Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.4 LAccepted-AOC UNIT NO 1005 10TH FLOOR JMD MEGAPOLIS SOHANA ROAD SEC 48 GURGAON 122018 | GURUGRAM | HARYANA | 122018 | ₹81.4 L Quoted ₹82.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹92.0 L+₹9.8 L (11.9%)Rejected-Finance | ₹92.0 L+₹9.8 L (11.9%) | L2 | Rejected-Finance Reject |
| 3 | Not Admitted-Fee/PreQual/Technical 00 BALOD CHIKHLAKASA WARD NO 03 DALLI ROAD DURG CHHATTISGARH 491228 | BALOD | CHHATTISGARH | 491228 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | ParknSecure India Pvt ltd L1 | Areteinfo Technologies Private Limited L2 |
|---|---|---|---|---|---|
| 1.00 | Ultrasonic/Infrared sensors Supply Installation Testing Commissioning of-Ultrasonic Sensor
❑ Detection Range adjustment 2.5 m to 3
❑ Installation location - Above and middile of parking slot
❑ Horizontal – 1. 0~0.5m, Vertical- 2~3m ❑ Operating voltage - DC 10~28V (Rated 24V)
❑ Power consumption - <1W
❑ Working temperature -10°C ~ +55°C , humidity-up to 70%RH
❑ Appearancematerial- ABS engineering plastics
❑ Communicationmode - RS485
❑ Communicationmode - 2 RJ45 ports
❑ Communication distance - ≤300m
❑ Power supply distance - ≤150m
❑ Response time of the detector-After parking - 2s~10s
❑ Ranging error- 2cm
❑ Detection accuracy - >99.9%
❑ Communication frequency: 9600 | 300 | Nos. | 5,841 ₹17,52,300 Lowest | 7,670 ₹23,01,000 |
| 2.00 | LED indicators (green/red) Supply Installation Testing Commissioning of- LED lamp indicators . Each parking space requires one LED installed in front of the parking space. (Red & Green Color)
❑ Installation location - Above front of the parking slot
❑ Power consumption - <1W
❑ Working temperature -10°C ~ +55°C , humidity-up to 70%RH
❑ Appearancematerial- Grey ABS engineering plastics
❑ Communicationmode - RS485
❑ Communicationmode - 2 RJ45 ports
❑ Communication distance - ≤300m
❑ Power supply distance - ≤150m
❑ Type of the indicator light -Red and green two-tone high-light LED
❑ Communication frequency: 9600 | 300 | Nos. | 4,661 ₹13,98,300 Lowest | 5,900 ₹17,70,000 |
| 3.00 | Zone controller Supply Installation Testing Commissioning of- Zone controller - One Zone controller can connect up to 30 ultrasonic sensor LEDs. It gathers and forwards vacancy information from all the detectors to the Central Control Unit, and also forwards commands from the Central Control Unit to the LED information panels connected to it for displaying proper vacant information.
❑ Zone controller to receive data from 30 to 50 Sensor depending upon distance
❑ 32-bit ARM processor
❑ Remotely upgraded to always satisfy the user's requirements.
❑ CAN BUS communication interface
❑ Two-way RS485 communication interface
❑ Industrial design for strict tests of static, lightning stroke,surge and group pulse
❑ Devices is designed with the short circuit transposition and misconnection protection
❑ Working temperature -10°C~ +55°C
❑ Communicationmode 1-circuit CAN / 2-circuitRS485
❑ Casingmaterial-Mild Steel Powder Coated Black
❑ Communication distance CAN: ≤1000m (RVSP 2*1.0, RS485: ≤300m
❑ Single-circuit node capacity 15-25 Sensors and LED
❑ Power consumption ≤2W | 10 | Nos. | 44,673 ₹4,46,730 Lowest | 47,200 ₹4,72,000 |
| 4.00 | Floor Controller Supply Installation Testing Commissioning of- Floor Control Unit - One parking floor requires one Floor Control Unit. . The Floor Control Unit gathers and forwards information from Zone Controllers to the Central parking guidance server for management operation. It can also provide vacancy information to additional level or area vacancy LED display boards connected. Controllers should use RS485/TCP/IP, Can BUS hybrid communicationmechanismto solve the Problem of long-distance communication, the expansion of network nodes, group managementissues.
❑ The Node/Floor Controller to collect all parking information in floor and uploading the related collected information code to the Central Controller. I It is used to connect Zone and
Central Controllers. BUS communicationmechanism
❑ 32-bit ARM processor
❑ Floor Controller can be remotely upgraded
❑ overvoltage protection
❑ Groupingmanagement of the Zone Controller
❑ Optimal management of network communication and complete protocol conversion and data grouping
processing between centralized and Zone Controllers.
❑ Casingmaterial Mild Steel Powder Coated Black
❑ Working temperature -10°C ~ +55°C
❑ Operating voltage AC 110 ~ 240V
❑ Communicationmode 2 CAN-BUS
❑ Communication distance ≤1000m (RVSP 2*1.0)
❑ Power consumption ≤100W | 3 | Nos. | 2,10,630 ₹6,31,890 Lowest | 2,18,300 ₹6,54,900 |
| 5.00 | Central control unit/server Supply Installation Testing Commissioning of- Central Control Unit -One parking facility requires one Central Control Unit. It can connect up to 15 floor Controllers at the maximum. The Central Control Unit gathers and forwards information from Floor Controllers to the PGS parking guidance server for
management operation. It can also provide vacancy information to additional level or area vacancy LED display boards connected. Controllers should use RS485/TCP/IP, Can BUS hybrid communicationmechanismto solve the Problem of long-distance communication, the expansion of network nodes, group managementissues.
❑ Floor Controller can be remotely upgraded
❑ overvoltage protection
❑ Optimal management of network communication andncomplete protocol conversion and data grouping
processing between centralized and Zone Controllers.
❑ Casingmaterial Mild Steel Powder Coated Black
❑ Working temperature -10°C ~ +55°C
❑ Operating voltage AC 110 ~ 240V
❑ Communicationmode 2 CAN-BUS
❑ Communication distance ≤1000m (RVSP 2*1.0)
❑ Power consumption ≤100W | 1 | Nos. | 2,76,710 ₹2,76,710 Lowest | 2,83,200 ₹2,83,200 |
| 6.00 | Digital display boards (entrance + 3 floors) Supply Installation Testing Commissioning of- Main Outdoor display at entry Gate with 7X1 P10 module RGB Main Display (Outdoor at main Gate with Pole mount) Multi Row InformationDisplay
❑ Work Temp: -10° C – 55° C
❑ Multi- Color LED Matrix Display unit
❑ Voltage rating: 230 Vac, 50 Hz
❑ Currentrating: 1A, 5A
❑ Communication frequency: 9600
❑ Luminance: 1000cd/m2
❑ Dot matrix: 320x 120 mm
❑ LED Color: R/G/B Super bright.
❑ Communication: RS232/RS485/TCP/IPOptional
❑ Frequency: 50 – 60 Hz
❑ Cabinet Color : Black
❑ Visibility-40-50 Mtr
❑ Baud: 4800 bps/9600
❑ Customize as persite requirement | 4 | Nos. | 44,816 ₹1,79,264 Lowest | 47,200 ₹1,88,800 |
| 7.00 | Directional signage (per floor) Supply Installation Testing Commissioning of- Directional LED Information Panel - Three digits to show available parking spaces and an arrow for direction.
❑ Brightness 2000 MCD
❑ Communication:RS232/RS485/TCP/IP/PGS
❑ Cabinet Color : Black
❑ Visibility 50 mtr
❑ LED Color: Red /Green Super bright.
❑ Display the empty parking spaces in the form of figure
and arrow,
❑ MS profile and organic glass panel casing
❑ Green indication and distinguishable.
❑ Lamp bead type 6-8 seconds SMD LED lamp bead
❑ Operating AC 110 ~ 240V
❑ Power ≤10W (one direction)
❑ Temperature -10°C ~ +55°C
❑ Humidity ≤90% RH
❑ Luminance 339 LUX | 30 | Nos. | 34,161 ₹10,24,830 Lowest | 35,400 ₹10,62,000 |
| 8.00 | Central control unit/server Supply Installation Testing Commissioning of PGS Server withProcessor- Up to one Intel® Xeon® E 2224G with up to 4 cores per processor
• Memory: IMM Speed Up to 2666 MT/s, Memory Type UDIMM, Memory Module Slots-4 DDR4 slots, Maximum RAM-UDIMM 16GB
• Storage-Front Bays-One 3.5"" 1TB SATA SSD by default; up to 3 x 3.5"" SATA HDDs
• Storage Controllers-Software RAID Intel® VROC 6.x
• Security-Cryptographically signed firmware, Secure Boot, Intel® SGX (Software Guard Extensions), TPM 2.0
• Management: Embedded / At-the-Server, Intel AMT 12.0
• Power Supplies-Bronze 300W
• Ports: Network options:1 x 1GbE
• Front ports:2 x USB 2.0, 1 x USB 3.1, 1 x USB 3.1
• Rear ports: 2 x PS2, 2 x Display ports, 1 x Serial,1 x Audio, 2 x USB 2.0, 4 x USB 3.1
• Slots-PCIe, 1 X Gen3 slot (x16), 2 X Gen3 slot (x4), 1 X PCI
• Form Factor: Mini tower
• Win Server 2019 , 20" Display with keyboard and mouse | 1 | Lump Sum | 3,28,040 ₹3,28,040 | 1,77,000 ₹1,77,000 Lowest |
| 9.00 | UPS system (4-hour backup) | 1 | Lump Sum | 2,21,250 ₹2,21,250 Lowest | 2,36,000 ₹2,36,000 |
| 10.00 | Software development and integration Supply Installation Testing Commissioning of- PGS Software with Software application interface like A program menu allows easy access to all function pages To manage, and monitor the guidance system via a graphic interface of the entire parking facility layout | 500 | Meters | 1,109 ₹5,54,500 Lowest | 1,180 ₹5,90,000 |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
24 Apr 2025, 11:00 amClosed
DMC
Municipal Council, Ambala Sadar
Installation of a sensor-based inventory, space-indicating, and way-guiding system for an existing three-storey multi-level car parking facility with a capacity of 300 cars
2025_HRY_441046_1
EOI/2025/SPL-4
Open Tender
Miscellaneous Services
EOI
365 days
Municipal Council, Ambala Sadar
Please refer Tender documents.
2 documents required · 2 mandatory
₹25,000
Yes
₹2 L
Yes
Municipal Council, Ambala Sadar
9 Dec 2025
18 Apr 2025
24 Apr 2025
18 Apr 2025
24 Apr 2025
18 Apr 2025
22 Apr 2025
Amount
Ultrasonic/Infrared sensors Supply Installation Testing Commissioning of-Ultrasonic Sensor ❑ Detection Range adjustment 2.5 m to 3 ❑ Installation location - Above and middile of parking slot ❑ Horizontal – 1. 0~0.5m, Vertical- 2~3m ❑ Operating voltage - DC 10~28V (Rated 24V) ❑ Power consumption - <1W ❑ Working temperature -10°C ~ +55°C , humidity-up to 70%RH ❑ Appearancematerial- ABS engineering plastics ❑ Communicationmode - RS485 ❑ Communicationmode - 2 RJ45 ports ❑ Communication distance - ≤300m ❑ Power supply distance - ≤150m ❑ Response time of the detector-After parking - 2s~10s ❑ Ranging error- 2cm ❑ Detection accuracy - >99.9% ❑ Communication frequency: 9600
LED indicators (green/red) Supply Installation Testing Commissioning of- LED lamp indicators . Each parking space requires one LED installed in front of the parking space. (Red & Green Color) ❑ Installation location - Above front of the parking slot ❑ Power consumption - <1W ❑ Working temperature -10°C ~ +55°C , humidity-up to 70%RH ❑ Appearancematerial- Grey ABS engineering plastics ❑ Communicationmode - RS485 ❑ Communicationmode - 2 RJ45 ports ❑ Communication distance - ≤300m ❑ Power supply distance - ≤150m ❑ Type of the indicator light -Red and green two-tone high-light LED ❑ Communication frequency: 9600
Zone controller Supply Installation Testing Commissioning of- Zone controller - One Zone controller can connect up to 30 ultrasonic sensor LEDs. It gathers and forwards vacancy information from all the detectors to the Central Control Unit, and also forwards commands from the Central Control Unit to the LED information panels connected to it for displaying proper vacant information. ❑ Zone controller to receive data from 30 to 50 Sensor depending upon distance ❑ 32-bit ARM processor ❑ Remotely upgraded to always satisfy the user's requirements. ❑ CAN BUS communication interface ❑ Two-way RS485 communication interface ❑ Industrial design for strict tests of static, lightning stroke,surge and group pulse ❑ Devices is designed with the short circuit transposition and misconnection protection ❑ Working temperature -10°C~ +55°C ❑ Communicationmode 1-circuit CAN / 2-circuitRS485 ❑ Casingmaterial-Mild Steel Powder Coated Black ❑ Communication distance CAN: ≤1000m (RVSP 2*1.0, RS485: ≤300m ❑ Single-circuit node capacity 15-25 Sensors and LED ❑ Power consumption ≤2W
Floor Controller Supply Installation Testing Commissioning of- Floor Control Unit - One parking floor requires one Floor Control Unit. . The Floor Control Unit gathers and forwards information from Zone Controllers to the Central parking guidance server for management operation. It can also provide vacancy information to additional level or area vacancy LED display boards connected. Controllers should use RS485/TCP/IP, Can BUS hybrid communicationmechanismto solve the Problem of long-distance communication, the expansion of network nodes, group managementissues. ❑ The Node/Floor Controller to collect all parking information in floor and uploading the related collected information code to the Central Controller. I It is used to connect Zone and Central Controllers. BUS communicationmechanism ❑ 32-bit ARM processor ❑ Floor Controller can be remotely upgraded ❑ overvoltage protection ❑ Groupingmanagement of the Zone Controller ❑ Optimal management of network communication and complete protocol conversion and data grouping processing between centralized and Zone Controllers. ❑ Casingmaterial Mild Steel Powder Coated Black ❑ Working temperature -10°C ~ +55°C ❑ Operating voltage AC 110 ~ 240V ❑ Communicationmode 2 CAN-BUS ❑ Communication distance ≤1000m (RVSP 2*1.0) ❑ Power consumption ≤100W
Central control unit/server Supply Installation Testing Commissioning of- Central Control Unit -One parking facility requires one Central Control Unit. It can connect up to 15 floor Controllers at the maximum. The Central Control Unit gathers and forwards information from Floor Controllers to the PGS parking guidance server for management operation. It can also provide vacancy information to additional level or area vacancy LED display boards connected. Controllers should use RS485/TCP/IP, Can BUS hybrid communicationmechanismto solve the Problem of long-distance communication, the expansion of network nodes, group managementissues. ❑ Floor Controller can be remotely upgraded ❑ overvoltage protection ❑ Optimal management of network communication andncomplete protocol conversion and data grouping processing between centralized and Zone Controllers. ❑ Casingmaterial Mild Steel Powder Coated Black ❑ Working temperature -10°C ~ +55°C ❑ Operating voltage AC 110 ~ 240V ❑ Communicationmode 2 CAN-BUS ❑ Communication distance ≤1000m (RVSP 2*1.0) ❑ Power consumption ≤100W
Digital display boards (entrance + 3 floors) Supply Installation Testing Commissioning of- Main Outdoor display at entry Gate with 7X1 P10 module RGB Main Display (Outdoor at main Gate with Pole mount) Multi Row InformationDisplay ❑ Work Temp: -10° C – 55° C ❑ Multi- Color LED Matrix Display unit ❑ Voltage rating: 230 Vac, 50 Hz ❑ Currentrating: 1A, 5A ❑ Communication frequency: 9600 ❑ Luminance: 1000cd/m2 ❑ Dot matrix: 320x 120 mm ❑ LED Color: R/G/B Super bright. ❑ Communication: RS232/RS485/TCP/IPOptional ❑ Frequency: 50 – 60 Hz ❑ Cabinet Color : Black ❑ Visibility-40-50 Mtr ❑ Baud: 4800 bps/9600 ❑ Customize as persite requirement
Directional signage (per floor) Supply Installation Testing Commissioning of- Directional LED Information Panel - Three digits to show available parking spaces and an arrow for direction. ❑ Brightness 2000 MCD ❑ Communication:RS232/RS485/TCP/IP/PGS ❑ Cabinet Color : Black ❑ Visibility 50 mtr ❑ LED Color: Red /Green Super bright. ❑ Display the empty parking spaces in the form of figure and arrow, ❑ MS profile and organic glass panel casing ❑ Green indication and distinguishable. ❑ Lamp bead type 6-8 seconds SMD LED lamp bead ❑ Operating AC 110 ~ 240V ❑ Power ≤10W (one direction) ❑ Temperature -10°C ~ +55°C ❑ Humidity ≤90% RH ❑ Luminance 339 LUX
Central control unit/server Supply Installation Testing Commissioning of PGS Server withProcessor- Up to one Intel® Xeon® E 2224G with up to 4 cores per processor • Memory: IMM Speed Up to 2666 MT/s, Memory Type UDIMM, Memory Module Slots-4 DDR4 slots, Maximum RAM-UDIMM 16GB • Storage-Front Bays-One 3.5"" 1TB SATA SSD by default; up to 3 x 3.5"" SATA HDDs • Storage Controllers-Software RAID Intel® VROC 6.x • Security-Cryptographically signed firmware, Secure Boot, Intel® SGX (Software Guard Extensions), TPM 2.0 • Management: Embedded / At-the-Server, Intel AMT 12.0 • Power Supplies-Bronze 300W • Ports: Network options:1 x 1GbE • Front ports:2 x USB 2.0, 1 x USB 3.1, 1 x USB 3.1 • Rear ports: 2 x PS2, 2 x Display ports, 1 x Serial,1 x Audio, 2 x USB 2.0, 4 x USB 3.1 • Slots-PCIe, 1 X Gen3 slot (x16), 2 X Gen3 slot (x4), 1 X PCI • Form Factor: Mini tower • Win Server 2019 , 20" Display with keyboard and mouse
UPS system (4-hour backup)
Software development and integration Supply Installation Testing Commissioning of- PGS Software with Software application interface like A program menu allows easy access to all function pages To manage, and monitor the guidance system via a graphic interface of the entire parking facility layout
Cabling and networking (per floor)
Installation and commissioning
Training and documentation
Miscellaneous (mounting, fixtures, etc.)
Areteinfo Technologies Private Limited (BID ID -1246394)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .