Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
8,617 live and archived tenders were published on this date.
Adding a sidebar filter continues in Live Tenders while preserving this publication date.
8,617 results • Latest
IHQ of MoD (Army)-(OSCC)
Hose Labelling Machine
HP State Forest Development Corporation
FELLING, CONVERSION, MANUAL CARRIAGE, LOADING AND TT UP TO HSD
HP State Forest Development Corporation
FELLING, CONVERSION, MANUAL CARRIAGE, LOADING AND TT UP TO HSD
Local Self Government Department
Road Work
CE RW I
CE RW I
Department of Local Government
Department of Local Government
NTPC Limited
Department of Local Government
Department of Local Government
Rural Water Supply and Sanitation
Rural Water Supply and Sanitation
RDD-CEO-HINGOLI
Chandigarh Administration
Chandigarh Administration
Municipal Corporation
IndianOil
Procurement of N-Methyl Aniline for IOCL Depot/ Terminal at Ratlam, Korba, Indore, Itarsi, Jabapur, Gwalior and Sagar
Heavy Water Board
Providing and fixing new PPG lining after removal of acid proof brick lining in old N pit and damaged PPG lining in new N pit along with supporting civil works
Assam Rifles - MHA
National Council of Science Museums
Indian Institute of Technology Kanpur
National Aluminium Company Limited,NALCO
Indian Institute of Technology Kanpur
All India Institute of Medical Sciences
RDD-CEO-YAVATMAL
IndianOil
Haryana Government
E-IN-C BRANCH - MILITARY ENGINEER SERVICES
E-IN-C BRANCH - MILITARY ENGINEER SERVICES
Urban Administration and Development Department (UADD)
CONSTRUCTION OF SAMUDAYIK BHAWAN BY DEMOLISING OLD BHAWAN IN WARD NO -15
Urban Administration and Development Department (UADD)
CONSTRUCTION OF BOUNDRY WALL NEAR KHOOBCHAND BAGHEL BHAWAN IN WARD NO -15
Urban Administration and Development Department (UADD)
CONSTRUCTION OF SHED IN KHORPA SCHOOL AT NO -13
Urban Administration and Development Department (UADD)
CONSTRUCTION OF PUBLIC BUILDNG IN SUBHAS CHOWK AT WARD NO -10
Urban Administration and Development Department (UADD)
CONSTRUCTION OF SAMUDAYIK BHAWAN IN KHORPA AT WARD NO-13
Public Health Engineering Department (PHED)
(4th call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - BELPUTI, Block –BAKAWAND, District – BASTAR.
Public Health Engineering Department (PHED)
(4th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 50 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - DUGANPAL, Block –TOKAPAL, District – Bastar.
Public Health Engineering Department (PHED)
(2nd Call) Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Madpal, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(4th call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm di & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia UPVC class 6/10 kg/sqcm with suitable joints 100 mm dia, GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under SVS of Piped Water Supply Scheme under Jal Jeevan Mission For Village -NARAWAND-II, Block -BAKAWAND District – Bastar
Public Health Engineering Department (PHED)
(2nd Call) Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Upanpal, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(4th Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - KAMANAR, Block –DARBHA, District BASTAR
Public Health Engineering Department (PHED)
(4rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Naglsar, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(2nd Call) Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Amaguda, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(4th call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of …. mm dia & …. mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, …. mm dia & …. mm dia class 6/10 kg/sqcm with suitable joints 50 mm dia & 65 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - BADEARAPUR, Block –TOKAPAL, District – Bastar.
Public Health Engineering Department (PHED)
(4th call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 90 mm dia, 110 mm dia, 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Kakarwada, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(4rd call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 45 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia, 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia & 100 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Kawalikala, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(2nd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 40 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia & 140 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/ Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - Manganpur, Block –Jagdalpur, District – Bastar.
Public Health Engineering Department (PHED)
(4rd Call) Construction, Testing and Commissioning of R.C.C. Elevated Service Reservoir of 45 KL capacities & staging 12 mt. including providing and fixing of CI Double flange pipe, double flange specials & DI double flange soft seated sluice valve including construction of suitable R.C.C. Valve Chamber & Providing, laying, jointing, interconnection, testing and commissioning of 63 mm di & 75 mm dia HDPE PE-100 , PN-6 Pipe , 90 mm dia & 110 mm dia class 6/10 kg/sqcm with suitable joints 80 mm dia GI Pipe, valve specials and all fittings including all allied civil works, Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity three phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,SS/Nylonwireropeandconnection cable including verification of tubewell yield& Electric connection from CSEB, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(F.H.T.C) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under Retrofitting of Piped Water Supply Scheme under Jal Jeevan Mission For Village - CHHOTE KAWALI, Block -JAGDALPURDistrict – Bastar.
Across all 8,617 tenders published on this date. Statuses reflect the latest available updates; check each tender for its current deadline.
A tender can cover more than one state. Group counts may overlap.