Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹10.1 L+₹86,669.84 (9.39%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹10.1 L+₹87,037.24 (9.43%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹10.3 L+₹1.0 L (11.4%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹10.4 L+₹1.2 L (12.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
12 Sept 2024, 6:00 pmClosed
AGE (I) SURYALANKA
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA POST -522 102 SURYALANKA
AS PER BOQ AND TENDER DOCUMENT
2024_MES_669375_1
AGE(I)/SL/8621
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
AGE (I) SURYALANKA
AS PER BOQ AND TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) SURYALANKA
₹19,200
Yes
20 Sept 2024
31 Aug 2024
14 Sept 2024
31 Aug 2024
12 Sept 2024
7 Sept 2024
2 Sept 2024 - 3 Sept 2024
Amount
Supply, installation, testing and commisioning of electric driven domestic monoblock centrifugul pump of capacity 1 HP, 230V, single phase, 50 Hz, suction and delivery size 25mm, Flow rate 2800-700 LPM, Cast Iron Boddy, not less than 25m head inclusive of casing and impeller madeout of bronze and stainless steel shaft stuffing box seal gland packed incl vibration pad, suitable bend, elbow, washer, nuts, bolt, studs, thimbles incl all types of cutting / threading / welding/ grouting work and making all connection to the delivery and suction pipeline as per site requirement for smooth functioning of water distribution / pumping complete all as specified and as directed. Make - TEXMO DMS03N
Supply, installation, testing and commisioning of Booster Pressure Pump of capacity 0.9 HP with pressure tank of capacity 24 Ltr, electric driven, 230V, single phase, 50 Hz, flow rate upto 4.7 Cubic meter per hour, not less than 20 m head and making all electrical connection and pipe connection to the delivery and suction pipeline as per site requirement complete all as specified and as directed. Make - Grundfos model CM 5-4
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 4 sqmm complete all as specified and directed.
Supplying and fixing MCB Single Pole 6-32 Amps, C Curve, 240V, 10 kA, Complete all as specified and as directed.
Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp Including necessary arrangements for fixing of light on wall/pole/shed by using GI clamps of suitable size making holes, bend for fixing of light ,nut, bolts and washer etc. complete all as specified and as directed.
S&L of ERECTION OF MILD STEEL POLE of medium grade for fixing of the flood lights of size not less than 50 mm dia and height not less than 6 mtrs including excavation of 1mtr depth and 200mm dia for erection pole and PCC foundation 1:3:6 required for erection of pole not less than 0.03 CUM per pole and dummy cap of suitable size on the top of the pole , painting of pole with two coat of synthetic enamel paint over coat of redoxide primer and making good, disposal of excavated earth at a distance exc 50 m n n exc 100 m complete all as specified and as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular size of 4 Sq.mm complete all as specified and as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular size of 6 Sq.mm complete all as specified and as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular size of 10 Sq.mm complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 4.0 core 16 Sqmm
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 4.0 core 25 Sqmm
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cable n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
S&L Sand filling for cable protection above and below cable and rammed down complete all as specified and as directed
S&L Red Bricks common burnt clay building bricks, sub-class ‘B’ designation 75 complete all as specified and as directed.
S&L GI pipe light grade for cable protection with clamps of size not less than 40 mm dia complete all as specified and as directed.
Supply and fixing OFF LOAD change over switch 415V in sheet metal enclosure 4 pole of capacity 63 amps fixed on wall /metalic stand complete all as specified and as directed.
S&F LT junction box outdoor, single door of size minimum 0.8 x 1 x 0.6 m (i.e 0.8 m height, 1 Mtr width and 0.6 mtr depth) or suitble higher size made out of CRCA Sheet of 3.15 mm thick with powder coated painting with four numbers of 100 Amps aluminum bars duly insulated on insulators / suitable size Bakelite sheet fixed including making necessary drilling on bus bars for fixing of out going cables upto 50 Sqmm XLPE - 05 Nos with minimum gap as per IE standards and one No MCCB of capacity 63 A, 4 Pole, 415 V 25 KA and suitable size of angle Iron 50 x 50 x 5 mm thick for stand complete ( free space between MCCB / busbar and other connection items should be provided,) including fixing arrangement by excavaion, PCC etc for the height directed by Engr-in-Charge danger notice sticker, cable glands, internal wiring with FRLS copper wires of suitable size complete all as specified and directed Note : 1. Contractor should submit the diagram of LT panels and Jn box for approval of Engr-in-Charge before placing order. 2. The quoted rate including necessary excavation and PCC work for erection of LT Feeder pillar box, gland, thimbles etc complete
M&L for Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI strip 32X6 by means of bolts, check nut and washers of GI or steel, GI pipe light grade of 40 mm bore as protection pipe, GI strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia medium grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
S&F LED Bldg. Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
K VENUGOPALA SWAMY (BID ID -3092710)
BEEGEE DESIGN SYSTEMS (BID ID -3094487)
M/S SIRI BUILDERS (BID ID -3093402)
DHANA CONSTRUCTIONS (BID ID -3093427)
SHIKHARA PROJECTS (BID ID -3093837)
PAVANI INFRAS (BID ID -3093627)
HARSHA CONSTRUCTIONS AND ENGINEERING WORKS (BID ID -3093082)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .