| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.9 LAccepted-AOC C O ABDUL GANI ISMAIL NALIYA KUTCH PIN 370655 GUJARAT | KACHCHH | GUJARAT | 370655 | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹16.2 L+₹82,344 (5.35%)Rejected-AOC T 1 GARDEN VIEW APARTMENT NEW BANKER COLONY MUNDRA ROAD BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L-2 | Rejected-AOC Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
26 Mar 2021, 6:00 pmClosed
GE (AF) Naliya NO 01
GE Air Force Stn Naliya
REPAIRS AND CLEANING OF SEWAGE LINE SEPTIC TANK SOAKAGE WELL PATH FENCING AND STEEL GATE AT AF STN MOTHALA
2021_MES_410742_3
8738/E8
Open Tender
Civil Works
Item Rate
330 days
Naliya
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF Naliya No.01
₹30,000
Yes
17 Dec 2021
12 Mar 2021
29 Mar 2021
12 Mar 2021
26 Mar 2021
12 Mar 2021
Amount
M&L for cleaning of blocked SWG/RCC drain pipes by rodding with rods/choke remover and making the continuous flow between two manholes or any locations as directed and well flushing with clean water after cleaning and removing of clogging/deposited mud etc including removing and refixing of manhole chamber cover of any description including sealing etc for 150 mm internal dia of pipe complete all as specified & as directed
All as per item No 1 above but for 100mm internal dia of pipe
Removing manhole cover of any type, size and thickness and of any description, cleaning manhole chamber of any shape/size upto 1.50 metre depth for removing sludge/mud from manhole by any means and refixing cover in same position /laid dry including sprinkling antibiotic powder complete all as specified & as directed
All as per item 03 above but exc. 1.50m and not exc. 2.50m depth.
M&L for cleaning of 50 users septic tank including debris/screen chambers by removing cover slab set in cement mortar of any shape/ thickness and pumping out water sludge mud with pump or manually including cleaning of inlet/outlet pipes, refixing cover slab in cement mortar (1:3), sprinkling of antibiotic powder etc complete all as specified & as directed.
All as per item No. 05 above but for 25 users capacity.
Cleaning and removing the blockage in floor trap, nahani, gully trap, WC, 'P' tarp and 'S' trap and refixing the same after cleaning the pipe, making good damage cement joint etc of pipe dia not exceeding 150 mm completed all as specified and as directed.
S&F in repair 110 mm dia bore PVC (SWR) Pipe, single socketed laid in treches/floors in any length with rubber ring joints complete all as specified & as directed
S&F in repair 110 mm dia bore PVC (SWR) Pipe, single soaketed laid in any length with rubber ring joints fixed in wall complete all as specified & as directed
S&F in repair PVC (SWR) bend,any radius for 110 mm bore pipe including jointing material compelete all as specified and as directed.
S&F in repair PVC (SWR) branch piece,single(single Y ) Equal or un equal for 110 mm bore Pipe including jointing material compelete all as specified and as directed.
S&F in repair PVC (SWR) branch double(Double Y) Equal or un equal for 110 mm bore Pipe including jointing material compelete all as specified and as directed.
S&F in repair PVC(SWR) Junction,Single(Single T ) equal or unequal for 110 mm bore pipe including jointing material compelete all as specified and as directed
S&F in repair 75 mm dia bore PVC (SWR) Pipe, single Socket laid in any length with rubber ring joints fixed in wall complete all as specified & as directed
S&F in repair PVC (SWR) bend,any radius for 75 mm bore pipe including jointing material complete all as specified & as directed
S&F in repair PVC (SWR) branch piece,single(single Y ) Equal or un equal for 75 mm bore Pipe including jointing material complete all as specified & as directed
S&F in repair PVC (SWR) branch piece,single(single T ) Equal or un equal for 75 mm bore Pipe including jointing material complete all as specified & as directed
S&F in repair PVC (SWR) vent cowl, equal or enqual for 110 mm bore complete all as specified & as directed
S&F in repairs Grating doom 100 dia of PTMT (Minimum weight 25 gm) complete all as specified & as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises/md land complete all as directed.
