Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAdmitted-Finance PLOT NO EL 205 MIDC MAHAPE TTC INDUSTRIAL AREA NAVI MUMBAI THANE MAHARASHTRA 400710 | THANE | MAHARASHTRA | 400710 | ₹2.1 Cr | L1 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
22 Feb 2020, 3:00 pmClosed
Cdr Vikram S Manral
Fleet Maintenance Unit, C/o Fleet Mail Office, Naval Dockyard, Visakhapatnam-14
Repair Rate Contract for Integrated Multimedia Communication System (IMCOS) fitted onboard INS Shakti of ENC
2020_NAVY_320660_1
PC/301/IMCOS/SKT dated 31 Jan 20
Single
Marine Services
Buy
1095 days
Fleet Maintenance Unit, Visakhapatnam
As per RFP
5 documents required · 5 mandatory
₹0
₹1.3 L
Yes
11 Jun 2020
31 Jan 2020
24 Feb 2020
31 Jan 2020
22 Feb 2020
31 Jan 2020
31 Jan 2020 - 22 Feb 2020
Amount
First Year
Services
Public Address and General Alarm System (PAGA System)
Controller Unit (IMCOS 3002). Fault Diagnosis and Rectification. Remove/ Repair/ Replace and test for normal operation.
Amplifier (IMCOS 150). Fault Diagnosis and Rectification. Remove/ Repair/ Replace and test for normal operation.
Program Logic Control (IMCOS 3000). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Control Panel (IMCOS 7001). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Control Panel (IMCOS 7015). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Ceiling Loudspeaker Aluminum Dome (IMCOS 6801/A1). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Toilet Alarm Loudspeaker (IMCOS 6899). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Water Tight Horn Loud Speaker. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Alarm Panel. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Audio Visual Column. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Relay Unit and Junction Box for Audio Visual Column. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Fire System. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Car Stereo System. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Music Amplifier (IMCOS 150). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Volume Control (IMCOS 6872). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Digital Memory Bank. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Gyro Stabilised Satellite TV System
Satellite Antenna Control. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Stabilised Satellite Antenna Unit. Fault Diagnosis and Rectification. Remove of defective units for Repair/Replace and test for normal operation.
8-Port Digital Matrix Switching Unit. Fault Diagnosis and Rectification. Repair/ Replace and test for normal operation.
AM/ FM TV Amplifier with Centralised Cable TV Distribution System. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine checks of all connectors and replacement of connectors if required and test for normal operation.
Sound Power Telephone System
Control PCB Sound Power Telephone. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Defect on Incoming/ Outgoing call connected to the network according to the network group list. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine Maintenance of Complete Sound Power Telephone System. Checking of complete system, repair and test for normal operation
Defect on A/V Visual Repeaters or Incoming Call NO Free Contact Group List. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation
Automatic Telephone Exchange
Power Supply. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Defect Identification/ diagnosis of all type of telephone instruments. Remove/Repair/Replace.
Microprocessor PCB. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Extension Card. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Shore Connection. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Interface with Main Broadcast. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine maintenance of complete telephone exchange.
Installation, Commissioning/ Re-commissioning. STW, commissioning of system and test for normal operation.
Digital Clock System
Master Clock. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Decorative Clock. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine maintenance of complete clock system
Talkback System
Program logic control (IMCOS 3000). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Amplifier (IMCOS 8230). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Pre-Amplifier (IMCOS 8210). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Control Panel (IMCOS 7015/1L). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Loudspeaker (IMCOS 6811). Fault diagnosis and rectification. Replace and test for normal Operation.
Waterproof Reversible Substation (IMCOS 6910/X). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Spares
Public Address and General Alarm System (PAGA System)
PCB PA/ TB Controller
PCB Pre Amplifier
Power Amplifier
PCB Change over
PCB Line Exchange Relay
PCB Tone generator
Relay PCB for TB Sub section
PCB Backup Audio Switcher
PCB Power Auxiliary Relays
PCB Amplifier
PCB Remote Control
Water Proof Loud speaker IP-56
Bathroom Alarm Loud Speaker
Ceiling Loud Speaker
Hand Held Microphone
PCB Micro Controller
PCB for Controller
PCBs for Main Control Panel
Ceiling Loud Speaker
Gyro Stabilised Satellite TV System
Azimuth Motor Assy
Cross Motor Assy
Elevation Motor Assy
PCU Board
Sensor Board
Level Case Stage Motor Assy
Encoder (including HALL Sensor)
Potentiometer and skew Motor
KA-70 Antenna Control Unit (ACU)
Quattro LNB
RX Cable (LNB Cable)
AM/FM Radio Antenna
Combined Radio TV Socket
1 Way Splitter 16 DB
1 Way Splitter 12 DB
2 Way Splitter 16 DB
Remote Volume Control
Sound Power Telephone System
Multi way SPT 24 Lines Wall Mounting
Multi way SPT 24 Lines Wall Mounting HS
Multi way SPT 24 Lines Wall Console Mounting
Relay Box 220V AC
Rotating Lamp Amber (220V AC)
Junction Box
Junction Box
Automatic Telephone Exchange
Automatic Telephone
Water Proof Automatic Telephone Wall Mounting
Water Proof Automatic Telephone Wall Mounting complete with Handset
Portable Automatic Telephone
Socket for Automatic Analog Telephone
Relay Box with Audio Visual Device
Socket for Automatic Telephone
Telephone Exchange (Upgraded Model)
Digital Clock System
Electric Slave Clock decorative type
Electric Slave Clock wall mounting
Digital Clock Panel
Electric Slave Clock
Digital Clock System
Program Logic Control
Amplifier
Pre Amplifier
Remote Control Panel PCB
Bi Directional Speaker
Water Proof reversible Sub Station
Second Year
Services
Public Address and General Alarm System (PAGA System)
Controller Unit (IMCOS 3002). Fault Diagnosis and Rectification. Remove/ Repair/ Replace and test for normal operation.
Amplifier (IMCOS 150). Fault Diagnosis and Rectification. Remove/ Repair/ Replace and test for normal operation.
Program Logic Control (IMCOS 3000). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Control Panel (IMCOS 7001). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Control Panel (IMCOS 7015). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Ceiling Loudspeaker Aluminum Dome (IMCOS 6801/A1). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Toilet Alarm Loudspeaker (IMCOS 6899). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Water Tight Horn Loud Speaker. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Alarm Panel. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Audio Visual Column. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Relay Unit and Junction Box for Audio Visual Column. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Fire System. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Car Stereo System. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Music Amplifier (IMCOS 150). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Volume Control (IMCOS 6872). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Digital Memory Bank. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Gyro Stabilised Satellite TV System
Satellite Antenna Control. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Stabilised Satellite Antenna Unit. Fault Diagnosis and Rectification. Remove of defective units for Repair/Replace and test for normal operation.
8-Port Digital Matrix Switching Unit. Fault Diagnosis and Rectification. Repair/ Replace and test for normal operation.
AM/ FM TV Amplifier with Centralised Cable TV Distribution System. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine checks of all connectors and replacement of connectors if required and test for normal operation.
Sound Power Telephone System
Control PCB Sound Power Telephone. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Defect on Incoming/ Outgoing call connected to the network according to the network group list. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine Maintenance of Complete Sound Power Telephone System. Checking of complete system, repair and test for normal operation
Defect on A/V Visual Repeaters or Incoming Call NO Free Contact Group List. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation
Automatic Telephone Exchange
Power Supply. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Defect Identification/ diagnosis of all type of telephone instruments. Remove/Repair/Replace.
Microprocessor PCB. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Extension Card. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Shore Connection. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Interface with Main Broadcast. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine maintenance of complete telephone exchange.
Installation, Commissioning/ Re-commissioning. STW, commissioning of system and test for normal operation.
Digital Clock System
Master Clock. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Decorative Clock. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine maintenance of complete clock system
Talkback System
Program logic control (IMCOS 3000). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Amplifier (IMCOS 8230). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Pre-Amplifier (IMCOS 8210). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Control Panel (IMCOS 7015/1L). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Loudspeaker (IMCOS 6811). Fault diagnosis and rectification. Replace and test for normal Operation.
Waterproof Reversible Substation (IMCOS 6910/X). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Spares
Public Address and General Alarm System (PAGA System)
PCB PA/ TB Controller
PCB Pre Amplifier
Power Amplifier
PCB Change over
PCB Line Exchange Relay
PCB Tone generator
Relay PCB for TB Sub section
PCB Backup Audio Switcher
PCB Power Auxiliary Relays
PCB Amplifier
PCB Remote Control
Water Proof Loud speaker IP-56
Bathroom Alarm Loud Speaker
Ceiling Loud Speaker
Hand Held Microphone
PCB Micro Controller
PCB for Controller
PCBs for Main Control Panel
Ceiling Loud Speaker
Gyro Stabilised Satellite TV System
Azimuth Motor Assy
Cross Motor Assy
Elevation Motor Assy
PCU Board
Sensor Board
Level Case Stage Motor Assy
Encoder (including HALL Sensor)
Potentiometer and skew Motor
KA-70 Antenna Control Unit (ACU)
Quattro LNB
RX Cable (LNB Cable)
AM/FM Radio Antenna
Combined Radio TV Socket
1 Way Splitter 16 DB
1 Way Splitter 12 DB
2 Way Splitter 16 DB
Remote Volume Control
Sound Power Telephone System
Multi way SPT 24 Lines Wall Mounting
Multi way SPT 24 Lines Wall Mounting HS
Multi way SPT 24 Lines Wall Console Mounting
Relay Box 220V AC
Rotating Lamp Amber (220V AC)
Junction Box
Junction Box
Automatic Telephone Exchange
Automatic Telephone
Water Proof Automatic Telephone Wall Mounting
Water Proof Automatic Telephone Wall Mounting complete with Handset
Portable Automatic Telephone
Socket for Automatic Analog Telephone
Relay Box with Audio Visual Device
Socket for Automatic Telephone
Telephone Exchange (Upgraded Model)
Digital Clock System
Electric Slave Clock decorative type
Electric Slave Clock wall mounting
Digital Clock Panel
Electric Slave Clock
Digital Clock System
Program Logic Control
Amplifier
Pre Amplifier
Remote Control Panel PCB
Bi Directional Speaker
Water Proof reversible Sub Station
Third Year
Services
Public Address and General Alarm System (PAGA System)
Controller Unit (IMCOS 3002). Fault Diagnosis and Rectification. Remove/ Repair/ Replace and test for normal operation.
Amplifier (IMCOS 150). Fault Diagnosis and Rectification. Remove/ Repair/ Replace and test for normal operation.
Program Logic Control (IMCOS 3000). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Control Panel (IMCOS 7001). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Control Panel (IMCOS 7015). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Ceiling Loudspeaker Aluminum Dome (IMCOS 6801/A1). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Toilet Alarm Loudspeaker (IMCOS 6899). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Water Tight Horn Loud Speaker. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Alarm Panel. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Audio Visual Column. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Relay Unit and Junction Box for Audio Visual Column. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Fire System. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Car Stereo System. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Music Amplifier (IMCOS 150). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Volume Control (IMCOS 6872). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Digital Memory Bank. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Gyro Stabilised Satellite TV System
Satellite Antenna Control. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Stabilised Satellite Antenna Unit. Fault Diagnosis and Rectification. Remove of defective units for Repair/Replace and test for normal operation.
8-Port Digital Matrix Switching Unit. Fault Diagnosis and Rectification. Repair/ Replace and test for normal operation.
AM/ FM TV Amplifier with Centralised Cable TV Distribution System. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine checks of all connectors and replacement of connectors if required and test for normal operation.
Sound Power Telephone System
Control PCB Sound Power Telephone. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Defect on Incoming/ Outgoing call connected to the network according to the network group list. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine Maintenance of Complete Sound Power Telephone System. Checking of complete system, repair and test for normal operation
Defect on A/V Visual Repeaters or Incoming Call NO Free Contact Group List. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation
Automatic Telephone Exchange
Power Supply. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Defect Identification/ diagnosis of all type of telephone instruments. Remove/Repair/Replace.
Microprocessor PCB. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Extension Card. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Shore Connection. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Interface with Main Broadcast. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine maintenance of complete telephone exchange.
Installation, Commissioning/ Re-commissioning. STW, commissioning of system and test for normal operation.
Digital Clock System
Master Clock. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Decorative Clock. Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Routine maintenance of complete clock system
Talkback System
Program logic control (IMCOS 3000). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Amplifier (IMCOS 8230). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Pre-Amplifier (IMCOS 8210). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Remote Control Panel (IMCOS 7015/1L). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Loudspeaker (IMCOS 6811). Fault diagnosis and rectification. Replace and test for normal Operation.
Waterproof Reversible Substation (IMCOS 6910/X). Fault Diagnosis and Rectification. Remove/Repair/Replace and test for normal operation.
Spares
Public Address and General Alarm System (PAGA System)
PCB PA/ TB Controller
PCB Pre Amplifier
Power Amplifier
PCB Change over
PCB Line Exchange Relay
PCB Tone generator
Relay PCB for TB Sub section
PCB Backup Audio Switcher
PCB Power Auxiliary Relays
PCB Amplifier
PCB Remote Control
Water Proof Loud speaker IP-56
Bathroom Alarm Loud Speaker
Ceiling Loud Speaker
Hand Held Microphone
PCB Micro Controller
PCB for Controller
PCBs for Main Control Panel
Ceiling Loud Speaker
Gyro Stabilised Satellite TV System
Azimuth Motor Assy
Cross Motor Assy
Elevation Motor Assy
PCU Board
Sensor Board
Level Case Stage Motor Assy
Encoder (including HALL Sensor)
Potentiometer and skew Motor
KA-70 Antenna Control Unit (ACU)
Quattro LNB
RX Cable (LNB Cable)
AM/FM Radio Antenna
Combined Radio TV Socket
1 Way Splitter 16 DB
1 Way Splitter 12 DB
2 Way Splitter 16 DB
Remote Volume Control
Sound Power Telephone System
Multi way SPT 24 Lines Wall Mounting
Multi way SPT 24 Lines Wall Mounting HS
Multi way SPT 24 Lines Wall Console Mounting
Relay Box 220V AC
Rotating Lamp Amber (220V AC)
Junction Box
Junction Box
Automatic Telephone Exchange
Automatic Telephone
Water Proof Automatic Telephone Wall Mounting
Water Proof Automatic Telephone Wall Mounting complete with Handset
Portable Automatic Telephone
Socket for Automatic Analog Telephone
Relay Box with Audio Visual Device
Socket for Automatic Telephone
Telephone Exchange (Upgraded Model)
Digital Clock System
Electric Slave Clock decorative type
Electric Slave Clock wall mounting
Digital Clock Panel
Electric Slave Clock
Digital Clock System
Program Logic Control
Amplifier
Pre Amplifier
Remote Control Panel PCB
Bi Directional Speaker
Water Proof reversible Sub Station
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .