Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC VILLAGE POST REGARI JOSHIMATH DISTT CHAMOLI 246483 UK | JOSHIMATH | CHAMOLI | UTTARAKHAND | 246483 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.8 L+₹14,001 (0.84%)Rejected-AOC JHABRERA ROAD NEAR POWER STATION MANGLOR DISTT HARIDWAR UTTRAKHAND | MANGLOR | HARIDWAR | UTTARAKHAND | L2 | Rejected-AOC Not L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Scanned copy of DD uploaded is used in other tender 8751/E8 Requested to submit fresh DD against tender cost but contractor fails to do so |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 871 EWS
GE 871 EWS PIN 913871 C/o 56 APO
REPAIR MAINT AND UPKEEP OF E M INSTALLATIONS AT JOSHIMATH AULI RUDRAPRAYAG NARENDRA NAGAR AND HARSIL UNDER GE 871 EWS
2023_MES_612904_1
8757/E8
Open Tender
Civil Works
Item Rate
180 days
Joshimath Auli Rudraprayag Narendra Nagar Harsil
as per NIT
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹40,000
Yes
3 Jan 2024
9 Aug 2023
18 Sept 2023
9 Aug 2023
11 Sept 2023
23 Aug 2023
Amount
Demolition of unreinforced cement concrete in ground floor and paving n.exc 15 cm thick (below or above ground level) etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Dismantling plain or corrugated steel sheeting, any gauge, thickness, incl Nainital or similar pattern roof covering all as directed.
Demolition of PCC block walling/brickwork or stone boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Taking down cement plaster on brick work or stone walls etc incl raking out joints hacking for key scrubbing down with water complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and directed..
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed..
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
Taking down chowkats or frames with shutters (with out taking of shutter from the frame) exc 1.5 sqm but n. exc 4sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (with out taking of shutter from the frame) n.exc 1.5 sqm each complete all as specified and directed.
M&L for Prepolished chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed and in need cement slurry in floor with grey cement and pigment and including over screed bed or bedding layer of mortar 20 mm thick laying floor finished in cement mortar 1:6 complete all as specified and directed.
M&L for PCC 75mm thick, 1:4:8 type D-2 40mm stone aggregate as in sub base of flooring complete all as specified and directed.
M&L for Hard Core (Broken stone /boulders) , broken to gauge n exc 63 mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and ramming to a true surfaces complete all as specified and directed.
M&L Cement concrete 1:2:4, type B-1(using 12.5mm graded stone aggregate) in flooring 75mm thick finished surface even and fair without using extra cement all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
S&F Plain, galvanised, mild steel sheeting 0.80mm, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl over screed bed or bedding layer of mortar 15mm thick for laying tiles in cement mortar 1:6 complete all as directed.
M&L for Glazed ceramic coloured tiles of size 300x450x7mm/350x450x7mm thick over and incl 10mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
M&L for providing 75mm thick cement concrete in 1:3:6 type C1, (using 20mm graded stone aggregate) finishing cement concrete surface even and fair without using extra cement as in plinth protection complete all as directed.
M&L for pre cast cement concrete solid block masonry 1:3:6 type C-1(using 20mm aggregate)with solid block exc 10cm in width setting in CM 1:6 etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces with CM 1:4 finished even and smooth without using extra cement in external surfaces complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces with CM 1:6 finished even and smooth without using extra cement in internal surfaces complete all as specified and directed.
M&L for preparing new plaster surface apply two coat of Cement based paint over one coat of alkali resistant primer complete all as specified and directed.
M&L for preparing old plaster surface apply two coat of Cement based paint complete all as specified and directed.
M&L for preparing new plaster surface apply three coats of white wash complete all as specified and directed.
M&L for preparing old plaster surface apply two coats of white wash complete all as specified and directed.
M&L preparation old steel surfaces and applying two coats of Synthetic enamel paint (Trusses/CGI Sheet as in roof) complete all as specified and directed.
M&L preparation of new steel surfaces with two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F rolled mild steel work in tubular section including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long dia of shank 5 to 10 mm complete all as specified and directed.
S&F mild steel work as in post and struts in fencing including cutting tops to shape as directed, drilling holes notching for wire, etc. flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire. Complete all as specified and directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolt including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed.
M&L MS round bars 10 mm dia over, cut to length, bent to shape required including crancking bending spirally for hoping for col hooking ends and binding with and including mile steel wire non less than 0.9 mm dia securing with clips confirming to Gd.I, IS- 432 (Part I) quality complete all as specified and directed.
S&F for 2nd class hard wood plain ,solid ,straight chowkats and frames ,wrought framed rebated on the solided rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F for 30mm thick flush shutter solid core construction with particle board core and plywood face panels, commercial type on both side complete all as specified and directed.
S&F for Steel windows with side hung shutters including projecting with box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F for powder coated aluminum section for making doors, windows, partition wall, shutters etc including styles & rails with standard anodized aluminum section, with one or more rebates including aluminium snap beading complete all as specified and directed (Glazing, rubber beading, hinges etc shall be measured and paid separately)
M&L for rubber beading for fixing glass panes in aluminium frame work complete all as specified and as directed.
S&F for 4.8 mm thick tinted sheet glass, fixed to aluminum frame work in panels n.exc 0.5 Sqm in each pane, complete all as specified and directed.
S&F for butt hinges medium weight cold rolled mild steel 100mm complete all as specified and directed.
S&F for mild steel butt hinges of 75mm long each complete all as specified and directed.
S&F for 200 mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150mm long anodised extruded aluminium alloy handles, fabricated type. complete all as specified and directed.
S&F for 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F for floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), fixed as in repair complete all as specified and directed.
S&F in repair for 0.56mm nominal dia wire galvanised mild steel wire cloth and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed.
M&L for preparation of old decorated wooden surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed.
M&L for point wiring in PVC casing & caping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly all as specified and directed for One light/fan point bell point controlled by one ,one way switch.
All as per item No 54 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 54 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 54 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 4 Sqmm for continuity earth wire connected to common earth dolly all as specified and directed.
S&F in replacement switch piano flush type 5/6 Amps single pole one way all as specified & directed.
S&F in replacement of switch piano flush type 15/16 Amps single pole one way all as specified & directed.
S& F in replacement socket out let 5 pin 5/6 Amps all as specified and directed.
S&F in replacement socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed.
S&F bell push, flush type 5 Amps white or ivory, ISI marked all as specified and directed.
S&F of call bell Ding Dong 230V, AC, single phase ISI marked all as specified and directed.
S&F in replacement of ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified & directed.
S&F in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.
S&F in replacement of 9 watt LED bulb cool day light, 230/240V, AC supply all as specified and directed.
S&F in replacement of LED light fitting two feet 1x10 watt, slim design, 230volts, including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S&F in replacement LED tube light fitting 4 ft, bright 18 watt slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed on bracket made out by GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed .
Taking down and refixing of LED tube light fitting bright 18 Watt. slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
M&L in replacement earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade ,wire mesh and lugs ,GI protection pipe of 15 mm bore light grade up to 7.5 mtr long ,etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
Supply and fix in replacement of DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed
Supply and fix in replacement of DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed.
Supply and fix in replacement of DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed .
Supply and fix in replacement MCB 6-40 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed .
Supply and fix in replacement MCB 32-40 amps, 10 KA, SPN 240 volt, 'C' series all as specified and directed
M&L in replacement of sub main wiring in PVC casing and caping of required size 2x6 sqmm PVC insulated multistrand copper conductor with 01x6 sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Make : Havells/ Plaza/ Polycab. Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 6 sqmm conductor with casing caping will be measured as one length.
Supply and fix in replacement of cable PVC insulated multi stranded Copper conductor 1100 volt grade heavy duty served with inner sheathing of PVC tape and over all PVC sheathed in service connection of size 2.5 sqmm 3 core all as specified and directed.
Supply and fix in replacement of Decorative LED 15 watt new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source and including connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
Supply and fixing LED Flood light 70 Watt 230V AC Outdoor type with thermal management in multiple optics and equipped with IP 66 protection , with impact and corrosion resistant complete with driver and lamp.
Supply and fix glow signage boards with base frame made from angle iron and backside form ACP sheet 3mm thick with IP 68 Protection LED module , good quality virgin monomer Acrylic sheet , MES Logo letter with 5 mm sun board channel , including complete wiring and power supply with IP 68 protection , each letter will be made with computer offset for having same letter style and type as approved by Engineer - in- charge , complete all as specified and directed. for following boards :-
(a) POWER HOUSE MAIN RECEIVING STATION (11/.440KV) CUM COMPLIANT CELL MILITARY ENGINEER SERVICES GARRISON ENGINEER 871 EWS
(b ) GARRISON ENGINEER 871 ENGINEER WORKS SECTION MILITARY ENGINEER SERVICES
(c) COMPLAINT CELL MILITARY ENGINEER SERVICES GARRISON ENGINEER 871 EWS
(e) WATER SUPPLY INSTALLATION MILITARY ENGINEER SERVICES GARRISON ENGINEER 871 EWS
M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M& L for spreading / filling loose stone aggregate of 40mm graded all as specified and directed by Engineer in Charge
M/S Swarn Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .