Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAdmitted-Finance 15 NEW IDDGAH BUILDINGS NH BARAMULLA BARAMULLA JAMMU KASHMIR 193101 | BARAMULLA | JAMMU AND KASHMIR | 193101 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NSCOO ENGINEERING PRIVATE LIMITED L1 |
|---|---|---|---|---|
| 1.00 | SITC of ultra-sonic OPEN Channel Flow Meter
Current flow: 0.1L/Second to 10m³/Second
Flow accuracy: ± (1-3)% (according to water measuring o weir)
Max level: 8 meters
Blind area: ≤0.4 meters
Level accuracy: ±0.3% (in 3 meters)
Resolution: 1 mm
Instrument protection: IP65
Cumulative flow: Can be queried by year, month, day, hour
Output signal: (4-20) mA (instantaneous flow) and Rs485 • (instantaneous and cumulative flow)
Working temperature: -20°C to 55°C
Power supply: AC 220V 50Hz, DC 12-36V 3W
Separate Display for Open Channel With 50mtr cable
Range : Programmable
Display : 2" LED Display
Input : 4-20 mA
Supply : 220 V AC | 1 | Job | 1,07,500 ₹1,07,500 Lowest |
Tender Value
₹1 L
EMD Value
₹2,000
Closing Date
25 Nov 2025, 4:00 pmClosed
Executive Engineer
Executive Engineer GD LJHP
Supply installation testing and commissioning of automatic level measurement system at Barrage Intake of LJHP BARAMULLA
2025_SPDC_291052_2
NIT no. 29 of 2025-26 dated 07-10-2025
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
Gantmulla Baramulla
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
Chief Pay And Accounts Officer Baramulla
₹2,000
Yes
13 Dec 2025
11 Nov 2025
27 Nov 2025
11 Nov 2025
25 Nov 2025
11 Nov 2025
Amount
SITC of ultra-sonic OPEN Channel Flow Meter Current flow: 0.1L/Second to 10m³/Second Flow accuracy: ± (1-3)% (according to water measuring o weir) Max level: 8 meters Blind area: ≤0.4 meters Level accuracy: ±0.3% (in 3 meters) Resolution: 1 mm Instrument protection: IP65 Cumulative flow: Can be queried by year, month, day, hour Output signal: (4-20) mA (instantaneous flow) and Rs485 • (instantaneous and cumulative flow) Working temperature: -20°C to 55°C Power supply: AC 220V 50Hz, DC 12-36V 3W Separate Display for Open Channel With 50mtr cable Range : Programmable Display : 2" LED Display Input : 4-20 mA Supply : 220 V AC
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
TDforSITCOFAUTOMATICLEVELMEASUREMENTSYSTEMATINTAKEOFBARRAGE.pdf
Tender Documents • 1.39 MB
BOQ_953376.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .