Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-Finance | L1 | Accepted-Finance YES | |
| 2 | L2₹9.1 L+₹1.1 L (14.3%)Accepted-Finance B 1311 GROUND FLOOR GD COLONY MAYUR VIHAR PHASE 3 DELHI 110 096 | EAST DELHI | DELHI | 110096 | L2 | Accepted-Finance YES | |
| 3 | L3₹9.9 L+₹2.0 L (24.8%)Accepted-Finance E 107 LOWER GROUND FLOOR GREATER KAILASH II NEW DELHI SOUTH DELHI DELHI 110048 | SOUTH DELHI | DELHI | 110048 | L3 | Accepted-Finance YES |
Tender Value
₹15.8 L
EMD Value
₹31,500
Closing Date
8 Jul 2020, 11:00 amClosed
P K Gupta Addl CCE
Chief Construction Engineer (RandD) Central Rao Tula Ram Marg Behind Army HQ Camp Delhi Cantt 110 010
CONSULTANCY SERVICE FOR PROVISION OF CALIBRATION LAB BUILDING AND AREA DEVELOPMENT IN 32 BIGHA LAND AT SASE MANALI PROJECT ANSHANKAN
2020_DRDO_563609_1
CCE(RandD)C/9245/CONS/SASE
Limited
Consultancy
Item Rate
540 days
MANALI
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
Chief Construction Engineer (RandD) Central
₹31,500
Yes
16 Jul 2020
8 Jun 2020
9 Jul 2020
9 Jun 2020
8 Jul 2020
10 Jun 2020
Amount
Part : - I Consultancy services
Buildings including Internal Service
Calibration Lab Building
Central Heating System
EXTERNAL SERVICES External Electrification,External Lighting ,Fire Fighting System, Water Supply
Miscellaneous Work Roads, Hard standing, Drains, Fire Alarm System, Earthing, Lightning Protection
Part : - II Topographical survey
Mobilisation / Demobilisation of Survey equipment with its accessories and survey staff etc. from office to the site for carrying out the survey work at site.
Carrying out topographical survey of the area with total station, giving traverse of surveyed area, spot levels at about 10m and marking of existing major structures & roads, showing contours at 1.0m interval complete.
Providing and fixing PCC 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 230 x 230 x 750mm temporary bench mark pillars,boundary pillars, gate pillars and at sharp turning points of boundaries, where ever required, including excavation, cost and conveyance of materials and painting with identification marks numbering & levels engraved etc. all complete as per direction of Engineer-in-charge.
Providing & fixing RCC 300x300x100 mm 1:2:4 (1 cement :2 coarse sand: 4 graded stone aggregate 20 mm nominal size) permanent bench mark pillars including excavation, cost and conveyance of materials and painting with identification marks numbering & levels engraved etc. all complete as per direction of Engineer-in-charge.
Submission of 3 sets of Survey report / drawings including one set CD with the following :-. (a) Traverse & spot levels (b) Contour maps (c) Location Maps
Part : - III Soil-Investigation
Mobilization of tools of machine Equipment from laboratory to site and back including shifting from one bore hole to another as directed by Engineer-in-charge.
Making 100 mm dia or NX size dia bore in any soil strata up to 10m depth or refusal whichever is met earlier and collecting / conducting SPT / UDS / DS at the depths of 1m, 2m, 3m, 4.5m, 6m, 7.5m, 9.0m, 10m.
(a) All types of Soil
(b) Soft distegrated Rock
Carrying out various laboratory tests of UDS/SPT/DS samples as per relavent BIS at alternate depths (Which ever applicable) :- (i) Sieve analysis (ii) Atterberg's limit (iii) Field moisture content (iv) Bulk density (v) Specific gravity (vi) Shear test for cohesion & angle of shearing resistance. (vii) DFS Test (viii) SPT 6 (ix) Field permeability test 6
Determining various soil strata by using 4 point for earthing -soil resistivity testing by wenners method (IS:3043 1987) AT 8 M C/C and submission of report.
Conducting field moisture content & field density and collecting disturbed samples at site for CBR test Carrying out various laboratory tests of samples :- (i) Sieve analysis (ii) Atterberg's limit (iii) DFS Test (iv) CBR value
Submission of sub-soil report in triplicate giving site plan showing test points, sub soil profile, results of field investigations, laboratory test results calculation of SBC from SPT test, Comprehensive recommendations regarding type of foundation to be provided for the proposed structure.
satish kumar mathur and associates
ATKV CONSULTANTS PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .