Loading…
Loading…
3,848 results • Best match
SPECIAL REPAIRS FOR ROOF TREATMENT OF MAIN OFFICE BUILDING CDA, CHENNAI
M&L for Preparing of Existing substrates must be cleaned to remove all dirt, mildew and other contaminants. Treat areas affected by Algae, moss or fungal growth with biocide wash solution and pressure cleaning equipment with a minimum capability of 100-140 bar water pressure. All grease, oils and asphalt materials must be removed completely. All surface cracks up to 5 mm width should be filled up with Dr. Fixit Crack-X or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP.Cracks more than 5 mm and all separation gaps should be filled up with Dr. Fixit Pidicrete URP modified mortar or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP. Priming using Dr. Fixit Prime seal or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP diluted in 2:1 ratio with water (2 parts Prime seal diluted with 1 part water) @ 8-10 sq mtr per litre for a single coat application to achieve about 20 – 25 microns DFT. Allow it to dry for 6-8 hrs. Apply one coat of Dr. Fixit Raincoat Waterproof Coating or its techno commercial equivalent in BASF/FOSROC/CICO/MC-BAUCHMIE/STP without dilution by brush or roller for walls at the thickness of 120 – 130 microns all as specified and directed . Note: All above treatment will be measured as one unit of square metre and paid accordingly.
Construction of Admin Block and Quarter Guard building at 25th BN ITBP, Tezu, Arunachal Pradesh.
SEWERAGE TREATMENT PLANT -Supply, Installation, Engineering, Testing and Commissoning of sewage treatment plant All items to include providing all materials and its assembly, Labour, Consumables etc. as per standards and specifications, approved shop drawings at site. Sewage Treatment Plant (STP) using Moving Bed Bio Reactor (MBBR) of capacity 10 (STP)cum per day in civil construction and releted works including Design, Engineering, and preparation of providing all equipment / Piping etc at site, erection testing and commisioning of equipments/ electricals/ piping including carriage etc. for Sewage treatment plant and system requirement to meet the parameters for reusing water for gardening , washing, flushing etc. The plant comprises of the following except civil construction i.e. Bar Screen Chamber, Sludge holding tank, Equilization tank, sludge drying beds, treated water tank, grease trap, MBBR calorifier, raw sewage pumps, diffusers, air blowers, filter feed pumps, chlorine doser, MGF, ACF, piping, automated control panel, level switches etc. complete in all respect, which will be provided by the vendor. Treated sewage parameters should be as per CPCB norms . Vendor need to submit test certificate from approved PCB lab. -Cap. 10cubm.
Replacement of fire hydrant system at Lilabari Airport
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
QUANTUM OF WORK schedule of maintenance and attending breckdown 33/11 KV Substation in the area of Electricity Distribution Division-Purwa, Unnao.
Supply and fixing holding clamps for PCC/STP with nuts & Bolts
Construction of 2 Nos. S and S tank, Construction of WTP capacity 0.50 MLD, Construction of Clear water tank, Providing and installing pumping machinery for raw water and clear water
H.S.R. Items DNIT Name :DNIT for Providing raw water arrangement, construction of raw water pumping station at Nigana feeder, laying of raw water rising main, upgradation of existing water works structures and laying of distribution system in village Dang Khurd Tehsil Tosham District Bhiwani” Construction of 1 No. RCC S/S Tank, Construction of CWT, Pump Chamber, Suction well for Raw water and Clear water, Water Treatment Plant 0.50 MLD, Pumping Machinery, Pipe line for Head works, C.C. Road and Path, Re-construction of Boundary wall, Construction of Sump well Pump Chamber, Boundary wall Pumping Machinery, Laying of rising main, Construction of RCC open inlet channel, Distribution system and operation and maintenance during defect liability period of 12 months after successful completion of 3 Months trial run and thereafter for 5 years in village Dang Khurd and all other works contingent thereto”
Construction /Redevelopment of Infrastructure at Kibithoo BOP of 25th Battalion ITBP, Tezu (Arunachal Pradesh), including ORs Accommodation, Cook House, Recreation Hall, Coy Office with OPs Room and WT Station, MI Room, Clothing/Ration/Miscellaneous
SEWERAGE TREATMENT PLANT -Supply, Installation, Engineering, Testing and Commissoning of sewage treatment plant All items to include providing all materials and its assembly, Labour, Consumables etc. as per standards and specifications, approved shop drawings at site. Sewage Treatment Plant (STP) using Moving Bed Bio Reactor (MBBR) of capacity 10 (STP)cum per day in civil construction and releted works including Design, Engineering, and preparation of providing all equipment / Piping etc at site, erection testing and commisioning of equipments/ electricals/ piping including carriage etc. for Sewage treatment plant and system requirement to meet the parameters for reusing water for gardening , washing, flushing etc. The plant comprises of the following except civil construction i.e. Bar Screen Chamber, Sludge holding tank, Equilization tank, sludge drying beds, treated water tank, grease trap, MBBR calorifier, raw sewage pumps, diffusers, air blowers, filter feed pumps, chlorine doser, MGF, ACF, piping, automated control panel, level switches etc. complete in all respect, which will be provided by the vendor. Treated sewage parameters should be as per CPCB norms . Vendor need to submit test certificate from approved PCB lab. -Cap. 10cubm.