M&L for non skid coloured ceramic tiles, 7 to 8mm thick,(Square /rectangular) area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm in floors etc.,laid over 15mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for non skid coloured ceramic tiles, 7 to 8mm thick,(Square /rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm in floors etc., laid over 15mm thick screed bed in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for dark shade vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 Sqm in floors etc. laid over 15mm thick screed bed in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for coloured glazed ceramic tiles, 300 x 200 x 7mm thick, glossy finish, conforming to Group B-III of IS-13712, first quality, of approved colour, over backing coat of 10mm thick in CM 1:4, laid on vertical surfaces such as skirting or dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
Demolition of reinforced cement concrete (reinforced cut to required to facilitate demolition) in any description and in any position not otherwise specifically provided for including removing debris outside of Md land complete all as directed.
M&L pre-cast reinforced cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate for manhole covers including placing the cover in position and set in cement mortar (1:4) complete all as specified and directed. Note: Reinforcement shall be measured and paid seperately.
M&L for 10mm dia and over TMT steel reiforcement bars for precast manhole cover cut to length bent to shape required and binding with MS wire annealed not less than 0.9mm dia, complete all as specified and directed.
Excavation in trenches not exc.1.50m wide and not exc 1.5m deep for sewage pipe line and manhole not exc. 10sqm on plan and getting out in soft/loose soil complete all as specified & directed.
Returning filling in soft/loose soil including spreading, leveling, watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
Removing excavated material exc 1.5Km but n.exc 5Km and deposited where directed.
Demolition and breaking up old drain pipe (SWG, AC or reinforced) set in cement mortar including haunching and bed concrete for 150mm dia & removing debris outside of MD land complete all as specified.
M&L for 150 mm bore SGSW drain pipe, of grade 'A' laid in trenches and jointed in CM (1:1) including testing etc including demolition and breaking up old drain pipe (SWG, AC or reinforced) set in cement mortar including haunching and bed concrete for 150mm dia & removing debris outside of MD land complete all as specified and directed,
M&L for concrete bed to 150mm dia drain pipes including packing under and haunching aganst the sides of pipe in PCC (1:3:6), type C2, using 40 mm graded stone aggregate after they are laid and tested complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as directed.
M&L Cement concrete type D2 1 :4:8 ( using 40mm graded stone aggregates) as in foundations and mass concrete complete all as specified and directed.
M&L for precast cement concrete block masonry walling with solid blocks of PCC (1:5:8) using 20mm graded stone aggregates, exc 10cm in width and sett in cement plaster (1:4) including demolition of precast block masonry walling, built in cement mortar in any position and height and removing debris out side of MD land complete all as specified and as directed.
M&L Cement concrete type C1 1 :3:6 ( using 20mm graded stone aggregates) as in copings and benching/haunching and foundation filling mass concrete complete all as specified and directed.
M&L two coats of White wash on new plaster surface of wall incl preparation over rendering 10mm thick on fair face of concrete/ block masonry in cement mortar (1:6) on finishing surface even and smooth without using extra cement including taking down cement plaster on brick or stone walls, etc. Including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Cutting into existing manholes, for insertion of 150mm dia of pipe for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching all as directed and specified.
Dismantling posts or struts (Wood,steel or RCC) any sectionembedded in natural ground including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Ditto all as per Item No. 40 here-in-before in but embedded in concrete including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling of fencing wire mesh of any type
Excavation in post holes each n.exc 0.5cum getting out ,returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm watering complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc.
M&L for providing precast cement concrete 1:2:4 type B1, using 20 mm graded stone aggregates as in copings,bed plates,brackets etc with plain fair faces,including necessary formwork chamfers, weatherings,throating or slightly rounded and setting in cement mortar 1:6 all as specified and directed.
Supply only Chain link MS galvanised fencing any size or type Mesh Size 50X50mm.
Fixing only Chain link fencing including line wires,any mesh, size and type to any standards,rails straining bolts, etc. including provision of binding wire complete all as specified and directed.
S&F in repairs galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. all as specified and as directed. (Note:Each line wire shall be measured)
S&F MS screw bolts machine made of shank 11 to 15mm screwed both ends length of bolt exc 10cm and not exc 15cm long including fixing to RCC fencing posts with chain link fencing complete all as specified and as directed.
S&F mild steel round bars 10mm dia ,and over cut to length, bent to shape required including crancking bending, spirally for hopping for columns etc hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates,rail,braces,etc complete,drilled for fixing of rails to door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings exclusive of steel sheeting or other covering running rails and guides) and hanging;also fastening and fixing complete all as specified and as directed.
S&F Stairs (framed) including stringers, treades, landing,ladders with railling, balusters, hand rails etc. Including cleats, brackets, etc. complete
M&L in repairs, machine pressed precast concrete, rubber moulded, interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade over sand filling under floors as in sand cushioning 50 mm thick over 75mm thick PCC 1:4:8 type D2 by using 40mm graded stone aggregate complete all as specified and directed.
S&F Hand rails, half round or other steel section or core for wooden hand rail straight portion nosing to steps including embedding in concrete and screwing etc. wind tie for roof including securing bolts, post and struts in fencing in cutting tops to shape as directed , drilling holes , notching for wire, etc. flat iron fillets( for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified.
S&F Roof trusses (Framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing( Beam, tee, angle, channel or flat section including distance pieces, cleats etc conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L preparation of new steel surfaces of any description not otherwise described width or girth exc. 10 cm, applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair 20mm dia GI tubing medium grade, with all fitting and fixed to walls and ceiling or laid in floors.
S&F in repair 20mm dia UPVC Pipes of pressure rating 10 kgf/CM with all fitting and fixed to walls and ceiling or laid in floors.
S&F in repair 15mm dia GI tubing medium grade, with all fitting and fixed to walls and ceiling or laid in floors.
S&F in repair 15 mm dia UPVC Pipes of pressure rating 10 kgf/CM with all fitting and fixed to walls and ceiling or laid in floors.
S&F in repairs 15 mm dia bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe in repair.
S&F in repairs 15 mm dia pillar taps with capstan heads, chromium plated, screwed down, screwed for iron pipe in repair.
S&F in repairs 15 mm dia stop valves, cast copper alloy, screwed down,high pressure with crutch or butterfly handle, screwed for iron pipe in repair.
S&F in repairs gun metal globe or gate valves 20mm dia with iron wheel head screwed both ends for iron pipe and fixed
S&F in repairs PVC low level flushing cistern 10 Ltrs capacity including float valve, inlet, outlet, connection to flush pipe , PVC connection etc complete, ISI mark and approved make, including testing complete all as specified and directed
S&F in repair internal syphonic action type assembly with handle complete for 10 ltrs capacity, PVC valveless syphonic action type low level flushing cistern and connection to pipe or lever etc. complete all as specified and as directed .
S&F PVC water closet seat cover, black or white, closed pattern, with flat bottom and cover and mild steel chromium plated or aluminised hinging device, including taking down and removal of existing old all as specified and directed
M& PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor topping, 40mm thick, surfaces finished even and smooth with using extra cement complete all as specified.
M& L for 75 mm thick PCC 1:2:4 type B1 (using 40 mm graded stone aggregate) in floorings including finishing the surface even and smooth using extra cement, laying the top concrete floor complete all as specified and directed.
M& L for 75 mm thick PCC 1:3:6 type C2(using 40 mm graded stone aggregate) in plinth including finishing the surface even and smooth laying the top concrete floor complete all as specified and directed.
Supply only 38mmx3mm glass dividing strips as in floors complete all as specified.
Forming Contraction (Dummy)joints 65mm deep x 10mm wide, filled with sealing compound Grade'B' all as specified and directed.
M& L for finishing surface of concrete floors in pavements etc with brooming impressions all as specified and directed.
Cleaning and removing of all scales and dirt etc. from PVC water tanks of 250 ltrs but upto 500 ltrs Capacity and from mouth of the circulating pipes of any dia etc. repairs to minor cracks repairs, stopping leaking and inlet/outlet with approved sealent, disinfacting the tank surfaces by suitable methods, including writing with paint cleaning date on tank complete all as specified & directed.
-Ditto- as per Item No 74 above but of 500 ltrs but upto 1000 ltrs capacity
S & F in repair 500 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling & disconnecting complete all as specified & as directed.
S & F in repair 1000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling & disconnecting complete all as specified & as directed.
S&F in repairs rotational moulded polyethylene water storage tanks lid with clips, screws, loking device compelete for 500 litres/ 1000 litres tanks capacity complete all as specified and as directed.
S&F fixed in repairs 20mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Venus Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .