Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
1,071 results • Latest
Multimedia Projector (MMP) (Q2)
Plotter Printers (V2) (Q2)
BATTERY PACK NI CARD 24V 4AH FOR LPU 322
Repair and Overhauling Service - CAR WASHER HOSE; ELGI; Yes; Buyer Premises
PT Shoes Having Textile Upper and Shoe Canvas with Moulded Rubber Sole (Q2) (3 (3 ))
Entry and Mid Level Desktop Computer
Goods Transport Service – Per MT per KM Based Service - Military Value; Truck 9 MT Load Carrier; Truck 9 MT Load Carrier, Goods Transport Service – Per MT per KM Based Service - Military Value; Day Halt Truck 9 MT Load Carrier; Day Halt Truck 9 MT Load Carrier, Goods Transport Service – Per MT per KM Based Service - Military Value; Night Halt Truck 9 MT Load Carrier; Night Halt Truck 9 MT Load Carrier, Goods Transport Service – Per MT per KM Based Service - Military Value; Truck 15 MT Load Carrier; Truck 15 MT Load Carrier, Goods Transport Service – Per MT per KM Based Service - Military Value; Day Halt Truck 15 MT Load Carrier; Day Halt Truck 15 MT Load Carrier, Goods Transport Service – Per MT per KM Based Service - Military Value; Night Halt Truck 15 MT Load Carrier; Night Halt Truck 15 MT Load Carrier, Goods Transport Service – Per MT per KM Based Service - Military Value; Trailer 20 MT Flat Bed; Trailer 20 MT Flat Bed, Goods Transport Service – Per MT per KM Based Service - Military Value; Day Halt Trailer 20 MT Flat Bed; Day Halt Trailer 20 MT Flat Bed, Goods Transport Service – Per MT per KM Based Service - Military Value; Night Halt Trailer 20 MT Flat Bed; Night Halt Trailer 20 MT Flat Bed, Goods Transport Service – Per MT per KM Based Service - Military Value; Trailer 25 MT Flat Bed; Trailer 25 MT Flat Bed, Goods Transport Service – Per MT per KM Based Service - Military Value; Day Halt Trailer 25 MT Flat Bed; Day Halt Trailer 25 MT Flat Bed, Goods Transport Service – Per MT per KM Based Service - Military Value; Night Halt Trailer 25 MT Flat Bed; Night Halt Trailer 25 MT Flat Bed
Enamel, Synthetic, Exterior (A) Undercoating (B) Finishing (V4) Confirming to IS 2932 (Q3), Putty for use on Window Frames as per IS 419 (Q3), Ready Mixed Paint for Road Marking as per IS 164 (Q3) (3 (3 ))
High Mast Lighting Tower for large area with LED Flood Lighting System (Q3) (3 (3 ))
Material and labour point wiring for light point or fan point one light fan exhaust fan point controlled by one one way switch using 1.5 sqmm, Supply and fixed switch piano flush type single pole 5 or 6 Amps one way complete, Supply and fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete, Material and labour for sub main wiring with two run of FRLSH PVC insulated unsheathed single core multi stranded copper conductor of size 6 sqmm and one run of 4 sqmm copper, Supply and fix epoxy powder coated sheet metal enclosure for DBs double door Single pole and neutral 8 ways with mounting fitted with 200 Amps rated bus bar DIN channel, Supply and fixed MCB SPN 32 Amps C curve 10KA 240 Volts and to be housed in DBs complete including necessary connection all as specified and directed, Supply and fixed MCB SP 6 to 32 Amps C curve 10KA 240 Volts and to be housed in DBs complete including necessary connection all as specified and directed, Supply and fix BLDC Exhaust Fan 1600 RPM made of sturdy Engineering plastic complete with louvers shutter voltage 230V 50 Hz Copper winding of sweep 200mm complete all as specified and directed, M and L cutting holes round type into or through brick walls built in cement mortar of cement lime mortar and and stone walls built lime mortat or wall of lime concrete
Supply Install and testing Split AC of Capacity 1 point 5 Ton Star rating 5 Star, M and L sub main wiring with two single core 6 sqmm FRLSH PVC Cable, M and L sub main wiring with two single core 4 sqmm FRLSH PVC Cable, Supply and fix Copper pipe for fixing AC indoor and outdoor, Supply and fix PVC Drain pipe of suitable size for drain of water form AC indoor, S and F Mcb Spn 32 Amps 240 volts C Curve, S and F Modular Type AC Socket with MCB all as specified, S and F sheet metal enclosure SPN DB 8 Way, S and F sheet metal enclosure SPN DB 4 Way, S and F MCB SP 6 to 32 Amps 240 Volts 50 Hz
M and L Modular point wiring for light point, S and F Modular Switch 6 Amp 1 way 1 module size, S and F LED Luminaire 600mm x 600mm 36 watt, Supply and Install Spilit AC 1.5 Ton 5 Star, M and L sub main wiring with two single core 4 sqmm FRLSH PVC Cable, Supply and fix Copper pipe for fixing AC indoor and outdoor, Supply and fix PVC Drain pipe of suitable size for drain of water form AC indoor, S and F Sheet metal enclosure with socket plug top with sp mcb 20A
Repair and Overhauling Service - cars; Mahindra & Mahindra; Yes; Buyer Premises
WATER SEPERATOR, ELEMENT LUB OIL FILTER, ELEMENT OIL BY PASS FITER
CYLINDER ASSY PNEUMATIC, SIREN ELECTRIC MOTOR OPERATED 24V, LEVEL INDICATOR ACRYLIC TUBING
Repair and Overhauling Service - Diesel Generators- Dg Sets (DFM); Firefly Fire Pumps Pvt; Yes; Buyer Premises, Repair and Overhauling Service - Diesel Generators- Dg Sets (DFM); TATA (Pyrosafety); Yes; Buyer Premises
Industrial Safety Helmet (V3) ISImarkedto IS2925 (Q2)
Garden Sword (V3) As Per Is 12409 (Q4)
Repair and Overhauling Service - Buses for State Road Transport; TATA MOTORS; Yes; Buyer Premises
Repair and Overhauling Service - Diesel Generators- Dg Sets (DFM); escort; Yes; Buyer Premises
Repair and Overhauling Service - built up trucks; Ashok leyland; Yes; Buyer Premises
Wind Shield Washer Fluid, Premium Diesel Ow-20 TGMO, Element AIr Cleaner, Element Air Refiner, Gasket, Oil Filter
Fire Beaters (Fire suppression hand tools) (Q3), GALVANIZED MILD STEEL FIRE BUCKET (V2) Conforming to IS 2546 (Q3) (3 (3 ))
Electrodes Welding Steel Mild General, Cutting wheel 14", Fevi Quick
Front Suspension Bush Kit, Assy Link Front LH, Assy Link Front RH, OBJ Assy, Rear Front Ball Joint, Assy Ball Joint Upper Wishbone, Assy Condenser Fan, A. C Compressor
Filer Cartridge, RO Membrane, Solenoid Vessel, Pressure Vessel, O Rings, Flow Meter, PH Controller, Labor Charges
CAMERA CONTROL UNIT
High Mast Lighting Tower for large area with LED Flood Lighting System (Q3) (3 (3 ))
Flexible Wiper Blade Assly. as per CLW Drg. No: - 1209-07.303-022. To be procured from CLW approved source.
BPL Cable Assy, Coil Heating Element, BP Machine, Ball 6X Piece, Nebulizer, 12" Grinder Wheel for Dental
Controller Card (PCB), Trident Part No. : AD 1224. Make - Trident.
Supply Install and testing split AC 1.5 Ton inverter 5 Star, M and L Sub-main wiring 2x6 sq mm to Connection Point, M and L Sub-main wiring 2x4 sq mm to Connection Point, Supply and fixing MCB SPN 32A, Supply and fixing Socket enclosure with 20A MCB, Supply and fixing Single phase voltage stabilizer 4kVA, Supply and fixing SPN DB 8 way, Supply and fixing SPN DB 4 way, Supply and fixing MCB SP 6-32A B curve
Wall Mounted Storage Cabinet
Supply laying and testing cable XLPE insulated screened PVC bedded galvanized size 120 sq mm 3 core etc., Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft loose soil all as specified and as directed., Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft loose soil all as specified and as directed., Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr in charge., Supply and lay of PCC cable cover class HV type 1 flat size 300mmx180mmx40mm complete all as specified and directed., Supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm deep etc., MandL for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 90mm dia laid in trenches for cable protection complete all as spcified and directed., MandL for fixing GI tubing 80mm dia light grade use for the protection of cable all as specified and directed by Engr in Charge., MandL for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed., SandF PCC cable route marker of size 900x300x70mm embossed with HT UG cable etc., Wrecking Crow Bar or Claw Bar as per IS 706 (Q3)
Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip size 185 sq mm 3.5 core, Excavation in trenches not exceeding 1.5 m widthandnot exc 1.5m in depth getting out in soft loose soil etc., Excavation in trenches not exceeding 1.5 m widthandexc 1.5m in depth getting out in soft loose soil etc., Returning filling in including spreading levelling wateringandwell ramming in layers etc., Removal of surplus soil to a distance not exceeding 50 manddepositing where directed by Engr in charge., Supplyandlay of PCC cable cover class HV type 1 flat size 300mmx180mmx40mm etc., Supplyandlay for dry clean dirtless river sand filling for cable protection with a layer of 8cm deep etc., MandL for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 90mm etc., MandL for fixing GI tubing 80mm dia light grade use for the protection of cable etc., MandL for manual boring under road crossingandlaying pipe across the road etc., SandF PCC cable route marker of size 900x300x70mm embossed with HT UG cable etc., Materialandlabour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts and screws etc., M and L for switch air break gang operated triple pole out door type unit on HT 11 KV 50 cycle etc., M and L for 11 kV 200 Amps outdoor type Horn Gap Fuse set conforming to IS 9385 etc., M and L for cross arms bracing supports clampsandback plates fabricated from structural steel etc., M and L for pin type porcelain polymer vitreous brown insulator of size 150mm height 150mm etc., M and L for disc type porcelain polymer insulator vitreous 145 mm heightand255 mm diameter etc., M and L for lightning arrester surge protector 11 KV grade heavy duty single pole etc., S and F Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white etc., MandL for Cement concrete in foundations fillingandmass concrete etc., MandL for PCC 1 3 6 type C2 using 40mm grade aggregate as in foundation etc., MandL for PCC 1 2 4 type B1 using 20mm grade aggregate as in coping etc., M and L for Earthing complete with galvanised steel earth plate electrode etc., M and L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried etc., MandL Cable jointing kit for 11 KV Earthed grade cable for outdoor termination Heat shrink type joint etc., M and L Cable jointing kit for 11 KV Earthed grade cable for straight through heat shrink type joint complete with jointing etc., Wrecking Crow Bar or Claw Bar as per IS 706 (Q3)
M and L for cable in trenches or passing through pipe XLPE insulated heavy duty area 25 sqmm 3.5 core etc., All as per Item Ser No 01 above but of size 70 Sqmm 3.5 Core., All as per Item Ser No 01 above but of size 95 Sqmm 3.5 Core., All as per Item Ser No 01 above but of size 240 Sqmm 3.5 Core., Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr etc., Returning Filling in including Spreading Levelling Watering and Well Ramming etc., Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level etc., M and L Sand Cushioning dry in Trenches for protection of UG Cables below etc., M and L for fly ash bricks locally available laid dry width wise across etc., S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable etc., S and F Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable etc., S and F HDPE DWC Double Walled Corrugated of Diameter 40 mm including disconnection etc., S and F HDPE DWC Double Walled Corrugated of Diameter 90 mm including disconnection etc., M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia etc., M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm etc., Supply and Fixing sheet moulding compound junction box IP 66 weather proof etc., Supply and Fixing Submain wiring with five runs of 6 sqmm Three phase etc., Supply commissioning and testing Outdoor type LT Distribution Panel Double door type etc., Supply commissioning and testing Outdoor type LT Distribution Panel Double door etc., Pick Axe as per IS 273 (Q4)
Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire etc., Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth etc., Excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth etc., Returning filling in including spreading levelling watering and well ramming in layers etc., Removal of surplus soil to a distance not exceeding 50 m and depositing etc., Supply and lay of PCC cable cover class HV type 1 flat size 300mmx180mmx40mm etc., Supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm etc., M and L for Double Wall Corrugated DWC High density polyethylene pipes HDPE etc., M and L for fixing GI tubing 80mm dia light grade use for the protection of cable etc., M and L for manual boring under road crossing and laying pipe across the road etc., S and F PCC cable route marker of size 900x300x70mm embossed with HT UG cable etc., Material and labour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts and screws etc., M and L for switch air break gang operated triple pole out door type unit etc., M and L for 11 kV 200 Amps outdoor type Horn Gap Fuse set conforming to IS 9385 etc., M and L for cross arms bracing supports clamps and back plates fabricated etc., M and L for pin type porcelain vitreous brown insulator of size 150mm etc., M and L for lightning arrester surge protector 11 KV grade heavy duty single pole etc., S and F Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled etc., M and L for Cement concrete in foundations filling and mass concrete type D2 1 etc., M and L for PCC 1 3 6 type C2 using 40mm grade aggregate as in foundation etc., M and L for PCC 1.2.4 type B1 using 20mm grade aggregate etc., M and L for Earthing complete with galvanised steel earth plate electrode 60x60cm etc., M and L for Earth continuity conductor or main earthing lead fixed to wall on batten etc., Dismantling of ACSR or AAC conductors, Dismantling concrete poles struts any size, Dismantling cross arms of M.S. channel or angle sections etc., Dismantling insulators any type any size, Pick Axe as per IS 273 (Q4)
HP 110A Cartridge, HP 88A Cartridge, Canon 328 Cartridge, Canon Cartridge PFI-8120C, Canon Cartridge PFI-8120Y, Canon Cartridge PFI-8121M, Canon Cartridge PFI-8120BK, Canon Cartridge PFI-8120MBK, HP Laser Jet Black Toner W1002YC