Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.6 LAccepted-AOC C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L-1 | Accepted-AOC AOC | |
| 2 | L-2₹21.0 L+₹1.0 L (5.10%)Rejected-AOC NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L-2 | Rejected-AOC Rejected | |
| 3 | L-3₹21.4 L+₹1.4 L (7.23%)Rejected-AOC 164 HIRANI NAGAR OPP SIDDHI VINAYAK TEMPLE MADHAPAR KUTCH 370 020 | KACHCHH | GUJARAT | 370020 | L-3 | Rejected-AOC Rejected | |
| 4 | L-4₹21.4 L+₹1.5 L (7.41%)Rejected-AOC | L-4 | Rejected-AOC Rejected | |
| 5 | L-5₹23.4 L+₹3.5 L (17.3%)Rejected-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L-5 | Rejected-AOC Rejected |
Tender Value
₹19.6 L
EMD Value
₹39,200
Closing Date
11 Jan 2022, 6:00 pmClosed
GE (AF) NALIYA No 1
GE Air Force Station Naliya No 01
COMPREHENSIVE MAINTENANCE AND REPAIRS TO CENTRAL AC PLANT AND MISC CONNECTED ITEMS INSTALLED AT 2403 C FLT AT AF STN NALIYA
2021_MES_496093_1
8799/E8
Open Tender
Civil Works
Item Rate
330 days
Naliya
As Per NIT
7 documents required · 7 mandatory
₹500
Yes
GE (AF) NALIYA No 1
₹39,200
Yes
7 Mar 2022
20 Dec 2021
13 Jan 2022
20 Dec 2021
11 Jan 2022
4 Jan 2022
20 Dec 2021 - 27 Dec 2021
Amount
Supply & Fix in replacement Display controller of 45 KW capacity Hot Water generator of Make- Rapid Cool all as directed by EIC.
Supply & Fix in replacement Air release valve complete assy suitable for 45 KW capacity Hot Water generator of Make- Rapid Cool all as directed by EIC.
Supply and fix Power contactor in repairs for starter of 3 Pole 440 Volts operating coil voltage 110/230/415 Volts Siemens 3TS51 model for AC plant.Make- SEIMENS or equivalent
Supply and fix in repairs V-belts type A-23 model suitable for CSU motors for AC plant Make; Fenner/ Dunlop or equivalent
Supply and fix in repairs V-belts type B-62 model suitable for AHU motors for AC plant Make; Fenner/ Dunlop or equivalent
Supply and fix in repairs V-belts type A-44 model suitable for AHU motors for AC plant Make; Fenner/ Dunlop or equivalent
S& f In repairs Air Break power contactors of Chiller Plant control Panel of Rated current AC3 upto 415V 250 amps capacity of auxillary contacts 2NO+2NC contacts with coil voltage 230 Volts 50 HZ (LPs for 110,230,415V) of model 3TF54 02-AP0 of Make-SIEMENS or equivalent in CG/ABB/Havells/L&T complete all as specified and directed .
M&L for top up/ gas charging with refrigerant gas (R-407C) for Package / Chiller Unit of capacity 22/32/37/39 TR after vacuuming and leak testing including bracing suction/ discharge line and testing complete all as specified and as directed.
M&L for repair / replacement of GI Base Frame Channel/Angle type of size 20x25x6 mm of CSU (Size-1.5mtrx1mtr Approx) and 1mm GI sheet frame of size approx 2.5 Sqm (inside of Ceiling suspended unit 3 TR capacity) for holding the FRP/PVC air filter including black enamel paint with one coat primer all as directed by EIC
M & L for Servicing, greasing and alignment of AHU/CSU motors and pullies installed at AF Stn Naliya all as directed by EIC
Supply & Fix sensor of Humidity and temp at TP-III all as directed Make-Honey well operating on DC volts all as per existing Make and model.
Repairs , servicing , cleaning and descaling with the help of diluted Acid of heat exchanger for hot water & cold water installed in CSU (Ceiling suspended unit) of 3TR capacity including minor repair and parts as nut bolt brazing/welding etc for any leakage observed all as directed by EIC
S & F in replacement 125 Amps, 16 kA, MCCB 4 pole, 415 Volts, with adjustable thermal and fixed magnetic relay, as per existing make to accommodate in electric LT Panel with all necessary connections complete.
All as per Ser item No 13.00 here-in-before but of 100 Amps, 16 kA
All as per Ser item No 13.00 here-in-before but of 63 Amps, 16 kA
Repair / servicing of Hot Water Generator 45KW capacity 3 pase 440 Volts 50Hz including minor parts as two qty heating coil /nut bolt/packing etc all as directed by EIC.
S & F in repair to CSU monoblock pump set of capacity 0.25 HP, single phase 230 Volts all as directed by EIC. Make Crompton/Kriloskar/ABB
S & F in replacement of inlet Hot water valve control actuators installed out side CSU of model No: VC6013ZZ00 including testing and commisioning all as directed by EIC.Make-Honeywel/ZOLOTO or equivalent
Supply & Fix in replacement of 12V 26 AH maintenance free batteries of (Make Exide/Amtrex/Amaron) (Model: 12AL026 Make Amaron) for power backup of UPS unit all as directed by EIC
S & F in replacement of inlet chilled water valve control actuators installed out side CSU of model No: CN7510A2001 including testing and commisioning all as directed by EIC.Make-Honeywell
Supply & Fix in replacement of 12V 7 AH maintenance free (SMF) batteries of (Make AMARON/Exide/Amtrex) for power backup of UPS unit all as directed by EIC
S & F in replacement of inlet chilled water three way valve of size 40/50 mm installed out side CSU of including testing and commisioning all as directed by EIC.
S & F in replacement of inlet Hot water three way valve 40/50mm size installed out side CSU including testing and commisioning all as directed by EIC.
Supply & Fix in replacement of Spun Filter /Cartridge of RO Plant all as directed by Eng in charge.
M&L for Anti scalant suitable for preventing formation of calcium carbonate and calcium sulphate and fouling by silica complete all as specified and as directed.
Supply & Fix in replacement of Membrane of RO Plant of size 40/40 all as directed by EIC. (Each 4/Plant=8 Each ) Make-Filmtec or equivalent
Supply & Fix in replacement of soft sand from Sand filter for RO plant all as directedby EIC.
Supply & Fix in replacement of Activated Carbon from carbon filter for RO plant all as directed by EIC.
Dismantling the components of Reverse Osmosis plant and checking the serviceability of plant including rubber bushes, fittings, low pressure/ high pressure motor pumps & Cleaning of membrane filter with citric acid and cleaning, washing with the help of high pressure water pump complete and re-fixing the same after necessary repairs and replacement of unserviceable parts, commissioning and testing complete all as specified and as directed. Notes:- Replacement of defective items of existing make/ size shall be measured and paid separately under respective items.
Repair / rewinding including commisioning and transportation of high pressure pump of capacity 3 HP suitable for 1000 LPH capacity RO Plant all as directed by EIC.
Maintenance / repair to AUH blower motor (FLAME PROOF ENCLOSURE) of capacity 10 HP / 7.5KW Suitable for 35 TR, three phase 440 Volts with rewinding of AHU motors with suitable size of super enamelled copper wire as per exisiting including shaft bearing including transportation to maintenance work shop all as directed by EIC.Make-CG
Maintenance / repair to AUH blower motor (FLAME PROOF ENCLOSURE) of capacity 7.33 HP / 5.5 KW Suitable for 25 TR, three phase 440 Volts with rewinding of AHU motors with suitable size of super enamelled copper wire as per exisiting including shaft bearing including transportation to maintenance work shop all as directed by EIC.Make -CG
Maintenance / repair to CSU blower motor of capacity 1.5 HP, three phase 440 Volts with winding of CSU blower motors with suitable size of super enamelled copper wire as per exisiting including shaft bearing including transportation to maintenance work shop all as directed by EIC. Make-CG
Supply & Fix onload fuse unit switch of 415 Volt, 50 Hz, TP of capacity 400 Amps with breaking capacity 120 KA for 150 TR chiller Plant all as directed by EIC.Make-Seimens or equivalent
Cutting of worn out aluminium cable terminal lugs from the LT cable of size 120 Sqmm -400 Sqmm 3.5 core, crimping of new aluminium cable lugs and fixing with LT Panel terminal studs including cutting/dressing of cable, excavation in any type of soil refilling the trench including sand cushioning and brick protection as directed and specified etc complete all as specified and directed.
M & L for descaling of condensor coil with non acidic base solution of 13x3 TR Chiller Plant water cooled type including all T & P all as directed by EIC.
S&F in replacement of EWT (Entering water temperature) of 13x3 or 12x3 TR chiller Plant sensor as per existing model complete all as specified and as directed.
S&F in replacement LWT(Leaving water Temperature) of 13x3 or 12x3 TR chiller Plantsensor as per existing model complete all as specified and as directed.
Removing of old damaged viscus Pre air filter from AHU and S&F new Pre air filter capable of filtering 10 microns with 90% efficiency and above particle size on return air for AHU unit of 35/25 TR AHU complete all as specified and as directed.Model No.EU4/G4 Make:-Thermadyne Pvt.LTd. of Size:-305x610x50mm
Removing of old damaged Bag air filter from AHU and S&F new Pre air filter capable of filtering 05 microns with 99% efficiency and above particle size on return air for AHU unit of 35/25 TR AHU complete all as specified and as directed.Model No.G3/G4/F5/F6/F7/F8/F9/MERV-14 Make:-Thermadyne Pvt.LTd. of Size:-305x610x305mm
M&L for removing of damaged portion of duct insulation and fixing new Nitrile Insulation 13 mm (minium) thick closed cell elastomeric nitrile rubber insulation of 40-60 kg/cum density, on duct surface free from dust etc using a thin film of insulation material all as per manufacturer's recommended adhesive. Both duct and instulation, keeping the insulation material under compression (without any stretching), seal all joints air tight etc complete all as specified and as directed. Make:- Aramacell/ A Flex/ Armaflex/ K Flex as approved by GE.
S&F in repairs expansion valve suitable for (12/13X3) 36/39 Ton capacity AC units (Bluestar) as per existing make and model including cutting, brazing/ welding, leak testing etc complete all as specified and as directed.
S&F in replacement 80/100 mm dia butterfly valve of AC chillier plant circulation pipe line, of existing model, welding the same as per existing fixing arrangements complete all as specified and as directed.
Supply Installation testing & commissioning of display controller with PCB card for water cooled chiller Capacity-37/39TR all as directed by EIC
Supply Installation testing & commissioning of Humidifier controller for atuomation all as directed by EIC
Supply Installation testing & commissioning of Heater strip 2/4KW capacity all as directed
Supply of Thermostate for humidifier all as directed by EIC
Supply & Fix in replacement of new compressor sealed unit sutiable for unit dismantled in this work, as per existing make and model, including brazing / welding of suction and discharge line, including first filling gas and leak testing complete and liquid line air dryer, 12.0/13.00 Ton capacity suitable for 37 TR chiller AC unit complete all as specified and as directed. Make:- Danfoss Model No:-SZ185S4RC or equivalent to Tacumsha/ Blue star/ Copeland as approved by GE.
S & F in replacement of 40 TR capacity Cooling Tower PVC filings along with sprinkler set, tension bar GI material,turn buckle, branch pipe of suitable size(approx 50 mm dia) and FRP eliminator blades for each cooling tower all as directed by EIC.
Supply & Fix in repair to cooling tower blower induction motor of capacity 5 HP/3.7KW, three phase 440 Volts with as per exisiting including shaft bearing all as directed by EIC. Make-Kirloskar, Type-KDI-527++.
Repair to hot water pipe line of dia 40 /50 mm glasswool insulation with Aluminium cladding all as directed by EIC.
Repair to cold water line of dia 40/50 mm glass wool insulation with Aluminium cladding all as directed by EIC..
S&F power contactor 3 pase system for 1.5 HP motor installed at TP-III of Model No-MNXA1 & MXA1 Make-L&T or equivalent including 10 Amps relay & PLA relay of blower motor Motor all as directed by EIC.
S&F power contactor for single phase motor of capacity 0.25 HP installed at TP-III of Model No-LAEN22 Make-Schnieder or equivalent including all as directed by EIC.
M&L for opening of CSU(Ceiling suspended unit) and taking down cover plate, disconnecting electric connections, opening the blower motor, blower, belt, shaft and bearings (02Nos) for repair and refixing complete assembly with new shaft and bearings (02 Nos) for 3 TR Capacity CSU including testing and greasing complete all as specified and as directed.
M&L for opening of AHU(Air Handling unit) and taking down cover plate, disconnecting electric connections, opening the blower motor, blower, belt, shaft and bearings (02Nos) for repair and refixing complete assembly with new ball bearings (02 Nos) for 25 TR Capacity AHU including testing and greasing complete all as specified and as directed.
M&L for opening of AHU(Air Handling unit) and taking down cover plate, disconnecting electric connections, opening the blower motor, blower, belt, shaft and bearings (02 Nos) for repair and refixing complete assembly with new ball bearings (02 Nos) for 35 TR Capacity AHU including testing and greasing complete all as specified and as directed.
M & L for FRP coating inside CSU area for arresting any type of water leakage in side CSU all as directed by EIC.
S & F in replacement of cooling tower water inlet float Float valve PVC type all as directed by EIC.
S & F metal based Float valve for Humidifier of capacity 2KW to 4 KW all as directed by EIC.
S & F Cooling Tower Fan blade suitable for 40 TR capacity cooling tower all as directed by EIC.
Anil Builders
Pelectricals
Jyoti Refrigeration
M/s Bombay Novelty Stores
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .