Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.7 LAccepted-AOC | ₹59.7 L | L1 | Accepted-AOC Since, SP Enterprises became L1 |
| 2 | L2₹60.2 LRejected-Finance K 11 MAHIPALPUR NEW DELHI 110037 | NEW DELHI | DELHI | 110037 | ₹60.2 L | L2 | Rejected-Finance since the agency not L1 |
| 3 | L3₹61.1 LRejected-Finance NO 626 6TH MAIN ROAD METRO GRAND CITY MEHTA NAGAR KUNDRATHUR CHENNAI 600 069 | KANCHIPURAM | TAMIL NADU | 600069 | ₹61.1 L | L3 | Rejected-Finance since the agency not L1 |
| 4 | L4₹64.5 LRejected-Finance | ₹64.5 L | L4 | Rejected-Finance since the agency not L1 |
| 5 | L5₹77.0 LRejected-Finance | ₹77.0 L | L5 | Rejected-Finance since the agency not L1 |
| Sl No | Description | Qty | Unit | M/s Raghava Project Constructions Pvt. Ltd. L5 | THUNGA BROTHERS L3 | M/S SAI VISHNU CONSTRUCTIONS L4 | Parikh Kashyap Indulal L6 | BALVIR SINGH AND SONS L2 | SP ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Removal of old paint Markings on Runway / Apron area using Water blasting Cum Vacuuming System With Suitable Pressure without disturbing the existing surface including disposal of rubbish etc. and as per the direction of Engineer In Charge | 6,875 | Sqm | 445 ₹30.6 L | 153.99 ₹10.6 L | 90 ₹6.2 L | 356 ₹24.5 L | 135 ₹9.3 L | 285 ₹19.6 L |
| 2.00 | Painting of Taxiway, /Apron marking with retro reflective road marking paint of superior make of Apco track/ Fast track WBR 3427 of Asian paint or equivalent with Air/ Airless spray applications including the application of high index glass beads (TTB 1325 type III and having refractive index 1.90)of Potters make or equivalent . The painting shall be done for the new markings on Taxiway /Apron as per the recommended dimensions & as per the layout drawings and as per direction of Engineer -in-charge .The existing surface shall be cleaned thoroughly off dirt, dust, scales, oil grease etc. before application of the paint. (The painting to be applied should have a single coat coverage of @0.50 kg per sqm for paint and 500 grms per sqm for glass beads)
A)One or more coats. | 8,003 | Sqm | 427 ₹34.2 L | 459.99 ₹36.8 L | 540 ₹43.2 L | 461 ₹36.9 L | 457 ₹36.6 L | 325 ₹26.0 L |
| 3.00 | Repairing of concrete edges/corners by preparing the existing surface of concrete floor on Apron area by following process.
A) Scarification and cleaning by wire brushing etc. to remove all foreign contaminants, loosely adhered cementitious layer, oil etc. to expose clean sound base concrete substrate.
B) Providing and Applying two component epoxy resin based primer, FOSROC or equivalent approved make on the prepared surface.
C) Providing and laying of epoxy screed (Fosroc make or equivalent approved Make) after the application of Moisture Insensitive Primer Complete as per direction of Engineer-in-Charge. | 600 | Kg | 320 ₹1.9 L | 612.99 ₹3.7 L | 405 ₹2.4 L | 525 ₹3.1 L | 757 ₹4.5 L | 350 ₹2.1 L |
| 4.00 | Providing and laying in position Polysulphide sealant of approved make conforming to BS-5212-1990 or IS: 11433-1995 in expansion joints including cleaning of existing expansion joints by removing old existing sealant, backer rod etc., grinding & rounding off edges and removing loose materials from the joints, applying 2 coats of approved primer compatible with the brand of Polysulphide and preparing the surface and applying masking tape along the edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. complete as per direction of Engineer in-Charge & particular specifications.
[Note: For purpose of payment, quantity (Length x Width x Depth) of Polysulphide sealant only will be measured.] unit cm3
i) Expansion Joints of size 25 mm wide and 10 mm deep over 30 mm dia closed-cell Polyethylene foam back-up rod, as per manufacturers specifications and sketch at Appendix-‘A’. | 1,24,450 | Cu Cm | 1.3 ₹1.6 L | 1.17 ₹1.5 L | 1.8 ₹2.2 L | 1.5 ₹1.9 L | 1.15 ₹1.4 L | 2.5 ₹3.1 L |
| 5.00 | Providing and laying in position Polysulphide sealant of approved make conforming to BS-5212-1990 or IS: 11433-1995 in construction/dummy joints including cleaning of existing construction & dummy joints by removing old existing sealant, backer rod etc., grinding & rounding off edges and removing loose materials from the joints, applying 2 coats of approved primer compatible with the brand of Polysulphide and preparing the surface and applying masking tape along the edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. complete as per direction of Engineer in-Charge & particular specifications. 2 [Note: For purpose of payment, quantity (Length x Width x Depth) of Polysulphide sealant only will be measured.] unit cm3
i)Construction Joints of size 10 mm wide and 10 mm deep over 12 dia closed-cell Polyethylene foam back-up rod, as per manufacturers specifications and sketch at Appendix-‘A’.
ii)Dummy Joints of size 10 mm wide and 10 mm deep over 12 mm dia closed-cell Polyethylene foam back-up rod, as per manufacturer’s specifications and sketch at Appendix-‘A’. | 6,89,070 | Cu Cm | 1.2 ₹8.3 L | 1.17 ₹8.1 L | 1.44 ₹9.9 L | 1.75 ₹12.1 L | 1.05 ₹7.2 L | 1.25 ₹8.6 L |
| 6.00 | Conducting detail survey using Total station taking all existing features like boundaries with measurements and marking of proposed points on Apron as per drawings provided and preparing drawings & supply of soft and hard copies. | 4 | per Day | 10,000 ₹40,000 | 12,699.99 ₹50,799.96 | 12,600 ₹50,400 | 12,000 ₹48,000 | 29,557 ₹1.2 L | 6,000 ₹24,000 |
Tender Value
₹85.7 L
EMD Value
₹1.7 L
Closing Date
3 Apr 2024, 6:00 pmClosed
AGM civil
AGM civil civil Engg division Vijayawada airport
Providing new markings as per reorientation of existing apron including removal of old markings and associated works at Vijayawada airport
2024_AAI_188480_1
AAI/VIJ/DGM(E-C)
Open Tender
Civil Works
240 days
vijayawada
AS per tender document
4 documents required · 4 mandatory
₹1,180
₹1.7 L
20 Feb 2026
11 Mar 2024
4 Apr 2024
11 Mar 2024
3 Apr 2024
11 Mar 2024
11 Mar 2024 - 18 Mar 2024
Amount
Removal of old paint Markings on Runway / Apron area using Water blasting Cum Vacuuming System With Suitable Pressure without disturbing the existing surface including disposal of rubbish etc. and as per the direction of Engineer In Charge
Painting of Taxiway, /Apron marking with retro reflective road marking paint of superior make of Apco track/ Fast track WBR 3427 of Asian paint or equivalent with Air/ Airless spray applications including the application of high index glass beads (TTB 1325 type III and having refractive index 1.90)of Potters make or equivalent . The painting shall be done for the new markings on Taxiway /Apron as per the recommended dimensions & as per the layout drawings and as per direction of Engineer -in-charge .The existing surface shall be cleaned thoroughly off dirt, dust, scales, oil grease etc. before application of the paint. (The painting to be applied should have a single coat coverage of @0.50 kg per sqm for paint and 500 grms per sqm for glass beads) A)One or more coats.
Repairing of concrete edges/corners by preparing the existing surface of concrete floor on Apron area by following process. A) Scarification and cleaning by wire brushing etc. to remove all foreign contaminants, loosely adhered cementitious layer, oil etc. to expose clean sound base concrete substrate. B) Providing and Applying two component epoxy resin based primer, FOSROC or equivalent approved make on the prepared surface. C) Providing and laying of epoxy screed (Fosroc make or equivalent approved Make) after the application of Moisture Insensitive Primer Complete as per direction of Engineer-in-Charge.
Providing and laying in position Polysulphide sealant of approved make conforming to BS-5212-1990 or IS: 11433-1995 in expansion joints including cleaning of existing expansion joints by removing old existing sealant, backer rod etc., grinding & rounding off edges and removing loose materials from the joints, applying 2 coats of approved primer compatible with the brand of Polysulphide and preparing the surface and applying masking tape along the edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. complete as per direction of Engineer in-Charge & particular specifications. [Note: For purpose of payment, quantity (Length x Width x Depth) of Polysulphide sealant only will be measured.] unit cm3 i) Expansion Joints of size 25 mm wide and 10 mm deep over 30 mm dia closed-cell Polyethylene foam back-up rod, as per manufacturers specifications and sketch at Appendix-‘A’.
Providing and laying in position Polysulphide sealant of approved make conforming to BS-5212-1990 or IS: 11433-1995 in construction/dummy joints including cleaning of existing construction & dummy joints by removing old existing sealant, backer rod etc., grinding & rounding off edges and removing loose materials from the joints, applying 2 coats of approved primer compatible with the brand of Polysulphide and preparing the surface and applying masking tape along the edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. complete as per direction of Engineer in-Charge & particular specifications. 2 [Note: For purpose of payment, quantity (Length x Width x Depth) of Polysulphide sealant only will be measured.] unit cm3 i)Construction Joints of size 10 mm wide and 10 mm deep over 12 dia closed-cell Polyethylene foam back-up rod, as per manufacturers specifications and sketch at Appendix-‘A’. ii)Dummy Joints of size 10 mm wide and 10 mm deep over 12 mm dia closed-cell Polyethylene foam back-up rod, as per manufacturer’s specifications and sketch at Appendix-‘A’.
Conducting detail survey using Total station taking all existing features like boundaries with measurements and marking of proposed points on Apron as per drawings provided and preparing drawings & supply of soft and hard copies.
BALVIR SINGH AND SONS
THUNGA BROTHERS
M/S SAI VISHNU CONSTRUCTIONS
M/s Raghava Project Constructions Pvt. Ltd.
Parikh Kashyap Indulal
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid