Loading…
Loading…
3,901 results • Best match
Replacement of Transformers 315 KVA each, 2 Nos. with allied work at Dallupura SPS
Removal of ash deposition over the St-II Silo Road from Hydrogen Plantto Cooling Tower at NTPC Kahalgaon
Hiring of Different category of Vehicles on as and when required basis during VVIP Visits and Other Requirements for NTPC Kahalgaon for 3 Years
CERTAIN REPAIR TO OFFICER MESS AND SINGLE LIVING OFFICER ACCN AREA UNDER AGE BR-II AT NAMS
Material and labour for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WC's etc shall be as under :- (a) Application of Two component Acrylic modified cementitious coating (i) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coatings and achieve a gripping profile that is clean, dry and free from laitance and any other form of surface contamination. The installation instructions in manufacturer’s published literature should be strictly complied with, including but not limited to the following :- (ii) Chipping out any visible cracks in “V-Groove” pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/ Dr Fixit 302 SBR latex / Perma latex SBR / FOSROC Nitabond SBR latex / Asian Paints latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vacuum pressure if required. (iii) Dampen all surfaces immediately ahead of application of Acrylic modified Cementitious coating of Sika Top Seal – 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO. (iv) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic modified Cementitious coating of Sika Top Seal – 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer’s instructions. (v) Apply Glass Fabric Sheet of Sika Fab 1 / FOSROC/ Dr Fixit/ STP whilst the first coat is wet. (vi) Once touch dry, apply second coat of Acrylic modified Cementitious coating of Sika Top Seal – 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer’s instructions on the entire area. (vii) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direction right angle to the previous coat.
Construction of infrastructure at BOP Charchum of 11th Bn SSB Didihat under Frontier Hqrs Ranikhet
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
Restoration of the defective units in existing installed gaseous chlorination system at WTP under SWB W/S Scheme, Southen Sector, Haringhata, PHE Dte., Dist.- Nadia.
Supply, delivery of following spares (as per sample / relatable) for existing installed Gas Feed S10K™ Chlorinator System (evoqua) at Water Treatment Plant (WTP).