Loading…
Loading…
3,658 results • Best match
Construction of Kisan Vishram Sthal in Village Salotiaya, Dablobhoj Package Bhawanimandi-01/2026-27 Under KUMS Bhawanimandi Distt Jhalawar
Grading roof for water proofing treatment with water proffing compound, Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Construction of Kisan Vishram Sthal in Village Asnawar Under KUMS Jhalrapatan Distt Jhalawar
Grading roof for water proofing treatment with water proffing compound, Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Construction of Kisan Vishram Sthal in Village Raipur Under KUMS Bhawanimandi Distt Jhalawar
Grading roof for water proofing treatment with water proffing compound, Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Construction of Kisan Vishram Sthal in Village Raythal, Jaloda Tejaji Package Baran-03/2026-27 Under KUMS Baran Distt Baran
Grading roof for water proofing treatment with water proffing compound, Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Repair/replacement of GI/CI water supply distribution pipe lines and cleaning of BP tanks/sumps and other connected works from BP tank No 04 to DD line and SEPTA at Yol Mil Stn
Supply only best quality bleaching powder grade 'A' ISI marked for water treatment purpose, complete all as specified and directed by Engr-In-Charge. Make:- DCM Shree Ram / Declibac Technologies / Shre Rayaseema or as approved by MES.
REPAIR/ REPLACEMENT OF ROOF, PLASTER, JOINERY, SUNKEN TREATMENT, PLUMBING AND ALLIED WORKS AT RAINA PARK, GURBACHAN SINGH ENCLAVE, DOGRA FARM, CEMETARY LINE AND ROORKEE ROAD ACCN AND OTHER ADJACENT AREA UNDER AGE B/R-II OF GE (NORTH) MEERUT CANTT
M&L for Water proofing treatment to sunken floors of kitchen, toilets, bath and WC's etc shall be as under :- (i) Application of two component acrylic modified cementitious coating. (ii) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treaments and old coatings. Concrete subtrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coatings and achieve a gripping profile that is clean , dry and free from laitance and any other form of surface contamination. (iii) Chipping out any visible cracks in "V-Groove" pattern as applicable. Special attention on this part. Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 Putty/Dr. Fixit 302 SBR latex/Perma latex SBR/ FOSROC Nitobond SBR Latex/Asian Paint latex as required. Final cleaning of surface with power grinder, wire brush, hair brush & vaccum pressure if required. (iv) Dampen all surfaces immediatley ahead of application of Acrylic modified cementitious coating of Sika Top Seal-107/Brush Bond Fosroc/Dr. Fixit/STP/CICO. (v) Whilst the surface is still damp from saturation(S.S.D), apply one coat of Acrylic modified cementitious coating of SIKA Top Seal -107/Brush Bond Fosroc/Dr. Fixit/STP/CICO of viscosity as per manufacturer's instructions. (vi) Apply Glass Fabric sheet of Sika Fab 1/FOSROC/Dr Fixit/STP whilst the first coat is wet. (vii) Once touch dry, applied second coat of Acrylic modified cementitious coating of Sika Top Seal-107/Brush bond Fosroc/Dr. Fixit/STP/CICO of viscosity as per manufacturer's instructions on the entire area. (viii) Second coat shall be applied after 6-8 hrs of application of previous coat and in the direction right angle to the previous coat.