Over Houling of Existing Sewerage Pumping Station Providing & Fixing Pumping Machinery with Safety Grill, Installation at Bhuj Nagarpalika, Dist: Katch (2nd Attempt)
308729
2026-27
Open
Civil - All
Kutch
2 documents required · 2 mandatory
₹6,000
Chief Officer Bhuj Nagar Palika, Bhuj
₹3.9 L
26 May 2026
26 May 2026
26 May 2026
29 Jun 2026
26 May 2026
NAME OF WORK :- Over Houling of Existing Sewerage Pumping Station Providing & Fixing Pumping Mashinary with Safety Grill,
Instalation at Bhuj Nagarpalika, Dist: Katch
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Providing and supplying D. I. K-9 grade pipes for following nominal bore diameter
with internal cement mortar lining including all taxes, insurance, transportation,
freight charges, octroi, inspection charges, loading, unloading, conveyance to
departmental stores, stacking etc. complete. (IS - 8329 / 2000) Rate for DI pipe
based on wholesale price index of Pig Iron as 157.60 for the month of Dec-2022. For
sewerage project cement mortor lining shall be with sulphate resistance cement
225.00 100 MM DI Pipe K-9 D/F 2120.00 RMT
110.00 150 MM DI Pipe K-9 D/F 2986.00 RMT
88.00 200 MM DI Pipe K-9 D/F 3898.00 RMT
50.00 300 MM DI Pipe K-9 D/F 6546.00 RMT
10.00 450 MM DI Pipe K-9 D/F 12515.00 RMT
Providing and supplying D. I. pipes for following nominal bore diameter with internal
cement mortar lining including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to departmental stores,
stacking etc. complete. (IS 8329-2000).
3620.00 200 MM DI Pipe K-7 1880.00 RMT
250.00 450 MM DI Pipe K-7 5418.00 RMT
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Manufacture, Supply & Delivery of Ductile Iron Flange socket spigot bends, tees,
reducers or any other specials as per BS-EN-545/1995 Class-A series K12 suitable for
use with D.I. Pipes manufactured as per IS:8329/1994 delivery of specials is to be
made to GWSSB store or site of works any where in Gujarat including all taxes,
loading, unloading, carting, stacking, insurance, inspection charges, octroi etc.
919.73 Socket & Spigot type 80 to 300 mm dia 148.00 KG
179.40 Socket & Spigot type 350 mm dia & above 151.00 KG
6800.00 DI Specials (DI bend , Tee, etc.) 148.00 KG
760.00 DI Specials (DI bend , Tee, etc.) 151.00 kG
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all
with shoring and struting if required as per required gradient and line including
safety provisions using site rails and stacking excavated stuff including up to all
required lead cleaning the site etc. complete for all lifts and strata as specified. Upto
a)Excavation for pipe line trenches 0 to 1.5 m Depth Ordinary soil & Soft Murram
319.60 b) Hard murrum 155.25 CMT
1026.80 c) Soft Rock 187.45 CMT
639.62 d) Hard Rock / C.C Road 427.80 CMT
Providing and making flanged joints to flanged DI /C.I. pipes of all classes /specials
etc. includingcost of all jointingmaterials rubberpacking, nut bolts, inclduing
lowering laying jointing labour hydraulic testing etc. complete.
225.00 100 MM DI Pipe K-9 D/F 548.55 RMT
110.00 150 MM DI Pipe K-9 D/F 702.65 RMT
88.00 200 MM DI Pipe K-9 D/F 962.55 RMT
50.00 300 MM DI Pipe K-9 D/F 1406.45 RMT
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
10.00 450 MM DI Pipe K-9 D/F 2450.65 RMT
Lowering, laying and jointing C. I. S & S Spun pipes suitable for Tyton joints / Mortar
lined D. I. Pipes of various classes with CI / MS specials of following diameters in
proper position, grade and alignment as directed by Engineer-in-charge including
hydraulic testing etc. comp.
3620.00 200 MM DI Pipe K-7 113.85 RMT
250.00 450 MM DI Pipe K-7 304.75 RMT
Refilling the pipeline trenches incl. ramming, watering, consolidating desposal of
surplus stuff as directed within a radius of 3 km.
Providing and fixing 50cm wide M.S. Ladder fabricated from M.S. Flats 10mm x75
mm with 20 mm dia steel bar steps in double rows, @30cm C/C. The include stays of
160.00 10mm x 50mm flats fixed at 3 meter C/C with welding anchoring and 3 coats 2950.00 RMT
anticorrosive paint.
Supply, installation, testing & commissioning of sewage submersible, non clog type
suitable for working on three phase, 50 Hz ± 3%, 415 V ± 10%, AC supply, 1450 RPM
synchronous speed with 3 core flat copper cable from pump to starter panel with
cable end terminations, all supports, clamps, pipe fittings along with mechanical
seal, bearing bush, strainer etc. complete set & following M.O.C: Casing: CI,
Impeller: SS CF8M, Wearing ring & Bearing bush: Bronze, TC mechanical seal, CS / SS
bearing, SS shaft with sleeve, SS strainer & MS motor body.
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
DOL / Star Delta starter suitable for local & remote pump control application
consisting of MPCB, overload relay and contactors as per Type II coordination
including digital voltmeter, analogue ammeter with selector switch, run hour meter,
required protective relays & control accessories.
20 DOL/SD 10 HP 9128.00 NOS
6 DOL/SD 15 HP 11119.00 NOS
2 DOL/SD 20 HP 13771.00 NOS
Auto Transformer Starter suitable for local & remote pump control application
consisting of Auto tansformer (vacuum impregnated, air cooled having three (3)
appings at 50%, 65% and 80%), incomer MCCB / PCB, overload relay and
contactors as per Type II coordination including digital MFM with RS
communication port, analogue type ammeter with selector switch, run hour meter,
required protective relays & control accessories.
2 A. T. S. from 30 HP 24276.00 NOS
2 A. T. S. from 40 HP 33403.00 NOS
1 A. T. S. from 50 HP 37804.00 NOS
2 A. T. S. from 60 HP 46238.00 NOS
Add for providing indicating & measuring instruments complete with accessories,
associated wiring & controls of following type & rating 3 Phase, 4 Wire
Multifunction Meter, Class 1.0 or better, Flush Mounting 96 x 96 mm with RS
communication port for Incoming(s) / Outgoings(s), as required.
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Add for providing indicating & measuring instruments complete with accessories,
associated wiring & controls of following type & rating On / Off / Trip, Control
Supply ON/ Healthy Indicating lamps (24 / 110 V DC or 110 V AC) for MCCB
90 controlled Incomming/ Buscoupler module(s). 634.00 NOS
Above 16 A, upto & including 80 A, 3 & 4 Pole, Air Break Fixed MCCB conforms to IS/
IEC 60947-2 with trip free mechanism, current limiting type with Thermal Magnetic
/ Microprocessor release (O / C, S / C & E / F) with adjustable settings & having
minimum 2NO+2NC potential free auxiliary contacts with all necessary Electro-
11 Mechanical protections & interlocks etc. MCCB module, when used as Outgoing(s), 20607.00 NOS
shall have enclosure dimensions- 300(H) x 500(W) x 600 (D) & following technical
features: 3 Pole, MCCB with Breaking Capacity of Icu=50 KA at 415V (Ics =100% of
Icu), TM release
Providing Chain pulley block with triple gear arrangement, lifting hook, laod chain &
hand chain & locking device etc
13 1 T Manually Operated 6 m 17400.00 SET
96 Additional lift 1 m 840.00 RMT
Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest
Edition) of following class and diameter including all taxes, insurance,
transportation, freight,charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc. complete. PN-1.6 With hand wheel
/cap operated (Alt 1 type long body)
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Providing and Supplying ISI Mark CI D/F Valves as per IS : 5312 (Latest Edition) of
following class and diameter including all taxes, insurance, transportation,
freight,charges, octroi, inspection charges, loading, unloading, conveyance to
departmental stores, stacking etc. complete. Reflux valves PN 1.6 IS 5312 with ISI
Lowering, laying and jointing in position following C. I. / D/F Reflux valves, Butterfly
valves, Sluice valves and Air valves including cost of all labour, jointing material,
including nut bolts and giving satisfactory hydraulic testing, etc. Complete . Suice
valves, Butterfly Valves, Reflux Valves
Supply, laying, testing & commissioning of 1.1 kV grade, XLPE insulated, stranded
Copper conductor, galvanised steel flat strip / round wire armoured, extruded PVC
type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary
clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road
crossing or floor as per site requirement) conforming to IS: 7098 (Part-1) & IEC:
(Part-1) of following sizes:
160.00 4 Core x 16 Sqmm 423.00 RMT
380.00 4 Core x 50 Sqmm 1308.00 RMT
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Dewatering by pumping set required capicity including temporary platform carting
pumping at site and fixing the same in position including all accessories, fuel and
labour etc. complete.
Float/ Displacer Type Level Switch: Design, Supply, Installation, Testing and
Commissioning of Top mounted Displacer Type level switches with 2 nos SPDT
contacts of Micro switch rated 5 A, potential free power supply, Material of wetted
parts shall be SS 316 and the material of accessories shall be SS. IP 65 or equivalent
degree of protection for enclosure, suitable for sump, ESR, tank, vessels and
31 underground reservoirs. The top mounted level switches shall be supplied with still 12802.00 NOS
tubes to suit the requirement. Accessories like name plate, mating flange, gaskets,
fasteners, bolts & nuts, etc. shall be supplied with the Level Switch of following
Fuse 3 Phase wiring, coupiling jointing cable fixing in wooden board and other fitting
10 accessories including satisfactory testing (each wooden board 4 nos fuses) 10000.00 JOB
Purchasing & supplying at site of works, with Railway freight, loading, unloading,
carting, etc. complete such as joints, channels, angles, iron rails, etc. Angles &
channels below 10 mm thickness
2.85 Angles & channels below 10 mm thickness 64838.00 MT
1.94 M. S. Flats of various thickness 66408.00 MT
Labour charges for lowering laying, erecting, fixing,various size of M.S. section such
as joints channel, angles plates etc. complete.
2.85 a) Angles & channels below 10 mm thickness 9801.45 MT
1.94 b) M. S. Flats of various thickness 13069.75 MT
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Painting two coats (including priming coat) on new steel and other metal surface
with enamel paint, brushing, interior to give an even shade including cleaning the
surface an even shade including cleanicn the surface of all dirt, dust and other
foreign matter.
Finishing wall with water proofing cement paint of on wall surfaces (Two coats) to
give an approved brand and manufacture and of required shape even shade after
thoroughly brushing the surface to remove all dirt and remains of loose powered
2125.00 materials. every subsequent coat of water proofing cement paint of approved brand 93.88 SQM
and manufacture.
Distempeing (Two coats) with oil bound washable distemper of approved brand and
manufacture and of required shade on wall surfaces to give an even shade, over and
including a priming coat with alkali resistance primer of approved brand after
thoroughly brushing the surface and other foreign matter and also including
preparing the surface even and sand parpered smooth.
Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI
740.00 marked copper wires of following size to be erected as directed. (i) 2.50 Sq.mm 4 107.06 MTR
core round PVC sheathed
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Providing and cast in situ C.C. in grade M 30 proportions of ingredients as permix
design by weigh batching using granite, quartzite trap metal of size 12 mm to 20mm
and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated
consolidation, curing and hydraulic testing etc. complete (excluding cost of
39.30 reinforcement) with centering and shuttering /de shuttering etc.comp. upto 6 meter 8213.00 CMT
height /depth Av. G.L.for all water retaining structures, Flat bottom slab/floor
slab/slab with shuttering
Providing the gunniting to interior surface of cement / masonry / Water Tank of
various capacities as specified at various places with cement mortar (1:2) in
thickness of 40 mm including chiselling and scraping loose concrete and plaster incl.
providing and fixing in position 6 mm dia. mild steel bars reinforcement at 15 cm c/c
both ways including fabricating and cost of binding wires including centering
24.00 staging all equipments etc. complete including scaffolding , carting of all type of 547.32 SQM
material and equipments to site of work and giving hydraulic testing up to
satisfaction of engineer in – charge . For top , bottom of ESR/ GSR/tank /cistern - for
Drilling 40 mm Dia. Holes in masonry/concrete structures with providing and fixing
290.00 500 mm long GI Pipeline for pressure grouting including supply of material, 458.04 RMT
machineries and labour cost etc. complete.
Demolition including stacking of serviceable materilas and disposal of unserviceable
materials with all lead and lift. (i) R.C.C. work
Providing and laying cement concrete pavement (25mm to 50mm thick) with 1:2:4 (1-
16.00 cement : 2-coarse sand : 4-stone aggregate 20mm nominal size) including finishing 4503.67 CMT
with floating coat of neat cement complete.
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Filling available excavated earth (excluding rock) in trenches. plinth, sides of
1435.50 foundations etc. in layers not exceeding 20 cm. in depth consolidating each 136.92 CMT
disposited layer by ramming and watering.
Providing and fixing EZ-7 section door/window frame including welding and fixtures
158.20 fastenings including 3 coats of approved enamel oil paint etc complete. 2378.49 CMT
Supplying & erecting single phase approved make industrial exhaust fan suitable for
medium duty ring mounted low noise operation suitable for medium duty having
12 following dia size and maximum speed in RPM [E] 450 mm dia 1400 RPM Cat-II 3937.99 NOS
Supply, testing & commissioning portable diesel driven self priming horizontal mono
dewatering pump set with four wheel trolley , GI medium duty delivery pipes,
6 specials, suction strainer etc. complete set Material of Constructions: Impeller: 30864.00 NOS
Bronze, Casing: CI, Shaft: Carbon Steel
Manufacture, supply and delivery of following ISI marked HDPE pipes (IS:4984/1985
with latest amendment) having material Grade PE-80 in approximate 100 meter coil
length or as per GWSSB requirement with SS 316 nipple at both ends having 11 TPI
270.00 threadsasper specifications, press fitted and bolted having nominal diameter as 392.00 RMT
under as per detailed technical specifications.
Designing (aesthetically) and constructing R.C.C frame structure of panal room with
Negative suction ,Without Gantry structure (Upto 3.60 M)
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Providing and cast in situ C.C. in grade M-30 proportions of ingredients as permix
design by weigh batching using granite,quartzite trap metal of size 12 mm to 20mm
and or 6 mm to 12 mm including scaffolding centering formwork, needle vibrated
consolidation, curing and hydraulic testing etc. complete (excluding cost of
4.26 reinforcement) with centering and shuttering/deshuttering etc. comp. upto 6 meter 8412.00 CMT
height /depth Av. G.L.for all water retaining structures ,Vertical Wall ,Above 15 cm
and up to 20 cm
Supplying cutting, bending, binding and placing in position steel as per planand
design and as per ISS 2502 including cost of steel and binding wire for reservoirs/
0.85 structures only including lift upto 6 meter height or depth below G.L. for all 77504.00 MT
diameters ,deformed (TMT) bars confirming to relevant ISFe–500 grade for all
Puming Station in all pipe, Motor remove and new Pipe Fitting & all necessaries
fiting accessories etc. complete for Fitting.
Labour charges for cleaning of sump/GL cistern including cleaning and removing
algae, calcinations, sludge, dirt deposition from bottom and as well as fromwall of
9 container, disinfection by bleaching powder with all necessary tools and plants, 1707.00 NOS
labours and cost of disinfectant etc complete
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Providing and casting in situ C.C. in grade M-15 (approx. corresp. to prop. 1:2:4)
(proportions as per mix design or as per Table 9 of IS 456 2000 in masses by weigh
batching) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work,
including scaffolding centering, formwork, needle vibrated consolidation, curing
64.00 comp. up to 6 meter depth or height (excluding cost of reinforcement and neat 4732.00 CMT
finishing) with centering and shuttering / deshuttering etc.comp. for structure for
other than water retaining.
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Preparing structural design of RCC Under Ground / Partially under ground / above
high ground level Reservoir of required capacity as per relevant I.S. standards and
constructing the same, including excavation in all types of soil strata (including rock)
including shoring strutting if required, for loose soil / to protect from collapse,
casting 100 mm thick P.C.C. levelling course in M15, Refilling the pit with proper soil
and disposing of the surplus stuff at all lead. Including cement plaster in CM 1:2 with
approved water proofing compound to all over inside container (i.e. walls, base, top
slab/dome bottom etc. all). Including all types of labour and material charges of
lowering, laying, erecting / hosting and jointing of pipe assembly to inlet, outlet
overflow, washout and bye pass arrangement as per hydraulic design. Providing and
fixing accessories, CI Manhole frame and cover, water level indicator, adequate cowl
type ventilators or lantern type ventilator with stainless steel jail. RCC chambers for
valves. Providing and applying three coats of cement paint / snowcem to the out
side face of structure. It also includes satisfactory water tightness test as per
relevant I.S. code and painting name of scheme and capacity on the tank as per
direction of engineer in charge.List of Indian Standards for Design of GSR /
SUMP:The structural design of GSR shall be in accordance with provisions relevant
I.S standards (1) I.S. 3370 part I & II 2009 or Its latest revision(1.1) I.S. 3370 part III &
IV 1965 or Its latest revision(2) I.S. 456 – 2000 or Its latest revision.(3) I.S. 1893 –
2000 – 1984 or Its latest revision. (4) I.S. 875, Part – 1 to 3, 1987 or Its latest
revision. General Specifications:(1) Water depth in container shall be adopted as per
data of tender. Capacity shall be calculated excluding free board of the reservoir. If
water depth is not specified, the suitable water depth / acceptable to field engineer
in accordance with hydraulic (2) Shape of container (in plan) specified by in data
shall be adopted in absence circular shape shall be adopted. (3) Size shall be fixed as
per availability of space (land area) at site / acceptable engineer in charge. (4) Effect
of overlapping of pressure bulbs on soil due near by structure and proposed sump
should be considered. (5) Care shall be taken that no damage should occur to nearby
existing structure. Compensation shall be paid for the same by agency.(6) The
minimum concrete grade for RCC shall be M-30.(7) HYSD Fe 415 / 500 grade
reinforcing bars confirming to I.S. 1786 / 1139 shall be considered in design. CRS /
TMT bars shall be provided. In saline atmosphere corrosion resistance stainless steel
/ HCR rebar shall be provided. Any other steel can be used with approval of C.E./ in
situation of non availability in market without extra cost. (8) Minimum size (or
thickness) of various components shall be provided as per tender criteria /
specifications in absence as per I.S./ Std. practice of G.W.S.S.B. Minimum dimensions
specified for various components in tender data / specifications shall be provided
without fail.(9) The safe bearing capacity (SBC) shall be referred from SBC test
report. In absence of report it shall be referred from data sheet. If poor soil is found
/ water table is met with during excavation SBC shall be scientifically ascertained and
I.S standards (1) I.S. 3370 part I & II 2009 or Its latest revision(1.1) I.S. 3370 part III &
IV 1965 or Its latest revision(2) I.S. 456 – 2000 or Its latest revision.(3) I.S. 1893 –
2000 – 1984 or Its latest revision. (4) I.S. 875, Part – 1 to 3, 1987 or Its latest
revision. General Specifications:(1) Water depth in container shall be adopted as per
data of tender. Capacity shall be calculated excluding free board of the reservoir. If
water depth is not specified, the suitable water depth / acceptable to field engineer
Quantities in accordance with hydraulic (2) Shape of container (in plan) specified by in data Tendered Rate
estimated but shall be adopted in absence circular shape shall be adopted. (3) Size shall be fixed as
Item of work Unit according to
per availability of space (land area) at site / acceptable engineer in charge. (4) Effect Rate in Figure estimated quantities
of overlapping of pressure bulbs on soil due near by structure and proposed sump
should be considered. (5) Care shall be taken that no damage should occur to nearby
existing structure. Compensation shall be paid for the same by agency.(6) The
minimum concrete grade for RCC shall be M-30.(7) HYSD Fe 415 / 500 grade
reinforcing bars confirming to I.S. 1786 / 1139 shall be considered in design. CRS /
TMT bars shall be provided. In saline atmosphere corrosion resistance stainless steel
/ HCR rebar shall be provided. Any other steel can be used with approval of C.E./ in
situation of non availability in market without extra cost. (8) Minimum size (or
thickness) of various components shall be provided as per tender criteria /
specifications in absence as per I.S./ Std. practice of G.W.S.S.B. Minimum dimensions
specified for various components in tender data / specifications shall be provided
without fail.(9) The safe bearing capacity (SBC) shall be referred from SBC test
report. In absence of report it shall be referred from data sheet. If poor soil is found
/ water table is met with during excavation SBC shall be scientifically ascertained and
design shall be revise. No extra shall be paid for increase in quantity. (10) DI pipes
and special shall only be used if type is not specified in tender.(11) The rate shall
include cost of dewatering during excavation making all arrangement when water
table meets within depth.(12) The structure shall be designed properly to resist
uplift due to ground water table specified in data or actual ground water table
meets with during excavation. If GWT / Uplift is mentioned in tender and during
excavation it dose not meet 7.5% rate shall be reduced. (13) SS pipes railing shall be
provided over sump perifery when sump height is ≥ 1.5 meter above ground level.
(14.a) RCC staircase/RCC Steps should be provided from GL to sump top slab based
on the height of the GSR above/below the ground. (14.b) RCC Staircase with SS
railing to be provided inside reservoir container. BB Masonry staircabin to be
provided to cover the same with MS safety door having locking arrangement. (15)
Appearance of structure should be aesthetically good looking acceptable to
authority. (16) Any change in size, shape, depth below GL, height above GL, water
depth, F.B., size of member etc can be permitted in exceptional case due to site
condition or hydraulic design requirement by C.E. No extra shall be paid for change.
(17) Any change in data, dimensions, shape, water depth, reduction in size if
permitted by competent authority and if it reduces quantity then payment shall be
reduced prorate. (18) When capacity of GSR / Sump is > 20 lakh litres two or suitable
compartments acceptable to executive engineer shall be designed and provided.(19)
Agency shall engage qualified (at least graduate) consulting engineer for designing
the structure and he / she shall visit the site for guidance of work.(20) 75% part rate
shall be payable for concrete, reinforcement and plastering items of container until
satisfactory hydraulic testing for water tightness is performed as per tender
condition. Till the work shall be treated as incomplete.Above conditions / general
specifications Sr. No. 1 to 20 are part and parcel of tender (contact) and prevail over
other provisions in tender. Note: For GSR (U/G sump) with cover slab to be
constructed at site situate in seismic zone V, the above rates shall be increased by
meets with during excavation. If GWT / Uplift is mentioned in tender and during
excavation it dose not meet 7.5% rate shall be reduced. (13) SS pipes railing shall be
provided over sump perifery when sump height is ≥ 1.5 meter above ground level.
(14.a) RCC staircase/RCC Steps should be provided from GL to sump top slab based
on the height of the GSR above/below the ground. (14.b) RCC Staircase with SS
railing to be provided inside reservoir container. BB Masonry staircabin to be
Quantities provided to cover the same with MS safety door having locking arrangement. (15) Tendered Rate
estimated but Appearance of structure should be aesthetically good looking acceptable to
Item of work Unit according to
authority. (16) Any change in size, shape, depth below GL, height above GL, water Rate in Figure estimated quantities
depth, F.B., size of member etc can be permitted in exceptional case due to site
condition or hydraulic design requirement by C.E. No extra shall be paid for change.
(17) Any change in data, dimensions, shape, water depth, reduction in size if
permitted by competent authority and if it reduces quantity then payment shall be
reduced prorate. (18) When capacity of GSR / Sump is > 20 lakh litres two or suitable
compartments acceptable to executive engineer shall be designed and provided.(19)
Agency shall engage qualified (at least graduate) consulting engineer for designing
the structure and he / she shall visit the site for guidance of work.(20) 75% part rate
shall be payable for concrete, reinforcement and plastering items of container until
satisfactory hydraulic testing for water tightness is performed as per tender
condition. Till the work shall be treated as incomplete.Above conditions / general
specifications Sr. No. 1 to 20 are part and parcel of tender (contact) and prevail over
other provisions in tender. Note: For GSR (U/G sump) with cover slab to be
constructed at site situate in seismic zone V, the above rates shall be increased by
150000.00 Cost above 200000 up to 500000 Ltr 2.89 LTR.
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Supplying & erecting earth pit of minimum bore dia.150mm size approved make
Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of
corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved make OEM has to
submit test certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure the value of
earthing resistane mentioned in test Certificate) & having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC
50 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) 8636.51 NOS
Back fill Compound :- Earthing compound should be capable to retain moisture for
long time Necessary test report must be submitted by Agency. (c) For Electrical
Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant &
Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be erected concealed
in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of following size (C) With oval
conduit /PVC casing capping double lock type
500.00 (c) 3 wire 1.5 sq. mm 76.76 MTR
500.00 (d) 3 wire 2.5 sq. mm 95.95 MTR
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up
to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell
push & accessories and earth continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame covered with
124 textured/metallic/white front plate modules erected on / in wall / ceiling as per 449.45 NOS
pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling
complete cat-III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of
ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected with following type of
26 accessories. [I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby 475.71 NOS
switchboard/mcb db board (a) with medium class Rigid PVC pipe and accessories
erected flushed on wall/ceiling complete cat-III
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of
ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected with following type of
accessories.[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from
mcb db board. (a) with medium class Rigid PVC pipe and accessories erected flushed
on wall/ceiling complete cat-III
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and
high U.V. & corrosion resistance with diffuser with company mark/name 160V to
270V, Power Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt ,LED LED driver efficiency > 85 % ( fitting required LM-79
72 & LM-80 Certificates) (NOTE: Below description have shown ranges of Wattage 373.70 NOS
capacity of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.) (A) Tube Light with integral driver (iv) 22-24 Watts,
Surge - 2KV,IP-20, conventional 4 feet
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Supplying and erecting LED street light / Flood light fittings with High power White
LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED
45 driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below 6088.28 NOS
description have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.) (B) Flood
Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line
supply with over-voltage protection. (iii) Above 60 to 90 watts Cat-lll
Supplying and erecting B class galvanised iron pipe 32 mm outside dia 45 cm long
duly welded on 20 cm x 20 cm x 3 mm thick M.S. base plate, erected on wall or
39 corner for mounting street light luminaire with necessary hardware materials duly 343.40 NOS
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve)
having 10 KA breaking capacity & confirms to IS : 8828 in existing box having
18 following capacity (A) 6 to 32 Amp. Cat.III 278.76 NOS
Plastic enclosure fitted with DIN rail suitable for incorporating Three /Four nos. MCB
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following
capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts
grouted in wall complete. [B] For 5.5 / 6.5 KG Capacity
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due
burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid)
12 adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. 299.97 NOS
(All above contents shall be of standard makes)
Providing and fixing printed instruction chart both in English and Gujarati and duly
14 framed with front glasses, for treatment of person suffering from Electric shock with 130.29 NOS
minimum 50" diagonally size.
Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I.
sheet with extra handle at bottom duly painted white inside and Red out side with
14 FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall 214.12 NOS
Supplying and erecting floor mounting stand for keeping four nos. of FIRE buckets
comprising 1500 mm in length, 900 mm height frame made out of 30mm X30 mm X
14 4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted 942.33 NOS
with one coat of red lead and two coats of approved enamelled silver paint.
Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (b)4mm
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Supplying rubber matting of following thickness as per IS:15652/IEC 61111 (c)12mm
Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply.
Supply and Install Solar CCTV Camera (Trueview solar camera T18164- AF(with
memory card), Product cod :- T18164 (BQ3A-GBM2), Technical Specifications Image
Sensor :- 1/2.8” CMOS Sensor Resolution :- 3MP, Video Compression Standard :-
H.264+ / H.265 / H.265+ , Infrared IR Distance :- 30 Meters , White IR Distance :-
Meters , Light Mode :- Full color / Infrared , Minimum Illumination :- Color : 0.01Lux,
Black and White : 0.001 Lux , Monitoring :- Android & iPhone / Windows PC
23 (Application Truecloud) , Storage :- Support Micro SD card (Max 256G), Solar Panel :- 36360.00 NOS
7W , Built in Battery :- 18000mAh Rechargeable , Power Supply Input :- DC 5V-2A
[Type-C], Power Comsumpution :- ≤8W , Working Temp :- 0~50oC RH Less than 95%
(No condensation), Dimension :- 132 x 191 x 170mm (WxHxL) , Net Weight :-
0.856.4kg , Gross Weight :- 1.9478kg,
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Design, Supply, Installation, Testing, Commissioning of Full Bore Electromagnetic
flow meter with factory calibration, Inbuilt Battery Power Operated, flanged
connection, Flow sensor, Indicator, transmitter and totaliser with all accessories viz.
surge arrestor, associated cables, cabinets, hardwares, etc complete as per following
specifications: DC pulsed type, IP 68 Protection, Flanged process connection as per
IS 1538 or equivalent standard, SS304/ Metallic Alloy Flow Tube, SS316/ SS 316 L/
Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/ Inbuilt Grounding Electrode,
Neoprene/ Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die Cast Aluminium/
Carbon steel with Anticorrosive Paint Coil Housing with Junction Box, CS flanges.
Microprocessor based, Modular design, 2 line LCD for indication of actual flow rate,
forward, reverse, sum totaliser display, ±0.5% accuracy at 0.3 to 4 m/sec velocity,
one scalable pulse/ one status, one Modbus output, one GPRS/ GSM output, IP
protection, Die cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/ PU
finish with glass window enclosure, Inbuilt EEPROM and Data Logger, 20 meters
cable length for sensor to transmitter communication, Minimum 5 years battery
lifetime, 3.6 VDC Non Rechargeable Lithium-thionyl chloride/ Ni-Cd high power
batteries, Hourly Basis Worldwide transmission of measured data and events via
e‐mail and SMS by integrated GSM/GPRS modem, Reliable data storage facility
through integrated SD card etc alongwith wall mounted/ stand mounted cabinet.
Full Bore Electromagnetic Flow Meter (Inbuilt Battery Power Operated)- PN
200mm Nominal Bore
1 450mm Nominal Bore 294706 NOS
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Drilling of 500 mm dia Horizontal bore hole for watermain pipeline under the railway
tracks incl all strata with requried length including fixing of 400 mm dia M.S. casing
pipe of minimum 6 mm thick with welding pushing etc complete Providing & fixing
various size of pipe for 193.7 mm /219.10 mm /244.5 mm dia watermain of G.I/M.S
pipe of minimum 6.3 mm thick for railway permises as per instruction & regulations
of Railway authority & under supervision of Railway authority incl Provinding,
supplying & fixing of spacerat specified interval if required between Casing pipe and
water main, ISI make sluice valve of required size at both side of railway boundry
2 with construction of brick edge pavement incl C:C encasing 1:3:6 in 10 mtr length of 407844 NOS
pipe at both side. Incl provinding & fixing of M.S/Iron Manhole frame with cover for
valve chamber with loacking arregment etc. complete with all material labour
fabrication,hydralic testing of pipe & valve etc complete for 45 mt Length.which
includes horizontal pushing and with open excavation. Without Water main & with
Quantities Tendered Rate
Item of work Unit according to
Rate in Figure estimated quantities
Drilling of 500 mm dia Horizontal bore hole for water main pipeline crossing under
the road incl in all strata with requried length incl fixing of 400 mm dia M.S/RCC
1 casing pipe with pushing etc complete various size of pipe for 193.7 to 244.5 mm dia 358789 NOS
water main (For 45mt Length) Without Water main & with MS Casing Pipe-400
Note : gst will be paid as per government rules.
I/We am/are willing to carry out the work @............... % above/below ( Percent should be written in figures and
words ) The tendered amount mentioned above amount of my /our tender works out as under
Tendered amount Rs……………………….. Tendered amount Rs………………………..
Add ……...% above Rs…………………. Deduct ……...% Below Rs………………….
(Please strike out which ever is not applicable )
All work shall be carried out as per public works department handbook and other specifications of division or as directed.
Rates quoted inclusive of clearance of sight (prior to commencement of work and at its close) in all respect
and hold good for work under all conditions , sight, moisture, weather etc
one percent labor cess will be deducted from the valued work done as per ' Bulding and other construction
work welfare cess act' G.R. No. GHR - 2005/04/CWA/2004/841/M-3 Dt. 31/01/2005
Signature of the Contractor.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Standard Bidding Document Book.pdf
2.Invitation.pdf
3. Terms and Conditions.pdf
4. Sch-B.pdf
5.PQ Criteria.pdf
Download all tender documents and submit your bid