Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹65,000+₹1,600 (2.52%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹66,300+₹2,900 (4.57%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
Closing Date
8 Jan 2021, 1:00 pmClosed
Maj GS Pandey, GE (AF) Bhuj
GE (AF) Bhuj, Bhuj-Kutch, PIN-370001
Provn of Cooking Range at Ops Location (Khavda) 171 SU at AF Stn Bhuj
2020_MES_407958_1
3020/eQ/56/20-21/E3
Limited
Job Works
Item Rate
30 days
GE (AF) Bhuj
The firm must be registered with HQ CWE (AF) Bhuj as approved supplier to carryout general order supply and job work
1 document required · 1 mandatory
₹0
Exempted
22 Feb 2021
30 Dec 2020
9 Jan 2021
30 Dec 2020
8 Jan 2021
30 Dec 2020
Amount
1. Supply and fix electric driven chimney wall mounted type with stainless steel body with Led light lamp single phase 230V AC, having 1250 m3/Hr discharge capacity all as directed by Engr-in-Charge. (Each – 1). 2. M and L for point wiring complete with 2.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI marked drawn through and including PVC CASING & CAPPING INCLUDING accessories etc including fixed to wall/ceiling including provn of 2.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with wooden board (1st class teak wood) with laminated sheet top cover, 3mm thick for one 3 pin, 15 Amps socket out let on independent board complete as specified and directed. (Point – 1). 3. S&F switch socket combination 2 in 1, 6 pin 5 and 15 Amp flush type universal all as directed/ specified. (Each -1). 4. S&F double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 4 ways with 200 Amp rated bus bar 415 volts powder coated all as specified (Make : Havell's, L&T, Standard, Crompton/Indoasian/Polycab) (Each – 1). 5. S&F in replacement of isolators, MCBs, etc. In distribution board of the following rating and capacities (Make : Havell's, L&T, Standard, Crompton/Indoasian/Polycab) :- (a) MCB SPN of 240 volts 20/32/40 Amps Capacity, 'C' series, 10 KA. (Each -1). (b) MCB SP of 240 volts 5-32 Amps Capacity, 'C' series, 10 KA. (Each -2).
6. Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2core. (Each – 60). 7. Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and all as directed. (Cum – 7). 8. M & L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. (Cum – 3). 9. Supplying and laying un-reinforced precast concrete cable cover class LV, type - 2, flat, size 300x 180 x 40 mm all as specified and directed. (Each – 150). 10. Returning and filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm thick all as specified and directed by Engr-in-Charge. (Cum – 5). 11. Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified. (Cum – 4). 12. S&F 32mm bore Galvanised iron tubes light grade for cable protection complete all as specified and directed by Engineer-in-Charge. (RM - 10). 13. M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI strip 25x4mm as earth lead up to 7.5 mtr length by means of bolts, nuts check muts and washers etc. of galvanised iron or steel all as shown in electrical plate No. 3 including provn of GI protection pipe light grade of 32mm bore upto 7.5m length and connected earth strip to earthing test point all as shown in electrical plate No. 3 of SSR Part - I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (rein forced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 20mm bore medium grade, wire mesh and lugs test point etc. (Each Set – 1)
Hariom Traders
Bhavik Construction
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_455535.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .