Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
27 Aug 2024, 6:00 pmClosed
General Manager
Heavy Water Board Facilities, Vadodara
Electrical annual maintenance contract for plant and colony at HWBF-Vadodara
2024_HWB_819806_1
HWBF/V/E-2279/2024-25/AMCELECT
Open Tender
Electrical Works
Item Rate
365 days
Vadodara
As per tender document
2 documents required · 2 mandatory
₹0
₹73,000
HWBF, Vadodara
10 Sept 2024
6 Aug 2024
2 Sept 2024
6 Aug 2024
27 Aug 2024
6 Aug 2024
6 Aug 2024 - 24 Aug 2024
24 Aug 2024
Amount
Part-A of SOQR ( For Plant from sl. No 1 to 75) Fabrication of support for light fitting/tray etc.
Supplying and drawing of 1*1.5 sq mm single core cable in the existing PVC conduit/casing capping.
Supplying and fixing of 19/20 mm...PVC conduit or 25/30 mm casing capping with clamps,...etc.
Supplying and drawing of 1*2.5 sq mm single core cable in the existing PVC conduit/casing capping.
Preparation of earth pit as per IS 3043 and connecting with existing earth pit grid.
Supply & installation of earthing pit frame...size (600 x 600)mm, including masonary…..labour.
Supply,Installation and connection.. of 8 SWG GI wire for carrying out earthing of LPBS, motors.
Supply , Installation and connection….of 12 SWG GI wire for carrying out earthing of LPBS, motors.
Supply and laying ...GI strip 25x3 mm size.
Supply and laying of ...GI strip 50 X 6mm size.
Preparation for Laying of cables Underground Road cutting and making good the same by using Plain concrete cement including supply of materials i.e. aggrregate, ..filling and labour required.
Motors having power rating 11 KW
Motors having power rating 13 KW
Motors having power rating 15 KW
Motors having power rating 18.5 KW
Laying of 1.1KV grade, PVC-A-PVC, FRLS cables on Tray/Trench/ Structure. Cables upto 25 mm OD
Cables of 26 mm to 40 mm OD
Cables of 41 mm to 55 mm OD
Cables of 56 mm to 75 mm OD
Removal of 1.1KV grade PVC/A-PVC/FRLS Cables from Tray/Trench/ Structure. Cables upto 25 mm OD
Cables upto 26 mm to 40 mm OD
Cables upto 41 mm to 55 mm OD
Cables upto 56 mm to 75 mm OD
Glanding & termination (Flameproof) of 1.1KV PVC-A-PVC, FRLS Copper (Cu) Cables.(Supply of glands and lugs shall be in the scope of contractors.) Glanding & terminations of 3C/4C X 2.5 sq.mm
Glanding & terminations of 7C/12C X 2.5 sq.mm
Glanding & terminations of 3C/ 4C X 4.0 sq.mm
Glanding & terminations of 3C/ 4C X 6.0 sq.mm
Glanding & termination (Flameproof) of 1.1KV PVC-A-PVC, FRLS Aluminium (AL) Cables. (Supply of glands and lugs shall be in the scope of contractors.) Glanding & terminations of 3C/ 4C X 6.0 sq.mm
Glanding & terminations of 3C/ 4C X 10/16 sq.mm
Glanding & terminations of 3C/3.5C/ 4C X 25 /35 sq.mm
Glanding & terminations of 3C/3.5C X 50/70 sq.mm
Glanding & terminations of 3C/3.5C X 95/120 sq.mm
Glanding & terminations of 3C/3.5C X 150/185 sq.mm
Glanding & termination (Non-Flameproof) of 1.1KV PVC-A-PVC, FRLS Copper (Cu) Cables. (Supply of glands and lugs shall be in the scope of contractors.) Glanding & terminations of 3C/4C X 2.5 sq.mm
Glanding & terminations of 7C/12C X 2.5 sq.mm
Glanding & terminations of 3C/ 4C X 4.0 sq.mm
Glanding & terminations of 3C/ 4C X 6.0 sq.mm
Glanding & termination(Non-Flameproof)of 1.1KV PVC-A-PVC, FRLS Alu-minium Cables. (Supply of glands and lugs shall be in the scope of contractors.) Glanding & terminations of 3C/ 4C X 6.0/10 sq.mm
Glanding & terminations of 3C/ 4C X 16 sq.mm
Glanding & terminations of 3C/ 4C X 25 sq.mm
Glanding & terminations of 3C/3.5C X 35 sq.mm
Glanding & terminations of 3C/3.5C X 50 sq.mm
Glanding & terminations of 3C/3.5C X 70 sq.mm
Glanding & terminations of 3C/3.5C X 95 sq.mm
Glanding & terminations of 3C/3.5C X 120 sq.mm
Glanding & terminations of 3C/3.5C X 150 sq.mm
Glanding & terminations of 3C/3.5C X 185/240 sq.mm
Single core (Un-Armoured) Copper (Cu) 1.1KV PVC-A-PVC, FRLS Cables. (Supply of lugs shall be in the scope of contractors.) Lugging & terminations of 4.0/6.0 sq.mm
Lugging & terminations of 50/70/95 sq.mm
Lugging & terminations of 120/150 sq.mm
Lugging & terminations of 300/400 sq.mm
Supply of 3M/M-seal make cable jointing kit and carry out jointing of 1.1KV PVC-A-PVC, FRLS Cables copper (Cu) of size. 3C/4C/7C X 2.5 sq.mm
12C/16C X 2.5 sq.mm
3C/4C X 4.0sq.mm
3C/4C X 6.0sq.mm
Supply & installation of 3M/M-seal make cable jointing kit and carry out jointing of 1.1KV PVC-A-PVC, FRLS Cables Aluminium (Al) of size: 3C/4C X 6.0/10.0 sq.mm
3C/4C X 16/25 sq.mm
3C/ 3.5C X 35/50 sq.mm
3C/3.5C X 70 / 3C X 95 sq.mm
3.5C X 95 / 3C X120 sq.mm.
3.5C X 120 / 3C X 150 sq.mm
3.5C X 150 / 3C X 185 sq.mm
Installation of cable trays of size 500mm wide on supports.
Installation of cable trays of size 250/150 mm wide on supports / structures.
Supply, installation and testing of Vertical Air terminations for lightning protection as IS-2309.
Repairing, rewinding of ceiling fan motor includes bearings & capacitor 45-60 watt
Repairing, rewinding of exhaust fan ( 300 mm) motor includes bearings & capacitor 50-60 watt
Repairing, rewinding of exhaust fan/pedestal fan/air cooler (400/500 mm sweep) motor includes bearings & capacitor (60-80) watt
Making arrangement for attending trouble shooting of elect. system like repairing of light fitting, board / fans / tube lights…etc. beyond 8hrs (single visit of 2 hrs)
Making arrangement for assisting and cleaning & trouble shooting of elect. system like panels, motors, light fitting... etc. beyond 8hrs ( single visit of 2 hrs).
Earth reisistance measur. and maintenance of Earthing Pit.
Making arrangement for supervision of job ….maintenance of electrical system………. during General shift / Round the clock shift duty for 8hrs.
Making arrangement for attending trouble shooting of electrical system……..General shift / Round the clock shift duty for 8hrs.
Making arrangement for assisting and logging the data….f electrical system like …..general shift / Round the clock shift duty for 8hrs.
Making arrangement for assisting and cleaning of electrical system……... during General shift / Round the clock shift duty for 8hrs.
Part-B of SOQR (for colony maintenance from sl. No 76 to 79) Making arrangement for attending trouble shooting of electrical system…….General shift / Round the clock shift duty for 8hrs in colonies
Making arrangement for assisting and cleaning of light fitting….etc. for 8 hrs in Nizmpura & Danteshwar olonies.
Making arrangement for attending trouble shooting of elect. system …..fans / tube lights…etc. beyond 8hrs (single visit of 2 hrs) at colonies.
Making arrangement for assisting and cleaning & trouble shooting of elect. System... light fitting... etc. beyond 8hrs ( single visit of 2 hrs) at colonies.
shiva solutions
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .