Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAdmitted-Fee/PreQual/Technical/Finance | ₹28.4 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹29.2 L+₹87,822.73 (3.10%)Admitted-Fee/PreQual/Technical/Finance | ₹29.2 L+₹87,822.73 (3.10%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹30.2 L+₹1.9 L (6.53%)Admitted-Fee/PreQual/Technical/Finance VILLAGE AND POST OFFICE BHILKOT GARUD DISTRICT BAGESHWAR | ₹30.2 L+₹1.9 L (6.53%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹31.1 L+₹2.7 L (9.53%)Admitted-Fee/PreQual/Technical/Finance BAGESHWAR UTTARAKHAND UT | BAGESHWAR | UTTARAKHAND | 263619 | ₹31.1 L+₹2.7 L (9.53%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | L5₹31.9 L+₹3.6 L (12.6%)Admitted-Fee/PreQual/Technical/Finance | ₹31.9 L+₹3.6 L (12.6%) | L5 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | PRITAM CONSTRUCTION L3 | Navin Singh Parihar L4 | SHAILENDR SINGH FARSWAN L5 | NANDAN SINGH MEHRA L2 | DAYA KRISHNA JOSHI L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in hill side cutting / defect cutting in all type of soil & rocks etc as met site including lead 30 m and lift upto 1.50 m as per plan L-section including disposal or surplus excavated materials and debris as per direction of Engineer in chrgen | 1 | job | 10,000 ₹10,000 | 25,000 ₹25,000 | 61,591 ₹61,591 | 1,349.58 ₹1,349.58 Lowest | 40,000 ₹40,000 |
| 2.00C/O 1 m span scupper with Construction of 1 m span scupper | ||||||||
| 2.01 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction | 217.74 | cum | 150 ₹32,661 | 275 ₹59,878.5 | 342 ₹74,467.08 | 60 ₹13,064.4 Lowest | 100 ₹21,774 |
| 2.02 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6 | 15.75 | cum | 4,500 ₹70,875 Lowest | 4,996.05 ₹78,687.79 | 4,877 ₹76,812.75 | 5,200 ₹81,900 | 4,600 ₹72,450 |
| 2.03 | Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704,1202 & 1203 of MORD Specifiction | 44.64 | cum | 1,800 ₹80,352 Lowest | 1,926.86 ₹86,015.03 | 1,928 ₹86,065.92 | 1,900 ₹84,816 | 1,800 ₹80,352 Lowest |
| 2.04 | Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Random rubble masonry In cement mortar (1:5) | 63.93 | cum | 3,000 ₹1,91,790 Lowest | 3,485.83 ₹2,22,849.11 | 3,362 ₹2,14,932.66 | 3,900 ₹2,49,327 | 3,000 ₹1,91,790 Lowest |
| 2.05 | Providing concrete for plain/ reinforced concrete in open foundations complete as per
drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 Nominal mix (1:2:4) | 2.81 | cum | 5,400 ₹15,174 | 5,000 ₹14,050 Lowest | 5,532 ₹15,544.92 | 5,500 ₹15,455 | 5,000 ₹14,050 Lowest |
| 2.06 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, inbreast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction | 16.2 | Tonne | 2,700 ₹43,740 Lowest | 3,359.11 ₹54,417.58 | 3,360 ₹54,432 | 3,000 ₹48,600 | 3,000 ₹48,600 |
| 2.07 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (The reinforcement steel shall be procured from original (primary) steel producers as per clause no. 2011.3.1 of MORD specifications (First revision'2014) and IS 1786:2008 clause no. 1.6) | 10.92 | quintal | 8,400.42 ₹91,732.59 | 7,140.35 ₹77,972.62 | 7,144 ₹78,012.48 | 8,000 ₹87,360 | 6,000 ₹65,520 Lowest |
| 2.08 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (For height upto 5 m) R.C.C. grade M 25 | 13.02 | cum | 5,500 ₹71,610 Lowest | 6,591.49 ₹85,821.2 | 6,594 ₹85,853.88 | 7,200 ₹93,744 | 5,500 ₹71,610 Lowest |
Tender Value
Refer Docs
EMD Value
₹89,000
Closing Date
27 Aug 2026, 10:30 amClosed
EE PD PWD BAGESHWAR
EE PD PWD BAGESHWAR
improvement work of garur Devnai chaukhutiya motor road in km 1 2 and 3.(remaining work)
2026_pwd_98603_1
1872/23 AC date 29.07.2026
Open Tender
Civil Works - Roads
Item Rate
270 days
EE PD PWD BAGESHWAR
As per tender
2 documents required · 2 mandatory
₹3,540
EE PD PWD BAGESHWAR
₹89,000
27 Aug 2026
5 Aug 2026
27 Aug 2026
5 Aug 2026
27 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in hill side cutting / defect cutting in all type of soil & rocks etc as met site including lead 30 m and lift upto 1.50 m as per plan L-section including disposal or surplus excavated materials and debris as per direction of Engineer in chrgen | 1 | job | - | - |
| 2C/O 1 m span scupper with Construction of 1 m span scupper | |||||
| 2.01 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction | 217.74 | cum | - | - |
| 2.02 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6 | 15.75 | cum | - | - |
| 2.03 | Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704,1202 & 1203 of MORD Specifiction | 44.64 | cum | - | - |
| 2.04 | Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Random rubble masonry In cement mortar (1:5) | 63.93 | cum | - | - |
| 2.05 | Providing concrete for plain/ reinforced concrete in open foundations complete as per
drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 Nominal mix (1:2:4) | 2.81 | cum | - | - |
| 2.06 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, inbreast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction | 16.2 | Tonne | - | - |
| 2.07 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 (The reinforcement steel shall be procured from original (primary) steel producers as per clause no. 2011.3.1 of MORD specifications (First revision'2014) and IS 1786:2008 clause no. 1.6) | 10.92 | quintal | - | - |
| 2.08 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (For height upto 5 m) R.C.C. grade M 25 | 13.02 | cum | - | - |
stage.html
html • 0.02 MB
finance_116335.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.02 MB
file.pdf
Tender Documents • 2.28 MB
BOQ_116335.xls
BOQ • 0.31 MB
Corrigendum.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .