Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹36.1 L+₹1.2 L (3.47%)Rejected-Finance 164 HIRANI NAGAR OPP SIDDHI VINAYAK TEMPLE MADHAPAR KUTCH 370 020 | KACHCHH | GUJARAT | 370020 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹37.2 L+₹2.3 L (6.73%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹39.5 L+₹4.6 L (13.0%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹40.0 L+₹5.1 L (14.5%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
7 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
REPAIR/REPLACEMENT OF HT OVERHEAD LINES WITH UG CABLES AND IMPROVEMENT OF E/M INSTALLATION AT DOMESTIC AND TECHNICAL AREA AT AF STATION BHUJ
2023_MES_585196_1
84210/E8
Open Tender
Civil Works
Item Rate
180 days
BHUJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) BHUJ
₹84,000
Yes
27 Apr 2023
10 Mar 2023
10 Apr 2023
10 Mar 2023
7 Apr 2023
24 Mar 2023
Amount
Dismantling and taking down old unserviceable Aluminium Conductor Steel Reinforced (ACSR) of any size including aluminium binding wire from overhead lines on LT poles all as directed. Note: (i) Weight of old conductors shall be determined by measuring the horizontal distance between centres of two adjacent poles and compounding the weight of conductor of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (ii) Weight of the old conductors shall be calculated from the nominal weights given in tables in the relevant IS code.
Dismantling HT insulators any type, any size all as directed by Engineer-in-Charge
Dismantling earth wire or copper conductor, service feeder or distributor span
Dismantling HT concrete poles/ struts, any size
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as directed by Engineer-in-Charge
Dismantling stay assembly complete.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft /loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and as directed
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and as directed
M & L for providing dry river sand as in cushioning to UG cables including gently punning down of sand in layers all as directed and specified. Note : For measurement purpose punned thickness shall be considered.
M & L for unreinforced precast concrete cable covers CLASS HV type I, flat size 300 x 180 x 40 mm laid transverse to cable all as directed and specified.
M & L for unreinforced precast concrete cable covers CLASS LV type 2, flat size 300 x 180 x 40 mm laid transverse to cable all as directed and specified.
S&F 100 mm bore GI tubing, light grade, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS clamps with necessary bolts, nuts and washers all as specified and directed.
All as per item No.13 above but 50mm bore GI tubing
Taking out unserviceable HT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc, for the sizes of cables 120 Sqmm all as directed by Engr- in -charge.
Supply, laying, testing and commissioning of serviceable HT 11 KV 3 core 120 sqmm of size cable in trenches/fixed to poles/wall, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables( HT ), heavy duty with aluminium conductor, 11000 volts (earthed) grade all as specified and directed by EIC. Note: Excavation, earthwork, cable joints, sand coushing & cable cover will be measured and paid separately if required.
M & L for erection of Precast HT cable route / cable path indicator,made out of PCC 1:2:4 ,type Bo,12.5 mm graded stone aggregates of size 100 Cm (Height) x 12 Cm (Width) x 8 Cm (Thichness), painted with orange colour lettering synthetic paint and letters 4 inch "HT 11 KV CABLE" to be written with black colour lettering synthetic paint and embedded in PCC block 1:3:6 type C2 (using 40mm graded aggregate) of size 15cm x 15cm x 20cm including necessary excavation for PCC block c, placed at interval of every 30 M ,complete all as specified and as directed by Engr-in-Charge.
M & L for erection of Precast LT cable route / cable path indicator,made out of PCC 1:2:4 ,type Bo,12.5 mm graded stone aggregates of size 100 Cm (Height) x 12 Cm (Width) x 8 Cm (Thichness), painted with orange colour lettering synthetic paint and letters 4 inch "LT CABLE" to be written with black colour lettering synthetic paint and embedded in PCC block 1:3:6 type C2 (using 40mm graded aggregate) of size 15cm x 15cm x 20cm including necessary excavation for PCC block c, placed at interval of every 30 M ,complete all as specified and as directed by Engr-in-Charge.
Supply, fixing, testing and commisioning of factory made HT out door distribution panel Single door of size 1000x1000x600 mm including locking arrengment cubical type dust proof , weather proof , vermin proof asthetically designed, having atleast IP -54 degree of ingress protection , fabricated from 3 mm thick CRCA sheet with front & rear opening including bus bar chamber , continuous GI strip earth bus bar , 3 strips of copper bus bar of 400 Amps capacity, insulated color sleaves, procelain/epoxy insulators, rail channels cable alloy, danger notice board (11000 Volt) including made out of 14 guage MS sheet over angle iron frame of size 50x50x6mm , 60 cm grouted in ground floor and 60 cm above GL including necessary excavation ,foundation .PCC and taking down old panel complete all as specified and directed.
Supply, fixing, testing and commisioning in replacement Outdoor LT Feeder distribution panel (CPRI Approved) LT electrical distribution panel board floor mounted cubicle type suitable for one incoming MCCB and two outgoing MCCB, one multifunction LED Meter dust proof weather proof vermin proof asthetically designed having at least IP-54 degree of ingress protection fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber continuous GI strip earth bus bar 4 strip of Aluminium bus bar 250 amp capacity insulated colour sleeves precilin/ epoxy insulator rai channel cable alloy danger notice board including made out of 14 gauge CRCA Sheet over angle iron frame of size 40x40x6 mm, 30 cm grouted in groung floor and 30 cm above GL including connection with suitable copper cable FRLSH PVC single core complete all as specified and directed.
S & F in repair Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size up to 120 Sqmm 3 core all as directed.
S & F in repair of outdoor type heat shrinkable cable end joint for 3 core, up to 120 Sqmm HT, 11 KV (earth), XLPE insulated heavy duty aluminium conductor cable including making incoming and outgoing electrical connections all as directed.
S & F LED flood light 100 Watt, IP-66 protection in replacement of metal halide lights, flood light-with High Lumen output fitting with exclusive innivative designed, long life versatile pressure die cast aluminium body and luminaire with high power LED as light source complete suitable for highlightening architectural fixed with suitable GI clamps having two coat of enamal paint, nut bolts all as specified and as directed by Engineer-in-charge.
S & F of 60 watt in replacement LED street/ security light luminaries comprising of cast aluminium housing, toughned glass, IP 65/66 and wired with all accessories enclosed with glass cover in frame including suitable size of street light bracket complete all as specified and directed.
S & F in repair, connecting, testing and commissioning and jointing, LT under ground cable of size 25sqmm, 4 core, 1100 volts grade, XLPE insulated, armoured with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in trenches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts or encased in GI pipe complete all as specified and as directed by the Engineer-in-Charge. Note:- Sand cushioning, Cable protection cover, GI pipes, excavation and earth work shall be measured and paid for separately under respective items of Schedule "A" .
All as per item No.26 above but for size of LT cable 16 sqmm. 2 core
M&L for earthing complete with copper earth plate electrode of size 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including copper strip of 32 x 6 mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of HDPE protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete. Note: GI strip exceeding 7.5m long shall be measured & paid seperately.
S&F GI strip 32X6 mm with saddles and fixing screws etc for jointing with transformer and lightening arresters with the earth pit strip etc all as directed by engineer-in-charge complete.
M&L for Locating of fault in HT 11 KV cable of any size laid in trenches by heiring of electronic fault locating machine for finding out the fault of defective 11 KV HT cable at different locations including excavation of trenches for each fault at site making sufficient space for working inside the trenches for jointing the cable and further excavation and refilling after connection and testing of straight through joint as per requirement complete all as specified and directed. Note :- (i)The fault located equipment will be brought at site within 02 days of Instruction received from Engineer-in-charge complete all as specified and as directed by Engineer-in-charge.
M& L for spreading, well ramming in layers using 40mm graded coarse aggregate over inside the sub stn area complete all as directed by Engr-in-Charge.
M&L for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes incl painting over primer to cover cable ducts in sub stations.
M & L for scraping of old painted surfaces of two pole structure including all nuts bolts, GOD/DO, channel, cross arm & street light brackets etc., and preparing the surface and painting with a coat of silver colour aluminium paint all as directed by Engineer-in-Charge.
M & L for scraping of old painted surfaces of four pole structure including all nuts bolts, GOD/DO, channel, cross arm & street light brackets etc., and preparing the surface and painting with a coat of silver colour aluminium paint all as directed by Engineer-in-Charge.
S & F in repair existing make, size and type of street light digital timer complete all as specified and directed by Engineer-in-Charge.
S & F in repair of LED Post top of 25 Watt Integral pole mounted decorative LED with IP-65 protection complete fixed on existing post, all as specified and directed by Engineer-in-Charge.
S & F in repair of MCCB, 415 Volts, 3 pole with fix / adjustable type having 25 to 100 Amps with breaking capacity 16 KA all as specified and as directed.
All as per item No.37 above but fix type, 160 Amps with breaking capacity 36 KA
All as per item No.37 above but 200Amps with breaking capacity 36 KA
All as per item No.37 above but 250Amps with breaking capacity 36 KA
Pelectricals
SHOBHIT BUILDERS
Anil Builders
Abhishek Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .