Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | ₹29.5 L | L1 | Accepted-AOC Lowest and reasonable |
| 2 | L2₹32.5 L+₹3.0 L (10.2%)Rejected-Finance | ₹32.5 L+₹3.0 L (10.2%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹32.7 L+₹3.2 L (10.8%)Rejected-Finance | ₹32.7 L+₹3.2 L (10.8%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹32.7 L+₹3.2 L (10.9%)Rejected-Finance PLOT NO 44 SIDDARTH PARK BEHIND ICE FACTORY KODKI ROAD BHUJ PIN 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | ₹32.7 L+₹3.2 L (10.9%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹33.0 L+₹3.5 L (11.9%)Rejected-Finance | ₹33.0 L+₹3.5 L (11.9%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
31 Jul 2021, 6:00 pmClosed
GE Army Bhuj
GE Army Bhuj, Madhapar Road, Bhuj-Kutch, Gujarat- 370 001
SPL REPAIR TO TOILET BLOCKS OF BLDG NO P-03, BLDG NO. P-135, BLDG NO T-282 AND BLDG NO P-33 OF GE (A) BHUJ AT MIL STN BHUJ
2021_MES_457378_1
8841/E8
Open Tender
Civil Works
Item Rate
180 days
Bhuj Mil Stn
As Per Tender
7 documents required · 7 mandatory
₹500
GE Army Bhuj
₹78,000
Yes
12 Aug 2021
5 Jul 2021
2 Aug 2021
5 Jul 2021
31 Jul 2021
14 Jul 2021
Amount
Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) and S & F Coloured Glazed Ceramic tiles (Digital Designer tiles) of size 450 mm x 300 mm and 6-7 mm thick on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) and S & F non skid ceramic coloured tiles square / rectangular area of each tile exc 0.06 sqm but not exc 0.11 sqm and 6 - 7 mm thick as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
Roughning sufaces of old concrete floor by picking , sweeping cleaning and washing down with water to remove dust etc. Complete all as specified and directed
Demolition of precast concrete block walling and similar items ie. ashlar facing dressed stone work, precast concrete articles etc.,of any discription and in any position, built in cement mortar, including all quoins, arches and pillars etc. and disposing off the rubbish off the premises of cantonment complete all as specified and directed.
M & L for precast cement concrete block masonry with solid blocks of PCC (1:5:8) (using 20mm and 12.5 mm graded stone aggregate in the proportion as directed exc 10cm in width and set and jointed in C M 1:6 complete all as specified and directed.
Taking down cement plaster of any description and in any position of brick/concrete surfaces on walls / celing etc. including racking out joints, hacking for key, scrubbing down with water etc & prepared to receive new plaster and disposing off the rubbish off the premises of cantonment complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces , applied in two layers ie. Ist layer of 10 mm thick rendering in CM 1:6 and 2nd ( top ) layer of 5 mm thick rendering in CM 1:4( top layer mixed with water proofing compound as per manufacturer's instructions) finished even and smooth without using extra cement complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid seperately under appropriate item of Sch 'A' as "supply only")
Supply only water proofing compound (ISI Mark) complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:4) on fair faces of brick work or conrete surfaces/stone masonary and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered sufaces of walls & applying 2 coat of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of walls & applying three coats of white wash on wall surfaces complete all as specified and directed.
Dismantling water tanks of any description and in any position , of capacity exceeding 250 litres but not exceeding 500 litres and S & F Rotational moulded poly-ethylene multilayer water storage tanks (cylinderical vertical with closed top) 500 litres capacity, white in colour hoisted and fixed in position with and including all fittings and fixtures complete all as specified and directed.
S&F in repair Ball brass valves , high pressure , with polythene float and fly nut complete & high-density plastic ball , suitable for 20 mm bore pipe, screwed for iron pipe and fixed complete all as specified and directed.
Demolition of Cement Concrete (Reinforced) in roof slab,of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for Precast RCC (1:2:4) type B1 (using 20mm graded stone aggregrate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed.
M&L 100mm thick PCC 1:2:4 type B2 using 40mm graded stone aggregate as in sub base finished fair complete all as specified and directed.
Demolition of cement concrete of any description and in any position (unreinforced) in ground floors/ paving not exceeding 15 cm thick (below or above GL) complete all as specified and directed.
M&L for PCC (1:4:8) type D-2, (using 40 mm graded stone aggregate),75 mm thick, as in sub base for floor, finished even and rough complete all as specified and directed.
M&L for PCC (1:3:6) type C2, (using 40mm graded stone aggregate) as in plinth protection, 75 mm thick, finishing the surface even and smooth w/o using extra cement including forming & filling expension joints 65 mm deep x 10 mm wide filled with sealing compound grade A complete all as specified and directed.
Taking down chowkats or frames n.exc 1.5 sqm with shutters without taking off shutters from the frame and removing to store complete all as specified and directed
Taking down chowkats or frames exc 1.5 sqm & n exc 4 sqm with shutters without taking off shutters from the frame and removing to store complete all as specified and directed
Taking down existing shutters of any description and in any position exceeding 1.00 sqm but not exceeding 2 sqm each leaf complete all as specified and directed
S&F for Powder coated aluminium anodised ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified.
S&F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; panelling of prelam colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading & jointed together with solvent cement, supply & fixing in the frame at site as per SSR specifications & diagram/product drawing shown on sl page NO 146 of SSR Part II with the size of door shutter as required complete all as specified and directed
S&F solid PVC door frame of size 50mmX47mm made out of 5mm prelam colour PVC sheet reinforced with MS square tube all as per specifications and as per drawing shown on sl page No 150 of SSR part II (for item-884)
S&F 30 mm thick factory made Flush shutters , solid core construction , with block board core and plywood face panels commenrcialface on both sides with lipping/frame to match with complete all as specified and directed.
M & L for 30 mm thick glazed and skeleton shutters of 2nd class Hard Wood(Not less than Hollock wood) local made shutter, open rebated and prepare to reveive glass, guage etc (without sash bars ) edges of framing plain chamfered or rounded, fitted with moulded beads both sides for securing glass etc, size of members of shutters as specified in SSR part I section 8 clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
S&F 100 mm long butt hinges stainless steel medium weight and fixed to wooden or PVC frame fixed in repairs by stainless steel screw as directed
S&F aluminum handles cast type, anodized of 150 mm size complete all as specified and directed.
S&F 150 mm long aluminium anodised , barrel tower bolt of extruded section and fixed all as specified and directed.
S&F butt hinges 100mm long medium weight, cold rolled mild steel complete all as specified and directed
S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F in repair vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white with integral foot rests and connection to trap and to flushing pipe, anti syphonage pipe etc(including flushing cistern and flush pipe) complete with provision of lime concrete bedding including taking down existing unserviceable WC of any discription and in any position & fixing new WC in repair and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S&F in repair Vitreous China, wash down water closet pan "Pedestal pattern" white including P TRAP OR S TRAP and connection to drain and to flush pipe(flushing cistern include) and anti syphonic pipe including all joints and making good the disturbed surfaces complete all as specified.
S & F in repair vitreous china urinals spreader bowl type flat back size 465 x 355 x 265 mm white including providing and fixing plugs bedding urinal against wall CM 1:2 securing urinal with 60mm long brass screws pointing arround urinal back in cement, fixing grating and urion for discharge pipe complete all as specified and directed
S&F PVC connections 15 mm dia and 450 mm long with brass nuts complete all as specified and directed
S&F in repair PVC valve-less, syphonic action type, flushing cistern, low level, 10 litre capacity (ISI marked) white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F Roof trusses (framed) trusses purlins and fastening (etc.tubular section,round pipe) or flat section including distance pieces, MS plates/ gusset plates, cleats, hold fast etc. conforming to Gde of steel Fe 410-0 or Fe 310-0 complete all as specified and directed.
Preparation of new painted surface of steel and iron surface of any description and in any position over 10 cm width or girth and M&L for applying two coat of synthetic enamel paint over one coat of redoxide primer complete all as specified and directed
Dismantling plain or corrugated A/C or steel sheeting, any guage of any description and in any position as in roof coverings and S &F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550MPa as in roof covering / cladding to wall, fixed with L or J hooks all as specified and directed.
Dismantling plain or corrugated A/C or steel sheeting, any guage of any description and in any position as in roof coverings and S &F for pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550MPa as in ridge etc fixed with L or J hooks all as specified and directed.
S & F in repair vitreous china wash basin,white flat back , size 550mmx450mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated, fancy type, pillar tap, 15mm bore, scrwed down high pressure with or without lettereed hot or cold with long shanks, screwed for iron pipe complete all as specified and directed.
S&F in repairs Under Counter Basin with Fixing Accessories, with waste coupling (Make Jaquar Cat No CNS-WHT-705 Wash Basin Size (mm) Size: 595x420x200mm and & ALD-705 (waste Coupling 32mm dia) or equivalant) and swan neck pillar tap complete all as specified and directed.
M&L for chequered cement concrete tiles 250mm x 250mmx 25mm thick, set jointed and pointed in cement slurry in floors with grey cement and pigments including 15mm thick screed bed in CM 1:6 complete all as directed
S&F in repair 10mm thick plain edge moulded cornor glass shelf fix with bracket of 300 mm wide complete all as specified and directed.
S&F in repair for shower rose brass chromium plated without swivel joints, 125 mm in size including fixing to steel pipe complete all as specified and directed.
S&F in repair PVC (SWR) Nahani trap 75 mm bore, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) floor trap 75 mm bore, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair Bib taps , cast copper alloy screwed down high pressure with crutch or butter fly handle fancy type long body CP for 15mm dia bore GI Pipe or for brass ferrule and fixed complete all as specified .
S&F in repair Stop valves, fancy type chromium plated ISI marked , cast copper alloy, screwed down high pressure for 15 mm bore dia GI tubing pipe, high pressure, with crutch butter fly handle complete all as specified
S&F in repair Stop valves fancy type chromium plated with long shank and cup (concealed type) Stop valves, ISI marked , cast copper alloy, screwed down high pressure for 15 mm bore dia GI tubing pipe, high pressure, with crutch butter fly handle complete all as specified
S&F in repair 150 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
Taking down eaves gutters and rain water pipes (any size 75mm to 110mm of any pattern) ,of any description and in any position, including all fittings , heads, shoes, bends, swan necks, etc., (measured overall as fixed along the centre line over fittings and accessories)complete all as specified.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointsfixed on walls complete all as specified and directed
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointsfixed on walls complete all as specified and directed
S&F PVC (SWR) bends, 110 mm bore, any radius with access door complete all as specified and directed.
S&F PVC (SWR) bends, 75 mm bore, any radius with access door complete all as specified and directed.
S&F PVC (SWR) Junction, single, (single T) equal or unequal with access door, 110mm bore, complete all as specified and directed.
S&F PVC (SWR) Junction, single, (single T) equal or unequal with access door, 75 mm bore, complete all as specified and directed.
M&L for PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
M&L for PVC (SWR) vent cowl, 75 mm bore complete all as specified and directed.
Taking up or down existing unserviceable mild steel water tubing and connections 15mm dia, any grade, of any description or in any position including fittings and S&F (concealed / open) 16mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Taking up or down existing unserviceable mild steel water tubing and connections 20mm dia, any grade, of any description or in any position including fittings AND S&F (concealed / open) 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Taking up or down existing unserviceable mild steel water tubing and connections 25mm dia, any grade, of any description or in any position including fittings AND S&F (concealed / open) 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
Taking up or down existing unserviceable mild steel water tubing and connections 25/40mm dia, any grade, of any description or in any position including fittings AND S&F (concealed / open) 40mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
M & L for Preparation of new painted surface of wood and wood based material any description and in any position over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of new painted surface of steel and iron surface of any description and in any position over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of redoxide primer all as specified and directed.
S&F in repair stainless steel grating 150 x150mm size over floor trap anti cockros all as approved sample all as specified and directed.
S&F in repairs for 15mm bore Pillar taps of fancy type, cast copper alloy with capstan heads chromium plated screwed down high pressure with long swan shanks and fly nuts screwed for iron pipe complete all as specified and directed.
S&F in repair soap dish & holder , colour chrome, brass holder fittings fancy type complete all as specified and directed
S&F in Repair anodised aluminium 20mm dia,D type, 60 cm longTubular towel rail complete all as specified and directed
Taking down existing wire mesh of any discription and in any position and supplying and fixing Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm (weight not less than 600 gms/per sqm) and fixed with aluminium wire staples, wooden beads etc complete all as specified and directed
M&L for machine cut kota stone slab 20-25 mm thick as in floor laid and jointed with grey cement slurry mixed with pigment to match with the shade including rubbing and polishing over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in cooking plateform, Jambs cill and like set in cement mortar (1:4) inlcuding pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite including rounding of exposed edges of slab smoothly and polished complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in foundations, fillings and mass concrete etc complete all as specified and as directed.
Excavation in trenches in soft / loose soil not exceeting 1.5 Mtr wide and not exceding 1.5 Mtr in depth and getting out for taking out / laying of cables, erection of poles / strut / stays etc and not exceeding 10 sqm on plan complete all as specified and directed.
Returning, filling in the any type of soil including spreading, levelling, watering and ramming in layers not exc. 25 cms complete all as specified and directed.
Removing excavated material of any type of soil not exceeding 50 Mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed. (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I).
Supply & Laying un-reinforced precast concrete cable cover type-1 Class IV, size of 250 mm x 150 mm x 40 mm laid dry in trenches for under groung cable protection complete all as specifed and directed.
Taking down carefully copper/aluminium point wiring (light,fan,socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody ot for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for point wiring for One light/fan/exhaust fan/buzzer point controlled by one,one way switch with using 1.5 Sqmm (nominal sectional area) multi stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC casing and capping/PVC Conduit of adequate size fixed on surface with PVC rawl plugs with and including Wooden Board/sunken type pressed steel terminal boxes of required size of not less than 1.6 mm thick factory made and factory painted with top cover 3mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multi-stranded copper conductor 1.5 sqmm size PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit/casing capping complete for one light/fan/exhaust fan point controlled by one; one way switch. NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable brass screws and cup washers
All as per item No. 83 here-in-before but One 3 pin socket out let 5 amp point on the (same board) with other switches.
All as per item No. 83 here-in-before but with 2.5sq mm size FRLS pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board.
S & F ceiling rose, surface bakelite, 65X20mm three terminal complete all as specified and directed. Make : Anchor/Havell's/Legrand
S & F switch piano flush button single pole230 / 250 volts one way 5 Amps Complete all as specified and directed. Make : Anchor/Havell's/Legrand
S & F socket outlet 5 pin 5 Amp, flush type complete all as specified and directed. Make : Anchor/Havell's/Legrand
S & F switch socket combination multi-purpose two in one, 3 pin, 5 and 15 Amp, flush type complete all as specified and directed. Make : Anchor/Havell's/Legrand
S & F in replacement elegantly industrial general purpose box type luminaire, 1x20 Watt, designed box type LED luminaries, CRCA sheet steel housing with white reflector cover fitted to the body with decorative end covers complete with electronic ballast, spring loaded rotor type lamp holders, connected block with and including 01 No LED lamp 20 Watt and all accessories, pre-wired and connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface over and including 2 Nos PVC square box complete all as specified and directed.
S & F in replacement 10 W mirror light having indirect up down light for mirror and as well light application with CCT 6000K, including LED Bulb/Module and Electrical connection with 3 core flexible wire of appropriate size from ceiling rose to the tubelight fitting, all as specified and directed.
Supply and fix Exhaust fan, steel body, steel body AC Single phase 230 V of size 300 mm sweep with blades, and frame and louvers complete all as specified and directed
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed
Supplying & fixing lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings incl 01 No LED lamp 14/15 watt 6500 K complete all as specified and directed.
Supply and lay pipe galvanized, "Medium class", including fittings 25 mm (1.0") dia complete all as specified and directed
Supply and fix PPR Gate valves (brass insert) of 25 mm bore complete all as specified and directed
Taking down carefully aluminium/copper submain wiring /cable including steel/PVC conduit complete and making good disturbed surfaces of walls, floors etc and M & L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating 1100 Volts drawn in and including surface casing and caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 2.5 Sqmm as earth continuity conductor Complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, earthed of size 10 sqmm, 2 core laid in trenches / poles / fixed to walls etc complete all as specified and directed.
Taking down carefully MCBs, distribution boards/main switches of any type and size for replacement and Supply & fix for sheet metal enclosure powder painted for MCB DB TPN 4 way double door with IP-43 protection with Din rail and busbar Complete all as specified and directed.
Taking down carefully MCBs, distribution boards/main switches of any type and size for replacement and Supply & fix for sheet metal enclosure powder painted for MCB DB SPN 8 way double door with IP-43 protection with Din rail and busbar Complete all as specified and directed.
Supply & fix in repair MCB SP 230V 'C' series 6-32 Amps 10 KA rating ISI marked and connecting Complete all as specified and directed.
Supply & fix in repair MCB SPN 230V 'C' series 6-40Amps 10 KA rating ISI marked and connecting Complete all as specified and directed.
Supply & fix in repair MCB TPN 415V 'C' series 63 Amps 10 KA rating ISI marked and connecting Complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. (The Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’. The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering pipe.) Note :- The retreived materials have been mentioned in the Sch of credit in the tender documents in pdf form. The amount of Sch of credit will be deducted offline from the amount of BOQ at the time of acceptance.
machine vision plus
Khodiyar Construction
M/S S. SINGH TRADERS
divyarsh entrprise
M/s Bombay Novelty Stores
ASHAPURA CONTRACTOR
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .