Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹41.4 L+₹4.8 L (13.2%)Rejected-Finance 164 HIRANI NAGAR OPP SIDDHI VINAYAK TEMPLE MADHAPAR KUTCH 370 020 | KACHCHH | GUJARAT | 370020 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹43.3 L+₹6.7 L (18.4%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
18 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT-370001
REPAIRS MAINT AND REPLACEMENT OF LT UG CABLES, LT OVERHEAD LINES, AND CONNECTED ITEMS IN DOMESTIC AREA AT AF STN BHUJ
2024_MES_643469_1
8727/V/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) BHUJ
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) BHUJ
₹84,000
Yes
30 Mar 2024
21 Feb 2024
20 Mar 2024
21 Feb 2024
18 Mar 2024
6 Mar 2024
23 Feb 2024 - 24 Feb 2024
Amount
Dismantling ACSR or ACC conductor complete all as specified and directed by Engineer-in-Charge.
Dismantling LT/HT insulators any type, any size complete all as specified and directed by Engineer-in-Charge.
Dismantling cradles fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed by Engineer-in-Charge
Dismantling cross-arms of M.S. channel or angle sections etc complete all as specified and directed by Engineer-in-Charge.
Dismantling stay assembly complete all as specified and directed by Engineer-in-Charge.. (demolition of concrete, etc. and excavation measured separately)
Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level . complete all as specified and directed by Engineer-in-Charge.
Returning and filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Eng-in-Charge.
Material & labour for sand cushioning for UG cables using dry river sand; gently punning down complete all as specified and directed by Engineer-in-Charge. ( Note : For measurement purpose punned thickness shall be considered)
Supplying & laying un-reinforced precast concrete cable cover class LV, type - II, flat, size 300x 180 x 40 mm laid transverse to cable complete all as specified and directed by Engr-in-Charge.
Supply & fix connecting ,testing and commissioning and jointing,LT under ground cable, 1100 volts grade, XLPE insulated armoured with galvanised round steel wire or steel strip,electric power cables heavy duty,with multi stranded aluminium conductor,laid in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads/path/drain/culverts or encased in GI pipe fixed & testing and commissioning complete all as specified and directed by Engineer-in-Charge for following sizes:- Note:- (i) Sand cushioning, Cable protection cover, GI pipes, excavation and earth work shall be measured and paid for separately under respective items of BOQ.
LT cable 6 Sqmm , 2 core
LT cable 10 Sqmm , 4 core
LT cable 16 Sqmm , 4 core
LT cable 25 Sqmm , 4 core
LT cable 50 Sqmm , 3.5 core
LT cable 70 Sqmm , 3.5 core
LT cable 95 Sqmm , 3.5 core
Material & labour for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing complete all as specified and directed by Engineer-in-Charge for following sizes:-
Cable size 70 to 120 Sqmm, 3.5 core
Cable size upto 50 Sqmm, 3.5 core
Material & labour for heat shrinkable indoor/ outdoor LT end terminations for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing complete all as specified and directed by Engineer-in-Charge for following sizes:-
Cable size 240 to 300 Sqmm 4 core
Cable size upto 70 to 120 Sqmm, 4.0 core
Cable size upto 25 to 50 Sqmm, 4.0 core
Cable size upto 6 to 16 Sqmm, 4.0 core
Supply & fix GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS FI clamps with necessary bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge for following sizes:-
50mm bore
80mm bore
100mm bore
Supply & fix in replacement MCCB's,415 Volts , fix / adjustable type having complete all as specified and directed by Engineer-in-Charge for following capacities:-
MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA
MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA
MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
Material & labour for earthing complete with GI earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of GI protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete all as specified and directed by Engineer-in-Charge. Note: GI strip exceeding 7.5m long shall be measured & paid seperately.
Material & labour for complete cleaning of the internal & external parts of LT panel; checking & testing of all the components of the panel for cable insulation, lugs, connections and the like; replacement of & including provision of minor parts like lugs, insulation tape, nuts bolts, connectors and the like as directed by Engineer-in-Charge; replacement and / or welding of existing damaged hinges of the panel; preparation of old painted surfaces (internal & external) of the panel, complete removal of existing paint using emry paper grade 220, by sanding and scrubbing, application of corrosion resistant primer by sprayers, applying hammer finish metal paint using sprayers in two coats and till shining surfaces are obtained; application of two coats of epoxy black paint on panel frames; complete all as directed by Engineer-in-Charge.(Approximate average size of panel=1.50x0.75x0.45m) (Note - Rates included for provision of sufficient technicians for getting electric shut down and to attend the shutdown on site till completion. Replacement of major items like MCCBs etc. shall be measured & Paid for separately).
Material & labour for Zebra painting white & sky blue strips 30 cm height in alternate colour strip upto 1.5 meter from top edge of coping of electric poles with synthetic enameled paint two coats and numbering to poles with 80mm size letter with black synthetic enameled paint complete all as specified and directed by Engineer-in-Charge.
Supply & fix PC-GFC polycarbonate juction box of size outside dimensions 205x 225x 112 mm with terminals IP-65/66 protection, 01 Nos MCB SPN C series of capacity 06 Amps as approved by the Engineer-in-Charge including connector and fixing on pole with and including MS clamps made out of 25 x 3mm MS flat iron, nut, bolts etc complete all as specified and directed by Engineer-in-Charge. Note :-The cost of junction box installation includes making hole of suitable size for entry and exit of cable upto 35x3.5 core size, making new lugs of cables of entry and exit.
Supply & fix PC-GFC polycarbonate juction box of size outside dimensions 300x 450x 170 mm with terminals IP-65/66 protection, as approved by the Engineer-in-Charge including connector and fixing on pole with and including MS clamps made out of 25 x 3mm MS flat iron, nut, bolts etc complete all as specified and directed by Engineer-in-Charge. Note :-The cost of junction box installation includes making hole of suitable size for entry and exit of cable upto 95 Sqmm 3.5 core size, making new lugs of cables of entry and exit.
Supply & fix in replacement of pin type, (LT) porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement shackle type procelain, vitreous white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of 75mm height, 90mm max dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
Supply & fix spacer made out of hard/rigid PVC as approved by Engr-in-Charge on the LT OH line suitable for 4 wire system LT OH ACSR conductor complete all as specified and directed by Engineer-in-Charge.
Material & labour for finding out LT fault in feeder of affected area with deploying trained electrician and helper seggregate/ isolate the feeder carry out maintenance work such as repair of jumper,insulators ,conneted items and then after charge the feeder with load in presence complete all as specified and directed by Engineer-in-Charge.
Material & labour for erection of precast LT cable route / cable path indicator,made out of PCC 1:2:4 ,type BO,12.5 mm using graded stone aggregates of size 100 Cm (Height) x 12 Cm (Width) x 8 Cm (Thichness), painted with orange colour lettering synthetic paint and letters 4 inch "LT CABLE" to be written with black colour lettering synthetic paint and embedded in PCC block 1:3:6 type C2 (using 40mm graded stone aggregate) of size 15cm x 15cm x 20cm including necessary excavation for PCC block, placed at interval of every 30 M complete all as specified and directed by Engineer-in-Charge.
Material & labour for maintenance of ACB 440 Volts,1000/630 Amps including removal of ACB trolley, cleaning of all copper male and female contact, tightening of all connections, checking of all auxiliary contacts, control wiring, etc. refixing the ACB trolley to its original position including proper setting of manual/motorize operation of ACB, checking/setting of tripping system, etc complete all as specified and as directed by Engr-in-Charge. Note:- (i) Maintenance to be carried out by the reps of companies OEM of companies like C & S, L&T or equivalent (ii) After completion test certificate shall be furnished from OEM
Supply & fix in replacement of ACB spring charging motor 250 Volts AC/DC (as per site requirment) suitable for AH 10 D 1000/630 Amps with gear assembly complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of CT of suitable ratio for ACBs 1000/ 630 Amps capacity complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of relay suitable for ACBs of 1000/ 630 Amps capacity 440 volts complete all as specified and directed by Engineer-in-Charge
Supply & fix TNC switch for operation of ACB as per sample complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement of closing coil, ISI marked suitable for 440 V ACB panel complete all as specified and directed by Engineer-in-Charge
Supply & fix in replacement of tripping coil, ISI marked suitable for 440 V ACB panel complete all as specified and directed by Engineer-in-Charge
Supply & fix digital/analog Amp meter with CT suitable for LT panel 0-440 Volts complete all as specified and directed by Engineer-in-Charge.
Supply & fix digital/volt meter suitable for LT panel 0-440 Volts complete all as specified and directed by Engineer-in-Charge.
Supply & fix LED lamps for LT panel red, yellow & green complete all as specified and directed by Engineer-in-Charge
Supply & fix shrinkable PVC insulation sleeves of suitable size for cables upto 50 sqmm 1100 volts in colour red, yellow, blue and black of 1m length complete all as specified and directed by Engineer-in-Charge.
Supply & fix LED flood light 100 Watt, IP66 electronic LED driver with IK 07 exclusive die-cast aluminium body with toughened glass visor, open circuit protection, over voltage protection, surge voltage protection upto 10 kv with built in SPD, lumen LED>140 lm/Watt viewing angle 120 degree suitable for highlightening architectural fixed with suitable GI clamps having two coat of enamal paint, nut bolts complete all as specified and directed by Engineer-in-Charge. Note : Contractor will arrange T&P and veh required for repairing lights and the cost for the same will be incl in the quoted rate.
Supply & fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. Note : Contractor will arrange T&P and veh required for repairing lights and the cost for the same will be incl in the quoted rate.
Supply & laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4.0 sq. mm 2.0 core nominal cross section in service connections complete all as specified and directed by Engineer-in-Charge.
Stretching of exixting aluminium conductor steel reinforced (ACSR) of any mounting on over head line, properly on insulator with required span and sag including binding with aluminium conductor of 2 mm dia as binding wire complete all as specified and directed by Engineer-in-Charge (Span-5 conductors of 40 m length each) .
Material & labour for boring under roads / pavement / hard standing without disturbing the top surface by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and directed by Engineer-in-Charge. Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost.
Cutting and trimming and vending the tree branches along HT over head lines after arranging electrical shout down, including taking all precautions while working on lines using own T&P by the contractor complete all as specified and directed by Engineer-in-Charge. Note:- (i) Branches of trees shall be cut upto 3 m from the outer conductor of OH line. (ii) Cutting/trimming of branches shall be done after obtaining necessary shut down in writing bt the Engineer-in-Charge to avoid any casualty
Material & labour for cleaning the sub station (the entire sub station to be kept clean by brooming unwanted materials, pulling the unwanted vegetation inside the sub station, bottom of poles, stay assy, cleaning of VCB/ACB/LT cables on site complete all as specified and directed by Engineer-in-Charge. Job shall include thorough cleaning of 40 sub station. Cleaning shall be done once in a quarter for all 40 sub stations. Note:- Contractor's surpervisor with sufficient labours and an electrician alongwith tools and plants will report to JE in the morning for taking over site of cleaning as ans when direcred by Engineer-in-Charge. The cleaning shall be done upto the satisfaction of Engineer-in-Charge.
Pelectricals
Abhishek Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .