Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹22.2 L+₹3,680 (0.17%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | l3₹23.9 L+₹1.7 L (7.88%)Rejected-Finance | l3 | Rejected-Finance HIGHER RATE | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CAT b (i) |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
6 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY
BHUJ
CERTAIN EM WKS TO VARIOUS BLDGS OF POCKET B UNDER AGE EM OF GE A BHUJ
2024_MES_653495_1
8215
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹40,000
Yes
31 Aug 2024
11 May 2024
8 Jun 2024
11 May 2024
6 Jun 2024
24 May 2024
Amount
M&L for Disconnecting,taking down and removing of ceiling fan of any description, any sweep and from any position / locations and connecting up from ceiling rose or connector to ceiling fan, necessary oiling and greasing including supplying and replacing of damaged nuts, bolts, rubber seal , clamps and replacement of unserviceable parts if any, making necessary adjustment and proper alignment of blades, connecting to existing electric sources with using new 1.5 sqmm 3 core multistanded PVC insulated copperwire FRLS to required length and testing at site complete all as specified and directed. Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engr-in-charge of ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan complete all as specified and directed for the following Fans:- (a) Rewinding of motor of ceiling fans 1200/1400 mm sweep
Supply only bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans complete all as specified and directed.
Supply only bushes gun metal suitable for celling fans 1200/1400mm sweep of any size complete all as specified and directed.
Supply only rubber reel type synthetic rubberwith 14.5 mm hole suitable for hooks of celling fans complete all as specified and directed.
Supply only nuts, bolts and washers of appropriate size for hanging of celling fan including split pins of galvanished iron 1/8" dia, 2" length complete all as specified and directed.
Supply only top/bottom (Set of Two) canopy of required size complete with tightening screws complete all as specified and directed.
Supply only down rod 30cm long made out of heavy grade MS pipe with necessory threading at both ends holes as required with suitable matching colour of ceiling fan 1200/1400mm complete all as specified and directed.
Supply only condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFDcomplete all as specified and directed.
Supply only fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of suitable for ceiling fan complete all as specified and directed.
Supply and fix in replacement of BLDC fan PCB(Control board ) complete all as specfied and directed.
M&L for Painting of celling fan 1200/1400mm sweep AC 230 volts single phase complete in site or at contractor workshop with synthetic enameled white/maching paint by spraying one coat including filling of cavities after cleaning all dust complet all as specified and directed.
Description all as per sil item No 1 here in before but for exhaust of any size/make complete all as specified and directed. Note : (i) The unserviceable winding / bearing or any parts shall be paid measured and paid for separately as "supply only" under appropriate item of sch "A" . (ii) Burnt out windings replaced and paid for separately under appropraite item of Sch 'A' . (iii) Labour charges for fixing of items which is mentioned here - in - after as supply only is deemed to be included quoted rate.
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete all as specified and directed.
Supply only ball bearing suitable for exhaust fan 300 to 450mm sweep of different make, complete all as specified and directed.
Supply only exhaust fan frame made out of MS sheet for any make and size of exhaust fan with suitable size of nuts, bolts lugs and washers complete all as specified and directed.
M&L for Painting of exhaust fan 300 to 450 mm sweep AC 230 volts single phase complrtr with synthetic enameled white/grey/matching paint by spraying one coat including filling of cavities after cleaning all dust complete all as specified and directed.
Supply only fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of exhaust fan complete all as specified and directed.
Description all as per item No 12 here - in - before but capacity 4 MFD for exhaust fan of approved make and quality complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers including making hole for fixing exhaust fan , the disturbed surface to be matched with existing complete all as specified and directed.
Supply and fix exhaust fan, plastic body AC single Phase. 230V of size 250 mm sweep with, blades, and frame and louvers including making hole for fixing exhaust fan , the disturbed surface to be matched with existing complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers including making hole for fixing exhaust fan , the disturbed surface to be matched with existing complete all as specified and directed.
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rate complete with all fixing acessories, temperature display complete all as specfied and directed.
supply and installation of 1 phase smart meter calss 1 Accuracy 230v 10-60A 50HZ, with CIU & STTD LCD type display, RS 232 Communication, as per IS code 1644:2020 complete all as specified and directed.
supply and installation of 3 phase smart meter calss 1 Accuracy 415v 10-60A 50HZ, with CIU & STTD LCD type display, RS 232 Communication,as per IS code 1644:2020 complete all as specified and directed.
M&L for testing of existing earthing by using fall of potential test and submit report, voltage between neutral and earth to be included in report complete all as specified and directed.
M&L for testing existing fire alaram system and submit report about the working and servicablity complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
M&L for earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth strip 32X6 mm by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point,all as specified and testing on completion, complete all as specified and directed. Note :- (i) The unit rate shall also included for earth work in hard /dense soil,PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing strip and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule. (iii) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (iv) On teting after completion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32×6mm dia galvanised steel strip complete all as specified and directed.
Supply and fix in repair single point air termination aluminium rod, 12 mm dia, 300 mm long complete all as specified and directed.
Supply and laying 40 mm bore galvanized steel tubing, medium grade (For fixing air termination rod as pipe post with all fittings laid in trenches / road / etc complete as all specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded aggregates as in copings(150x150x200 mm) for holding GI pipe kneelers, apex stones, bed plates, kerbs etc. water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed
Supply and fix test point termination block of size 75 mm x 75 mm x 25 mm made of Gun Metal or phospherous bronze drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw and box of size 90 x 90 x 90 mm (Made out of 1.6 mm thickplain brass sheet) and screwed to wall for protection of test point complete all as specified and directed.
M&L for comprehensive maintanence of earthing any type, tighting of nuts/bolts and welding to joint, replacing of funnel & wire mesh, watering with adding salt in adequate quantum, cleaning of surrounding area up to 3 m, repairing of earth pit & cover, earthwork including civil work complete all as specified and directed.
M&L for testing of internal wiring as per latest IS code conducting all test to ensure healthiness, report to be submitted on prescribed format, wiring diagram showing all circuit & marking with distinguish colour coding, displaying capacity of switch gear, location, checking of any current leakage, checking of E-N voltage,cleaning of DBs,refreshing of all conncetion using timbles, lugs, insulation tap, as follows:- 1) IR test. 2) Visual Inspection. 3) Continuity Test. 4) Leakage test. 2) Polarity test. 3) Earth Resistance test etc. The test report after completion testing shall be submitted to the department with duly signed by licensed electrican following current leakage/any fault in wiring. The report shall be given with proper format showing each circuit value of test done. Equipment to be used in testing should be calibrated, date of calibration to be displayed on the equipment and calibration report should be submitted. whatever defects found in internal electrification shall be endorsed in report with recommendation (The same can be made proper through replacement/repair)
M&L for testing of energy meter any type and capacity, on-site testing/lab testing through OEM/Govt lab/ Govt approved lab to make sure consumption being recorded energy meter properly, the report to be submitted along with previous retrieved data, proper records to be maintained at the time of taking out/re-fixing of meter, transporation to and fro, if energy meter found unservicable/defective the average consumption to be mention on the basis of retrived data in report for energy chargers, disconection & taking down and refixing complete all as specfied and dircted.
Notes :-(1) The contractor shall keep all items readily available at site, which is required for urgent repair works of appliances.
(2) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.
(3) All tools &tackles, plants, machineries, equipment and material to carry out the work at site to be provided by the contractor at his/ her own cost. Workshop shall be setup for rewinding/ repair of ceiling fan, exhaust fan, wall mounted fan, refrigerator, deep freezer & desert cooler etc. Rewinding machine should be installed in workshop with the latest configuration.
(4) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(5) The electrician on duty round the clock will have to be available at the site service centre created by the contractor & should have mobile phone. In case of absence of electrician, Rs 500/- will be levied as penalty for each instance.
(6) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm.
(7) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration.
(8) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(9) The date of repair, unit name & serial number shall be mentioned in neat sticker in the appliances after repair.
(10) Contractor is to collect the faulty appliances from units & return them after repair within a week. No separate charges shall be given for transportation.
(11) To carryout the serving of AC, refrigerator, deep freezer & water cooler, following T&P should be brought at site (service centre):-
(i) Drilling machine for making hole in wall.
(ii) Jet spray for cleaning of indoor and outdoor units.
(iii) Vacuum cleaner and blower
(iv) Ref mechanic tools kit
(12) It is responsibility of contractor to clean the area after repairwork of appliances. Rates are deemed to be include in his quoted rates of respective items.
(13) The same nature of complaints in same location shall be counted as one complaint in internal electrification. Job card and complaint register for entry of complaints shall be provided at his/ her own cost.
(14) Any of contractor persons causes damage of equipment or property of Militart station, the contactor will be solely held responsible for the cost of consequences thereof.
(15) Contractor shall identify the real cause of burned winding of fan motor. Winding problems that are identified should be documented. Then, winding of fan motors shall be cut/ removed completely in presence of officials. Rewinding of same shall be carried out with proper copper gauge wire.
(16) Job card /Docket shall be maintaned properly mentioning as below: a) service Number b) Name c) Rank d) unit e) Date Format of docket/job card shall be provided to contractor. Date of receiving & Date of resolving with time shall be endosrsed on job card.
(17) Joint measurement weekly. The contarctor should be availble for joint measurement along with supervisor on every Wednesday/as decided by Enginner-in-charge.
(18) Stationery such as complaint register, Job card/Docket , work diary ,hindrance register, site order register etc shall be supplied by the contractor
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
M/s Bombay Novelty Stores
Ashok Electric and Electronics
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .