| Sl No | Description | Qty | Unit | Abhishek Enterprises L3 | M/S S. SINGH TRADERS L1 | ANAND ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster of any description from brick wall or concrete surfaces including racking out joints and hacking for key, scrubbing down with water etc complete all as directed. | 106.5 | Sqm | 80 ₹8,520 | 50 ₹5,325 | 20 ₹2,130 Lowest |
| 2.00 | M & L for 15 mm thick of plaster in CM (1:6) on brick work / RCC concrete surfaces of wall and finish the surface even and smooth without using extra cement complete all as specified and directed. | 34.8 | Sqm | 320 ₹11,136 | 300 ₹10,440 Lowest | 350 ₹12,180 |
| 3.00 | M&L for preparation and applying two coats of cement base paint over new plastered surface of wall over new surfaces complete all as specified and directed. | 34.8 | Sqm | 190 ₹6,612 | 50 ₹1,740 Lowest | 160 ₹5,568 |
| 4.00 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified & as directed. | 17 | 10 Sqm | 1,500 ₹25,500 | 500 ₹8,500 | 270 ₹4,590 Lowest |
| 5.00 | M & L for 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes like tiles etc complete all as specified and directed. | 348.2 | Sqm | 320 ₹1,11,424 | 250 ₹87,050 Lowest | 275 ₹95,755 |
| 6.00 | M & L for coloured joint free non skid tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. | 170 | Sqm | 1,550 ₹2,63,500 | 1,250 ₹2,12,500 | 1,000 ₹1,70,000 Lowest |
| 7.00 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.,) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. | 266 | Sqm | 30 ₹7,980 | 50 ₹13,300 | 20 ₹5,320 Lowest |
| 8.00 | M & L for Anodised aluminium snap grid having Size of grid 605 x 605mm frame work for false ceiling all as specified complete all as specified and directed. | 136 | Sqm | 825 ₹1,12,200 | 300 ₹40,800 Lowest | 800 ₹1,08,800 |
| 9.00 | S & F of 9mm thick PVC laminated gypsum ceiling tiles size of 600mm x 600mm, square edge, front side laminated PVC and back side aluminium foil complete all as specified and directed. (Frame work for ceiling shall be measured and paid separately). | 136 | Sqm | 900 ₹1,22,400 | 700 ₹95,200 Lowest | 800 ₹1,08,800 |
| 10.00 | Dismantling asbestos cement (corrugated or semi corrugated, etc) sheets in roof covering complete all as specified. | 171 | Sqm | 100 ₹17,100 | 50 ₹8,550 Lowest | 50 ₹8,550 Lowest |
Tender Value
₹42.9 L
EMD Value
₹85,740
Closing Date
8 Dec 2025, 6:00 pmClosed
GE ARMY
BHUJ
SPL REPAIR TO BLDG NO T/OPS-153 TS/QM OFFICE, SPL REPAIR OF LT UG CABLE, LT PANEL, SWITCH GEARS AND SPL REPAIR TO BLDG NO T/PFS-95 AT MIL STN GANDHIDHAM UNDER GE ARMY BHUJ
2025_MES_740095_1
8358
Open Tender
Civil Works
Item Rate
180 days
BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ARMY
₹85,740
25 Feb 2026
17 Nov 2025
10 Dec 2025
17 Nov 2025
8 Dec 2025
1 Dec 2025
Taking down cement plaster of any description from brick wall or concrete surfaces including racking out joints and hacking for key, scrubbing down with water etc complete all as directed.
M & L for 15 mm thick of plaster in CM (1:6) on brick work / RCC concrete surfaces of wall and finish the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation and applying two coats of cement base paint over new plastered surface of wall over new surfaces complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons,dados etc laid, bedded and pointed in any mortar and removal of rubbish off the site complete all as specified & as directed.
M & L for 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes like tiles etc complete all as specified and directed.
M & L for coloured joint free non skid tiles 7 to 8 mm thick (Square / Rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.,) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M & L for Anodised aluminium snap grid having Size of grid 605 x 605mm frame work for false ceiling all as specified complete all as specified and directed.
S & F of 9mm thick PVC laminated gypsum ceiling tiles size of 600mm x 600mm, square edge, front side laminated PVC and back side aluminium foil complete all as specified and directed. (Frame work for ceiling shall be measured and paid separately).
Dismantling asbestos cement (corrugated or semi corrugated, etc) sheets in roof covering complete all as specified.
Supply & fix of Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified as directed by manufacturer on steel members including scaffoldings of any height complete all as specified and directed.
Supply & fix of Pre- painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified as directed by manufacturer on steel members including scaffoldings of any height complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome complete all as specified and directed.
Taking down of chowkhats / frames n exc 1.50 sqm each with taking down shutter each complete all as specified and directed.
S & F powder coated anodised Aluminium alloy sections sliding windows with frames Series-B (18 mm) and , 3 track/2 trck sliding shutters duly fitted with neoprene beading, glazing clips, two shutters tinted glass panes 4.80 mm nominal thickness one shutter with stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles 50 micron coloured powder coated aluminium decorative grill design No DG-117,10 mm etc. complete all as specified and directed. Note :Rates include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle with or without opeing for AC as directed by EIC etc
Taking down of chowkhats / frames exc 1.50 Sqm but n exc 4.0 sqm each without taking off shutter each complete all as specified and directed.
S & F for Powder Coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing Powder Coated anodised door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips, ruber neoprene packing, handles 2 NOs in each door, hinges, anodised aluminum snap beading screws 5.50 mm thick sheet glass as in paneIs 12 mm particle board for insulation purposes, fixed with nails to timber/ aluminum frame work including at site as per specification & drawing complete all as specified and directed.
S & F for Door closer hydraulically regulated, designation No 1 universal type, suitable for door shutters upto 700mm in width and of weight not more than 35kg and fixing complete all as specified.
S & F mortice lock, vertical type size 100mm complete all as specified.
S & F of 30 mm thick flush pannel for partitions solid core construction,with block board core and plywood face panel, commercial type on both sides , fixed with nails to timber/ aluminum frame work, one or more rebates including joining cleat for fixing etc. complete all as specified.
M & L for preparation of new wooden surfaces of any description, not otherwise described,over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including scafoldings of any hieght complete all as specified and directed.
S & F in repairs to Harrison rails, (curtains rods) anodised aluminium alloy, powder coated with fixing brackets, stops, rollers etc complete all as specified and directed.
Demolition of precast concrete block walling and similar items i.e. ashlar facing dressing stone work, precast concrete articles etc of any description and in any position built in cement mortar including all quoins, arches and pillars etc and disposing off rubbish) off the premises of cantonment
M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in Modular bricks in cement mortar 1:6 including curing,racking of joints etc. complete all as specified & as directed.
Demolition of cement concrete of any description and in any position (unreinforced) in ground floors/ paving/plinth not exceeding 15 cm thick (below or above GL)
M & L for cement concrete type C-2, 1:3:6 (40mm graded aggregate), 75mm thick. as in plinth protection finished even and smooth without using extra cement including expansion joints
M & L for powder coated aluminium snap grid having a size of 605mm x 605mm and sections incorporated in frame work shall conform to IS 733, IS 737 and IS 1285 and snap grid frame work shall be fixed to ceiling with supporting hanger 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all as per manufacturer's instruction. The main & cross tees shall be jointed at junction/crossings with anodized aluminum angle bracket of size 19.05mm x 19.05mm x 1.45mm, weighing 0.14 Kg per RM, fixed with suitable mild steel, bolts nuts and washer all as per manufacturer's instruction, the snap grid shall be supported at ends all along the wall with anodized aluminum angle of size 38mm x 25mm x 2.18mm, weighing 0.358 Kg per running meter complete all as specified and directed.
S & F of 9mm thick PVC laminated gypsum ceiling tiles size of 600mm x 600mm, square edge, front side laminated PVC and back side aluminium foil complete all as specified and directed. (Frame work for ceiling shall be measured and paid separately).
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the primises complete all as directed.
M & L for Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for coloured non skid digital ceramic joint less tiles 7 to 10 mm thick (square/rectangular) are of each tile exc 0.18 Sqm but n. Exc. 0.38 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement for dado/skirting to match complete all as specified and directed.
M & L for coloured non skid digital ceramic joint less tiles 7 to 10 mm thick (square/rectangular) are of each tile exc 0.18 Sqm but n. Exc. 0.38 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement for dado/skirting to match complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles
M&L rendering 10 mm thick in cement mortar 1:6 on walls, surface finished even & smooth without using extra cement etc.
Taking Down of any type of Door Shutters of any description area exc 2 sq.m each complete all as specified and directed.
S & F of 4mm thick Sheet glass, ordinary quality and glazing sheet glass is ground or obscured or frosted, on one side with oil putty in square n exc 0.5 sq. m in each pane complete all as specified.
S & F of Steel door gauzed shutter including projecting type hinges, steel handle, complete,with glazing bars, dovetailed or welded
S & F of 30 mm thick flush shutter, solid core construction,with block board core and plywood face panel, commercial type on both sides complete all as specified and directed.
S & F of aluminium anodised 200 mm barrel tower bolts of extruded section complete all as specified and directed.
S & F of 150mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F of 100 mm butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type `C'-22 complete all as specified and directed.
S & F of mild steel 300 mm, ordinary rat tail rod pattern springs, including roler and roller plate complete all as specified and directed.
S & F of 300mm long aluminium alloy, anodised sliding door bolt with haps, staple(bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
S & F in repairs of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F in repairs for floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 140 mm, complete all as specified and directed.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for
Excavation in post holes (or similar holes ) each n.exc 0.5 cum, getting out in hard dense soil including returning, filling in and ramming earth or broken rubble mixed with earth aroung, in layers not exceeding 25cm, watering and remooving surplus soil to a distance n.exc 50m and making good surface complete all as specified and directed.
M & L for PCC 1:2:4 type D-2 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
S & F Framed work Fe 290(Gde E-165) as in doors or gates staging of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doo0rs etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete incl painting
M&L preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified.
M&L preparation of old or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified.
Dismantling of water tanks and removing to store having Capacity of Exc 500 litres and n.exc 1000 litres complete all as specified and directed.
S & F for 500 ltrs capacity rotational moulded polyethelene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum wt 210 Gram) complete all as specified and directed .
S & F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000ltr hoisted and fixed in position complete all as specified and directed
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified & directed of following sizes.
(a) 20mm bore outer dia
(b) 25mm bore outer dia
S&F 25mm gate valve, cast copper alloy (ISI Marked) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron / CPVC pipe or for unions and fixed 25 mm bore complete all as specified & directed.
S&F 20mm gate valve, cast copper alloy (ISI Marked) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron / CPVC pipe or for unions and fixed 25 mm bore complete all as specified & directed.
M & L for 15 mm thick plaster in CM (1:6) on brick work / RCC concrete surfaces of wall and finish the surface even and smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed.
M&L for preparation of walls newly plastered surfaces & applying two coatsAcrylic Emulsion paint (weatherproof paint) over one coat of primer
M & L for preparation of old plastered wall surfaces and applying two coats of distemper oil emulsion over a coat of alkali resistant priming paint complete all as specifed and direcetd.
Dismantaling and taking down copper / aluminium point wiring any type / size complete with removing all connection and accessories such as switches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface.
Taking down old and unsrevicable sheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB's , insulator etc complete after removing all connection and making good the disturbed surface all as directed by Engr-in-charge
M&L in rep
air for Point wiring complete with FR PVC insulated unsheathed , 1100 V grade conforming to IS 694 , 1.5 Sqmm (Norminal area) multistranded ,copper conductor cable drawn through in non metallic rigid PVC surface casing caping grade with sutaible size of 1 to 8 module metal flush boxes and back plate for mounting of modular switches/socket and regulators and including modular fornt plate with all acessories complete .
(a) One light point controlled by one way one switch SP 5 Amps ,240 V.
(b) One ceiling/exhaust fan point controlled by one way one switch SP 5 Amps, 240 V
(c) One switch socket outlet 3 Pin, 6 Amps, SP on independent board.
All as per the above item No 65 herein before but with 2.5 Sqmm cable for 3 Pin 5/15 Amps switch socket outlet.
S&F in repair modular switch one way 6 Amps , 1 module type complete .
S&F in repair modular switch 1 way 16A, 1 module of one way complete all as specified and as directed by Engineer-in- Charge.
S&F in repair modular socket , 6 Amps , 2/3 pin combined 2 module type complete.
S&F in repair modular switch socket combination, 6 Amps / 16 Amps , 2/3 pin combined 2 module complete.
S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete
S&F LED ceiling lights fitting 600mmx600mm, 36 watt complete with driver box type with driver, complete all as per directed by Engr-in-charge.
S&F LED light fitting of capacity 9 watt bulk head including driver with three core flexible copper conductor cable of suitable size complete.
Supply and fixing ceiling fans complete with three blades, down rods, regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with squirrel cage induction motor all as specified and directed. (Note : Old ceiling Fan to be deposited in MES store yard for repair)
Supply & Fixing LED street/bldg light fitting luminaire 35 Watt IP-65/66, 230 volts, new generation energy saving & enviormental friendly long life versatile pressure die cast aluminium roadway luminarie with high power LEDs as light source and electronic driver alongwith suitable bracket required as per site for fixing the light complete all as specified & directed
S & F in replacement elegantly industrial general purpose box type luminaire, 1x20 Watt, designed box type LED luminaries, CRCA sheet steel housing with white reflector cover fitted to the body with decorative end covers complete with electronic ballast, spring loaded rotor type lamp holders, connected block with and including 01 No LED lamp 20 Watt and all accessories, pre-wired and connecting the same to ceiling rose with & including twin core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface over and including 2 Nos PVC square box complete all as specified and directed.
M&L for sub main wiring with two runs of 4 Sqmm (2x4 sqmm )1100 volts grade single core FR PVC insulated unsheathed multistranded copper conductorcable confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 2.5 Sqmm (1x2.5sqmm ) single core FR PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. Note:- 2 runs of 4 Sqmm ,one run of 2.5 Sqmm ( 2x4 sqmm + 1x2.5 sqmm ) cable and one meter of conduit will be measured as one unit again.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single epole and neutral ) 08 way, 240 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F MCB SPN, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete.
S&F MCB SP, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete.
M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.
(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.
Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
Supplying , laying , passing through pipe , connecting and testing UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade of size 16 Sqmm 4 core complete.
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation.
Supplying and laying un-reinforced precast concrete cable cover class LV Type 1, flat, size 250mm x 150mm x 40mm complete.
Supply and laying GI tube light grade 40 mm bore complete.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M & L in repair Point wiring for one light/fan point controlled by one modular switch, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC casing & capping with all accessories/ fittings, modular metal flush box, modular white cover plate with frame fitted with screws, washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall/panel surface as existing colour and making good disturbed surfaces of walls, panels, floors, etc. to match with the existing good surfaces of walls, panels,
floors etc. complete all as specified and as directed by Engineer-in- Charge.
All as per Sl item No 90 here-in-before but but for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area.
All as per Sl item No 90 here-in-before but for one socket outlet point 5 amps on independent board controlled by one, one way switch.
S&F in repair Modular switch socket outlet 3 pin 5 Amp' flush type controlled by one switch , complete all as specified and directed by Engineer-in- Charge..
S&F in repair Modular switch socket outlet 3 pin, 15Amp, flush type, complete all as specified and as directed by Engineer-in- Charge.
Ceiling rose, Pilot 3 Plate ceiling rose 6A ,complete all as specified and as directed by Engineer-in- Charge.
S&F in repair Madular Fan step regulator, 120W complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to light fittings complete all as specified and directed
Sub main wiring (casing & capping) with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 2.5 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface in and including taking down old unservicable sub main wiring , complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of PVC conduit & 1 run of 2.5 Sqmm cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Disconnecting and taking out old existing steel/PVC tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union, elbow socket, valves, taps etc, all as directed and specified for 25 mm dia pipe complete all as specified and directed. Note :- Excavation & earth work shall be measured and paid for separately under respective item of Sch 'A'.
Supply and Fixing in any length UPVC pipe 25 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with all fittings,connections, laid in trenches/wall in required length complete all as specified and directed
S & F in repair UPVC Ball valves with operating handle (stop valve) of size 25 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes all as specified and as directed.
Cutting existing steel/ UPVC tubing of any size for alterations, additions or insertions of new GI/CI/ UPVC pipe of size 25mm dia all as specified and directed
Supplying ,Laying , jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 10 Sqmm, 2 core laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid separately.
Taking Down of XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of various size 10 Sqmm, 2 core,16 Sqmm 4 Core and 70 sqmm 3.5 Core laid in trenches/ducts, floors, fixed to walls & DB 's and panels etc complete .
Supplying, Laying, jointing and testing XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade of size 10 Sqmm, 2 core laid in trenches/ducts, floors, fixed to walls etc complete all as specified and directed.
-ditto- here in before Item 106 but of size 4 core 16 Sqmm
M&L for refreshing of incomming and all outgoing XLPE cable at panels /DBs of any size, disconnection of cable , including excavation for taking out cable from loop, refreshing of exsiting all cables by removing damaged insulation portion, providing insulation using best quality insulation tape ,cleaning of panel inside and ouside using vaccum cleaner, including removing old damaged lugs/ thimble with new one as per existing size, MS nuts ,bolts,washer to all incomming and outgoing MCCB as sepcfied and directed by Engineer-in-charge.
M&L for repair of LT panel doors using 75 mm SS hinges, SS latch, including welding work all as specified and directed by Enginner-in-charge.
M&L for spray painting of LT panel inside and outside surface, including surface prepration by scrubbing of existing paint, and applying two coat of synthtic enamel paint over one coat of red oxide, colour of paint & pattern as per exsiting all as specfied and directed by Enginner-in-charge.
Supply and fix in repiars the following items and disconnecting,taking out the old unserviceable one, including necessary replacemnet of lugs ,nuts,bolts, washer of any size and capacity wherever reqd :-
Taking down old and unsrevicable sheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB's , insulator etc complete after removing all connection and making good the disturbed surface all as directed by Engr-in-charge
(a) MCCB Thermal Magnetic release,Ics=100% of Icu, Adjustable, 4 pole 125 Amps 16 KA.
(b) MCCB Thermal Magnetic release,Ics=100% of Icu, Adjustable, 4 pole 160 Amps 36 KA.
S&F sheet metal enclosures for distribution board when MCB to be used TPN (Triple pole and neutral) 4 way, 415 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, single door type complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used TPN (Triple pole and neutral) (4 way -UVPro), 415 Volts, sheet metal powder coated, IP 65 protection with 200 Amps rated bus bar, single door type & water proof ,dust proof complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 08 way, 240 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, single door type complete all as specified and directed.
S&F MCB SPN, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete.
Supply, fixing, testing and commissioning of MCB TPN/ FP, 40 to 100 Amp, 415 volts 10KA 'B' curve complete.
S&F MCB SPN 40 to 63 AMP 240 Volts, rupturing capacity 10 KA "C" Series complete.
Supply ,laying and fixing in trenches / wall / pole wich complete acceseries GI tube light grade 32 mm bore from ground to DB with suitable size clamp complete ,nut bolt ,washers .
M & L for cable jointing kit for LT 1.1 KV straight through joint 95 sqmm, 3.5 core, heat shrinkable type with all accessories as specified & directed
M & L for cable jointing kit for LT 1.1 KV straight through joint 70 sqmm, 3.5 core, heat shrinkable type with all accessories as specified & directed
M & L for cable jointing kit for LT 1.1 KV straight through joint 50 sqmm, 3.5 core, heat shrinkable type with all accessories as specified & directed
M & L for cable jointing kit for LT 1.1 KV straight through joint 35 sqmm, 3.5 core, heat shrinkable type with all accessories as specified & directed
M & L for cable jointing kit for LT 1.1 KV straight through joint 25 sqmm, 4 core, heat shrinkable type with all accessories as specified & directed
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TENDER83518.pdf
Tender Documents • 0.57 MB
PS8358.pdf
Tender Documents • 0.87 MB
LISTOFMAKE.pdf
Tender Documents • 0.20 MB
BOQ_828713.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .