measurement plant of 2.50 MLD STP at with integrated with automatic cleaning. Robust digital pH/ORP sensor for pH/ORP electrodes, with built-in pre-amplifier and temperature sensor with Automatic Temperature Compensation (ATC) Cable length 100 Meter (minimum).Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to intelligent sensors net system cable length 100 Meter (Minimum) Data Transfer to CPCB, HSPCB and PHED Servers ). Providing GSM 3G, 4G Modem with mobilenetwork connectivity including network charges.
O M Sewerage Schemes TSS Mace Running contract 2026 27 Robotic cleaning of manholes for eliminating manual scavenging during operation and maintenance of sewerage system under Sewerage Sections Sasthamangalam and Medical College Sewerage Work
OD336447/2025-2026:Removal of dumped earth, silt, deposits received from Manhole etc by lorry for Minimum mechanical conveyance and disposing at muttathara sewage treatment plant
Construction of Administrative Building for Canara Bank at Amaravati, Andhra Pradesh including internal water supply, sanitary installations, drainage, internal electrical installations and fans, fire fighting system with wet riser, automatic fire ... system, STP , ...
Investigation, Survey (On G.I.S. Basis) and Construction of Interception and Diversion works with treatment facilities alongwith treated effluent line etc. in zone-1, 2 , 3 in Patla Nagar Panchayat, Distt- Ghaziabad U.P. India
Survey, design,construction, testing, commissioning of Sewage Treatment Plant based on Any Proven Technology for inlet sewage parameters as per mention in bid document consisting of sludge dewatering and storage unit, disinfection system and associated infrastructure including foundation, Storm water drainage system, Roads ad Pathways Landscaping. Administrative building with laboratory, treated effluent line etc complete as turn key job with all civil, electrical,instrmentation and mechanical works, labour, and T&P etc complete to achieve following design effluent parameters: 1. BOD10ppm 2. COD 50ppm 3. TSS 10ppm 4. TP 1ppm 5. TN10ppm 6. Fecal Coliform: Desirable 100 MPN per 100 ml and permissible 230MPN per 100 ml
CONSTRUCTION OF 144 EWS RESIDENTIAL INCLUDING INTERNAL INFRASTRUCTURE & DEVELOPMENT WORK WITHIN THE PLOT AT TP. 13 (BAHERAMPURA) FP.03 IN AHMEDABAD CITY
water supply to DU's, Tertiary Sewage Treatment Plant