Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹1.9 Cr+₹15.2 L (8.65%)Rejected-Finance | ₹1.9 Cr+₹15.2 L (8.65%) | L2 | Rejected-Finance Not lowest tenderer |
| 3 | L3₹1.9 Cr+₹16.9 L (9.63%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹1.9 Cr+₹16.9 L (9.63%) | L3 | Rejected-Finance Not lowest tenderer |
| 4 | L4₹2.1 Cr+₹29.6 L (16.8%)Rejected-Finance PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | ₹2.1 Cr+₹29.6 L (16.8%) | L4 | Rejected-Finance Not lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
13 Feb 2023, 6:00 pmClosed
CE(AF) GANDHINAGAR
LEKHWADA, PATIA, CHILODA, CRPF CAMPUS GANDHINAGAR
ADDN/ALTN/IMPROVEMENT TO CERTAIN SOFT PENS IN TECHNICAL AREA AT AF STN BHUJ
2022_MES_570828_1
87200
Open Tender
Civil Works
Item Rate
365 days
GE(AF)BHUJ
AS PER NIT TENDERS DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE(AF) BHUJ
₹2.7 L
Yes
25 Feb 2023
23 Dec 2022
14 Feb 2023
23 Dec 2022
13 Feb 2023
30 Jan 2023
24 Dec 2022 - 31 Dec 2022
Amount
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
Taking down cement plaster on brick or stone walls, Concrete surfaces, etc. including raking out joints hacking for key scrubbing down with water etc all as specified and as directed..
M&L Rendering 5mm thick in Cement Mortar 1:3 on Concrete Surfaces of Ceiling, etc., plastered surfaces finished Even and Smooth, without using Extra Cement, complete all as specified and as directed.
M& L Preparation of new plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed.
M& L Preparation of new plastered surfaces on ceilings and applying three coats of white wash complete all as specified and as directed.
M & L for rendering in cement mortar (1:6), 10 mm thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing surfaces finished even and smooth without using extra cement complete all as specified and directed
M & L GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and as directed.
Removing the pealed off portion from the RCC fins, parapet ceiling wall etc at any height including clipping cleaning with wire brush removing all loose particles making good the corroded rusted reinforcement and labour only for binding reinforcement by welding/tying with MS annealed wire not less than 0.90mm and guniting the area with minimum pressure of 5 Kg/Sq.cm to an average thickness of 25 to 30mm in CM 1:2 by using approved WPC @ 3% by weight of cement and finish the surface even and smooth without using extra cement all as specified and as directed.
M & L for applying one coat of Anti- corrosive primer as per manufacturers instructions to exposed old reinforcement to the full circumference and length of bars to form unbroken 40 micron thick film complete all as directed by the Engr-In-Charge (Make :- Nitozic primer of M/s Fosroc Chemicals or equivalent product as approved by GE)
Rough excavation n exc. 1.50 deep and getting out any type of soil all as specified and as directed.
Removing excavated material in soils exc. 1.50km but not exc 5.00Km and depositing where directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed.
Forming embankments including raising (or lowering) earth, spreding soil layers n exc 30cm thick, watering, ramming/rolling and finishing to required size, shape etc n exc 1.50m high from base complete all as specified and directed.
Item No.13 above but exc 1.50m High not exc 3.00m from base.
Item No.13 above but exc 3.00m High not exc 4.50m from base. Note item no 13 to 15:- The soil obtained from item no 10 & 79 shall be used for forming embankment. Minimum Lead of 500m deemed to be included in the quoted rates for excavated earth stocking and shifting the same to forming embankment.
M & L for rendering in cement mortar (1: 4), 15mm thick on on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing surfaces, finished fair and even, complete all as specified and directed.
M&L Rendering 15mm thick on Brick Work or Concrete Surfaces (in drain,External surface of wall etc.) in Cement Mortar 1:4, mixing with WPC as per Manufacturer’s Instructions, finishing Plastered Surfaces Even and Smooth without using extra Cement, complete all as specified and as directed. NOTE:- Water Proofing Compound (WPC) will be Measured and Paid separately under appropriate Item as 'Supply only'.
Supply only Integral Water Proofing Compound, conforming to IS 2465-1975 complete all as specified.
M&L for preparation of new or previously untreated concrete or PCC block masonry external surfaces and applying two coats of exterior emulsion paint (in camouflage pattern as approved by the GE) over a coat of primer all as specified and directed.
M&L Cement Concrete 1:2:4 type B1 (Using 12.5mm gradded aggregate) in surface Channels, etc. in Manhole including necessary Formwork (if required), complete all as specified and as directed.
M&L Extra forming Fair Finished to Drains or Channels 30 Cm Inner Girth in Cement Concrete using Extra Cement including Forms Moulds Mitred/ Stopped Ends, etc., complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (Using 40mm graded aggregate) as in foundation and mass concrete all as specified and as directed..
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specefied and and directed. Fe-410W (Gde E-250 quality 'A' )
Erection fixing only Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specefied and and directed.Fe-410W (Gde E-250 quality 'A' ). Note :- Taking down, removal and stocking included in item No 33.
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment ,Fe 410-W (Gde-E- 250) quality- A, all as specified and as directed.
S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified and as directed.
Fixing and Fabrication of Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified and as directed.
Mild steel screw bolts (machine made) dia 16mm to 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm long not exc 15cm complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping of lintels, cills, steps, other similar bands, lacing, pavapets etc including necessary form work, weathering slightly rounded or chamfered angles and throating complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and as directed.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (Coloured) having tensile strength of 550 Mpa as in roof covering/cladding to wall, curve/ circular portion on roof truss etc fixed with self tapping screws all as specified and as directed.
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick (Coloured) having tensile strength of 550 Mpa as in roof covering/cladding to wall, curve/ circular portion on roof truss etc fixed with self tapping screws all as specified and as directed. Note for item 31 & 32 :- The colour of pre-painted galvalume sheet shall be approved by GE. Contractor shall be procured the same only after written approval by the GE.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed.
M&L preparing old Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying two Coats of Synthetic Enamel Paint (First quality) complete all as specified and as directed.
M&L preparing New Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying two Coats of Synthetic Enamel Paint (First quality) over a coat of red oxide primer complete all as specified and as directed.
Demolition of PCC block masonry built in cement mortar any size, any height all as specified and as directed.
M&L for precast cement concrete block masonry type 1:3:6 using 20mm graded aggregate with solid blocks, exc 10cm in width and setting in CM 1:6 complete all as specified and directed
M&L R.C.C M30 (design mix) as in Columns, pillars, piers, posts and struts all as specified and as directed.
M & L Formwork to sides of concrete columns pillars, piers, posts and struts etc for rough finished surfaces of concrete all as specified and as directed.
M&L R.C.C M30 (design mix) as in Beams, cantilevers, bressummers,lintels over 1.5m span all as specified and as directed.
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, helves including sup- ports, overhangs,etc. also splays between floors and beams, etc.for rough finished surfaces of concrete complete all as specified and as directed.
M&L R.C.C M30 (design mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed.
M&L formwork to faces of walls, flat retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter as specified and as directed.
S & F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. Note :- Quoted rate is deemed to be included for re-baring and welding with existing reinforcement and applying one coat of anti-corrosive primer ( Nitozic primer of M/s Fosroc chemicals or equivalent as approved by GE) on steel reinforcement as per manufacturers instructions and as directed by GE.
S & F TMT Mild steel bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. Note :- Quoted rate is deemed to be included for re-baring and welding with existing reinforcement and applying one coat of anti-corrosive primer ( Nitozic primer of M/s Fosroc chemicals or equivalent as approved by GE) on steel reinforcement as per manufacturers instructions and as directed by GE.
Expanded metal, not exc 4.00 Kg per SQM, and 25mmx25mm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed.
M&L hard core of guage n.exc 63mm deposited, spread, levelled in layers n.exc 15cm thick, watering and rammed to required to a true surface complete all as specified and directed.
M&L 100mm thick PCC (1:4:8) type D2 (using 40mm graded aggregate) as in sub base complete all as specified and directed.
M&L 100mm thick PCC (1:2:4) type B-1 (using 20mm graded aggregate) as in sub base complete all as specified and directed.
M & L for Forming construction joints (Dummy) 65mm deep x 10mm wide filled with sealing compound grade B complete all as specified and as directed.
Demolition of Reinforced Concrete of any description and in any position not otherwise specifically provided for for all as specified and as directed.
Taking down main switch/DB’s including MCB’s with board and fixture of any description and making good disturbed surface of walls etc complete all as specified and directed.
Taking down of Metal halide light and connected accessories and making good to the disturbed surface of walls etc complete all as specified and directed.
Taking down submain wiring any size complete and making good to the disturbed surfaces all as specified and as directed.
Taking out unserviceable LT cables from trenches/ducts/walls etc of any size all as specified and as directed. .
Supply and fix Sheet Metal enclosures with socket plug top and MCB, Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 10 KA, 240 volts complete all as specified and as directed.
Supply and fix Sheet Metal enclosures with socket plug top and MCB, Triple pole and earth enclosure with three pin and earth plug and socket complete with one triple pole MCB of 63 Amps, 10 KA, 415 volts complete all as specified and as directed.
Supply and fix distribution board (double door) , vertical, TPN 4 way, 415 Volts, IP 42 protection, with 200 Amp rated busbar, in sheet steel metal enclosure conforming to IS-13032, factory made and tested with copper bus bar, neutral links, cable lugs and earth bar, phosphatised and painted with epoxy polyster based powder paint, complete all as specified and as directed.
All as per item No 58 above but SPN 8 Way double door complete all as specified and directed.
Supply and fix Isolator TPN 415 volts, 63 Amps, 10 KA capacity, 'C' series ISI marked, in distribution board complete all as directed.
Supply and fix MCB, SPN, 240 volts, 40 Amps, 10 KA capacity 'C' series, ISI marked complete all as specified and as directed.
Supply and fix MCB, SP, 240 volts, 6-40 Amps, 10 KA capacity 'C' series, ISI marked complete all as specified and as directed.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed.
M & L earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including galvanised earth lead 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron including 15 mm bore GI pipe medium grade up to 7.5 metres long all as shown in electrical plate No. 3 of MES SSR part-I, and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast RCC slab 50mm thick in cement concrete (1:2:4)type B1 reinforced with welded steel wire fabricor XPM, (weight not less than 4kg/sqm) with cast iron frame, funnel with wire mesh , GI watering pipe of 20mm bore medium grade, lugs test point etc all as specified and as directed. Note : Quoted rate includes 7.5m length each of eath lead and 15mm bore GI protection pipe.
Material and labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/ 1100 volts grade confirming to IS 1536-1977 multi-stranded 6.0 Sqmm single core copper conductor drawn through rigid steel ERW conduit of 25 mm dia external and one run of 6.0 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked as earth continuity wire complete all as specified and directed. (Note: Two runs of conductor with one run of earth wire incl metallic shall be measured as one unit.)
M & L for point wiring complete with 1.5 sqmm single core multi stranded copper conductor FRLSH PVC insulated but unsheathed cable 1100 volts grade drawn throughand including rigid steel ERW conduit of 25mm dia (external) heavy duty including necessay flame proof /weather proof conduit accessories and fitting concealed in wall/ceiling etc including sealing threaded jointsin conduit accessories with teflon tape,flame proof sunken type pressed steel terminal boxes including 1.5 sqmm single core FRLSH PVC insulated but unsheathed multistranded copper conductor cable as in continuous earth.Wiring shall be suitable for flame proof area as per STEC-7 for the followings:
(a) One flame proof light point controlled by one,single pole flame proof switch
S & F Flame proof and weather proof rotary type switch,16 Amps,230 Volts,AC single pole, (LM-6) aluminium alloywith flame proof cable entry glands CMRS certified,ISI with termination box marked complete all as specified and directed .
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S & F flame proof and weather proof LED bulk head light fitting of 70W, IP66 protection of cost aluminium alloy material & heat and impact resistance toughen 'A' clear glass having Anti-corrosive expoxy powder coated finish complete with all accessories prewired including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing single pointed air termination aluminium rod, 12 mm dia, 300 mm long complete all as specified and directed.
Supply and fixing aluminium strip 25 mm X 3.15 mm complete with insulation along with saddles and fixing screws for roof conductors and down conductors above ground complete all as specified and directed.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including galvanised earth strip 25X4mm by means of bolts, nuts check nuts and washers of galvanised iron including 40 mm bore GI pipe medium grade up to 7.5 metres long all as shown in electrical plate No. 3 of MES SSR part-I, and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast RCC slab 50mm thick in cement concrete (1:2:4)type B1 reinforced with welded steel wire fabricor XPM, (weight not less than 4kg/sqm) with cast iron frame, funnel with wire mesh , GI watering pipe of 20mm bore medium grade, lugs test point etc. complete all as specified and directed. Note : quoted rates includes 7.5m length earth 0.7 earth lead and 40mm bore GI protection pipe.
S & F test point terminal block made of gunmetal or phospohorus bronze size 75 x75x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screws complete all as specified and directed.
Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 and making 30cm wide strips (total 5 Nos) with white and blue paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC complete all as specified and directed. Note:- Excavation & Pcc work will be meaured and paid separately under appropriate items.
PCC 1:4:8 Type D-2 using 40mm graded crushed stone aggregate as in pole bedding,complete all as specified & directed.
PCC 1:3:6 Type C-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete,complete all as specified & directed.
PCC 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in coping of poles and like incl watering,slightly rounded of chamfered angles and throating incl. necessary form work,complete all as specified.
S&F GI Pipe Light grade of 40mm bore complete with elbows, couplers etc and with MS Clamps, nuts, bolts, washers etc for fixing of pipe to wall/floor and laying in trenches for protection complete all as specified and as directed
Excavation trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable or pipes etc getting out in any type of strata & forming the sides and bottons surfaces to required level the side, surfaces to re complete all as specified and as directed
Excavation in trenches in exceeding 1.5m wide but exceeding 1.5m in depth for getting out in any type of strata complete all as specified and as directed by Engr/in/Charge.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Supply, laying and testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor as per IS 7098 Part-I, complete all as specified and directed of following sizes:-
(i) 120 Sqmm 3.5 Core
(ii) 95 Sqmm 3.5 Core
(iii) 35 Sqmm 3.5 core
(iv) 25 Sqmm 2.0 Core
(v) 4 Sqmm 2.0 Core
(vi) 16 Sqmm 4.0 Core
M & L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. (Note : Punned thickness only measured for payment)
Supplying and laying un-reinforced precast concrete cable cover class LV, type - 2, flat, size 300x180x40mm all as specified and directed.
Earthing complete with copper earth plate electrode 60 cm x60 cm x 3.15mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including Copper strip of 32X6mm by means of nut, bolts, check nuts and washers of copper/brass with 50mm bore GI protection pipe for earth lead as shown in electrical plate No.3 of SSR Part-I complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. Note : Quoted rates includes 7.5m length each of earth lead and protectoin pipe.
M&L for Out door type factory made Bus bar chamber of size 0.45x.75x 0.40M depth made out of CRCA sheet 3.15mm thick with 4 busbars of capacity 200 Amp internally prewired, suitable for MCCB 32 Amp 4 pole 451V, 16KA having locking arrangement, provn of suitable hole at bottom for incomming and out going UG cables complete incl painting with 2 coat of powder coated paint over a coat of red oxide primer on exterior and interior faces and bus bar insulator, errection of Bus Bar chamber with suitable qty of PCC 1:2:4, type B2 and supply, fixing and connection of MCCB incl earth work and provn of suitable frame at bottom made out of angle iron of size 40x40x6mm thick complete all as specified.
Taking down of old busbar chamber with connected items all as specified and directed.
M/s Pal Builders
Vijay Construction Co
KALIKAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .