Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
2 Dec 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
MAINTENANC
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer shall possess a valid Electrical Contractor License, issued by any State Government or Union Territory Administration, authorizing execution of electrical works up to 650 V. The contractor shall have in his employment or shall engage a person holding a valid certificate of competency issued by any State Government or Union Territory Administration for supervision of electrical works up to 650 V.Offers not accompanied by a valid Electrical Contractor License and requisite Supervisor competency for works up to 650 V shall be summarily rejected.
Similar Nature of Work: Supply, installation, testing and commissioning of LT/HT electrical GS assets ORSupply, installation, testing and commissioning of electrification or rewiring of building/workshop. ORSupply, installation, testing and commissioning of Yard/circulating area/street lighting/tunnel/facade lighting. ORSupply, installation, testing and commissioning of high-mast lighting. ORSupply, installation, testing and commissioning of glow signages. ORSupply, installation, testing and commissioning of LT/HT electrical GS sub-station with at least 50% capacity of proposed sub-station ORRepair/overhauling of LT/HT electrical GS assets including LT/HT sub-stations.
49 conditions · 8 needing a document upload
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) /Limited Liability Partnership (LLP) etc., and corresponding documents shall be submitted by the tenderer as per the composition of the Firm.
The Bid Security shall be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA of GCC and shall be valid for a period of 90 days beyond thebid validity period. Non-submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non- submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days of deadline of submission of bids.
Eligibility criteria: Eligibility criteria shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
Tender Form (First sheet, Second sheet) of The GCC April 2022.
Certificate format (Affidavit) which available as Annexure - V in Mandatory documents. A facility has already created for online submission of Annexure V of GCC in IREPS module; uploading of physically signed Annexure V by tenderer has been discontinued
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) /Limited Liability Partnership (LLP) etc.
The corresponding documents shall be submitted by the tenderer as per the composition of the Firm: Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) above. HUF: (i) A copy of a notarized affidavit on Stamp Paper declaring that he who is submitting the tender onbehalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above. Partnership Firm: (i) All documents as mentionedin para18 of the Tender Form (Second Sheet). Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company(backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above. LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders/contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were/are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para10 of the Tender Form (Second Sheet). Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents andcreate liability against the Society/Trust.(iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as per Clause No.5 of PART -1 of The GCC, April 2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Guntakal Division: 1. Provision of Electrical Arrangements for the Construction of Parcel Offices at Anantapur, Dhone and Dharmavaram Stations.2. Provision of Earthing Arrangements to All the Electrical Assets, Duly Improving/Replacing the Existing Earth Pits Over Division.
GTL-EM-64-2026-27~SCOR
GTL-EM-64-2026-27
Open
Works - General
9 Months
Anantapur, Andhra Pradesh
₹0
₹4.5 L
10 Nov 2026
10 Nov 2026
18 Nov 2026
148 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,32,74,287.53 | ||
| details. | Breakup for | — | — | ||
| Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required Sl No.1.14 of DSR 2025 | — | — | — | 17,18,000 | |
| details. | Breakup for | — | — | ||
| Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (SL No:1.21 of DSR-2025) | — | — | — | 4,60,690 | |
| details. | Breakup for | — | — | ||
| Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (SL No:1.24 of DSR- 2025) | — | — | — | 80,240 | |
| details. | Breakup for | — | — | ||
| Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (SL No:1.27 of DSR-2025) | — | — | — | 62,280 | |
| details. | Breakup for | — | — | ||
| Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (SL No:1.3 of DSR-2025) | — | — | — | 10,10,400 | |
| — | 9.00 | — | — | ||
| Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. (SL No:1.38 of DSR-2025) | — | — | — | 1,008 | |
| — | 9.00 | — | — | ||
| Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (SL No:1.57 of DSR-2025) | — | — | — | 7,263 | |
| — | 50.00 | — | — | ||
| Supplying and fixing PVC batten/ angle holder including connections etc. as required. (SL No:1.58 of DSR-2025) | — | — | — | 6,600 | |
| details. | Breakup for | — | — | ||
| Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. (SL No:2.2 of DSR-2025) | — | — | — | 56,889 | |
| details. | Breakup for | — | — | ||
| Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).(SL No:2.3 of DSR-2025) | — | — | — | 28,122 | |
| details. | Breakup for | — | — | ||
| Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (SL No:2.5 of DSR-2026) | — | — | — | 40,536 | |
| details. | Breakup for | — | — | ||
| Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (SL No:2.10 of DSR-2026) | — | — | — | 19,260 | |
| — | 25.00 | — | — | ||
| Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. (SL No:5.2 of DSR-2026) | — | — | — | 1,91,450 | |
| details. | Breakup for | — | — | ||
| "LED Down lighter (COB Type) (System lumen efficacy >-120 lm/Watt )Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F>-.0.95, IP20, CRI >80 , UGR (Unified GlareRating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >-120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector. (SL No:8.5 of DSR-2026)" | — | — | — | 5,13,000 | |
| details. | Breakup for | — | — | ||
| LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.>-0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm). (SL No:8.11 of DSR-2026) | — | — | — | 1,35,855 | |
| details. | Breakup for | — | — | ||
| Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades,30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (SL No:9.1 of DSR-2026) | — | — | — | 2,59,380 | |
| — | 30.00 | — | — | ||
| Supply and fixing of BLDC star 200 mm 20W 1600 R P M Exhaust fans including necessary plastering, Massinory work and clamps nuts bolts etc. | — | — | — | 61,740 | |
| — | 2.00 | — | — | ||
| Supply and installation of 5.0KVA, 180 / 192V DC true online UPS system IGBT technology pure sine wave out put,double conversion with auto and manual static by pass switch single phase input / Single phase output confirming to IS:13314 for inverter with cold start facility suitable for single phase AC input & single phase AC output, mains On, Inverter On Overload, Load On mains, Load On Battery, Battery Low with sealed Maintenance free (SMF) Batteries long floor mounted type of 12V 100 AH- 16 no's with battery stand. | — | — | — | 4,50,000 | |
| — | 2.00 | — | — | ||
| Supply and installation of 3.0KVA, 72V DC true online UPS system IGBT technology pure sine wave out put,double conversion with auto and manual static by pass switch single phase input / Single phase output confirming to IS:13314 for inverter with cold start facility suitable for single phase AC input & single phase AC output, mains On, Inverter On Overload, Load On mains, Load On Battery, Battery Low with sealed Maintenance free (SMF) Batteries long floor mounted type of 12V 100 AH- 8 no's with battery stand. | — | — | — | 3,00,000 | |
| — | 2.00 | — | — | ||
| Supply and installation of 2.0KVA Capacity ONLINE UPS with an isolation transformer, true on - line double conversion UPS with PSM-IGBT technology with cold start facility suitable for single phase AC input & single phase AC output, mains On, Inverter On Overload, Load On mains, Load On Battery, Battery Low with sealed Maintenance free (SMF) Batteries long floor mounted type of 12V 42 AH- 6 no's with battery stand. | — | — | — | 2,00,000 | |
| — | 2500.00 | — | — | ||
| Supply, running, Connecting of 1 core 10 Sqmm PVC heavy duty insulated mutlti stranded Copper conductor cable with necessary accessories like cable ties etc...IS 694 (2010) with latest amendements. | — | — | — | 3,30,000 | |
| — | 40.00 | — | — | ||
| Supply and Erection of B curve 6A SP MCBs of Rated Short-Circuit Breaking Capacity 10kA of IP 20 Protection ISI / CE Marked as per IS/IEC 60898 - 1 or its latest amendments Cat.Nos: 811010 with all connected accessories. | — | — | — | 9,200 | |
| — | 40.00 | — | — | ||
| Supply and Erection of B curve 10A SP MCBs of Rated Short-Circuit Breaking Capacity 10kA of IP 20 Protection ISI / CE Marked as per IS/IEC 60898 - 1 or its latest amendments Cat.Nos: 811010 with all connected accessories. | — | — | — | 9,200 | |
| — | 40.00 | — | — | ||
| Supply and Erection of B curve 16 SP MCBs of Rated Short-Circuit Breaking Capacity 10kA of IP 20 Protection ISI / CE Marked as per IS/IEC 60898 - 1 or its latest amendment Cat.Nos: 811010 with all connected accessories. | — | — | — | 9,200 | |
| — | 25.00 | — | — | ||
| Supply, fixing and connecting of 2pole 2 module 32A Lexic RCBOs conforming to IS 12640-2(2008) or latestas advised by the site supervisor with all necessary accessories complete | — | — | — | 87,447.5 | |
| — | 35.00 | — | — | ||
| Supply, fixing and connecting of 2pole 2 module 16A/25A Lexic RCBOs conforming to IS 12640-2(2008) or latest as advised by the site supervisor with all necessary accessories complete. | — | — | — | 1,18,923 | |
| — | 6.00 | — | — | ||
| Supply and erection of 63A, C-curve 3P MCBs with 10KA breaking capacity with all necessary accessories complete. | — | — | — | 12,474 | |
| — | 3.00 | — | — | ||
| Supply and fixing of 63 A 4P MCB C Curve , 10 KA capacity with necessary connections and all accessores complete. | — | — | — | 8,322 | |
| — | 2.00 | — | — | ||
| Supply and installation of 250 A 4P MCCB, 36 KA, Micro processor based adjustable with LSIG protection communcation capable conform to IEC 60947-2 model no. 4205 39 of Legrand make or it's equivalent with extended ROM , spreader links - (2 sets). | — | — | — | 81,180 | |
| — | 50.00 | — | — | ||
| Supply and fixing of 9W LED bulbs as per attached railway specification. | — | — | — | 7,872.5 | |
| — | 30.00 | — | — | ||
| Supply and erection of 100W LED Highbay light with PDC housing suitable for celing (Surface/Suspended) mounting with System efficiency 150LM/W, complete with necessary mounting accessories, clamps and hardware etc...as per attached railway specification | — | — | — | 1,88,595 | |
| — | 10.00 | — | — | ||
| Supply and Fixing of 4feet 20W LED tube light with Radar motion sensor. The fittings have to be fixed on the wall / Ceiling / FOB with suitable clamps. CCT 5700 K -6200 K Luminious flux : 1400-1600 Lpm , Input Voltage : 100-240 V , 50 Hz Power factor > 0.9, SMD LED 3014:117 Pcs , BEAM angle :180, CRI>71. Ingrees protection: IP20, base : Aluminium alloy housing cover : Forsed , PVC lamp holder : PC /ABS , Action distance : phase 3 t6 m .Suitable Box type fittings for LED lamps has to be supplied by the contractor.Make : Nano, Bright solar, ECP lighting solutions, Procorp earntech pvt ltd, solar innovation & system. LED make as per attached railway specification | — | — | — | 15,810 | |
| — | 10.00 | — | — | ||
| Supply ercetion testing and commissioningof 2 feet-8 w sensor based tube set (setincludes sensor LED tube , Housing, 1 MtrCable ) wattage :16 W @max, 3w dim , CCT5700 K - 6200 K Luminious flux : 1400-1600Lpm , Inpu Voltage : 100-240 V , 50 HzPower factor > 0.9, SMD LED 3014:117 Pcs, BEAM angale :180, CRI>71. Ingreesprotection: IP20, base : Aluminium alloycover : Forsed , PVC lamp holder : PC /ABS, Action distance : phase 3 t6 m with 120.(2) Supply of Housing for fixing LED tube.Make : Nano, Bright solar, ECP lightingsolutions, Procorp earntech pvt ltd, solarinnvation&syatem. LED 3014:117 Pcs , BEAM angle :180, CRI>71. Ingrees protection: IP20, base : Aluminium alloy housing cover : Forsed , PVC lamp holder : PC /ABS , Action distance : phase 3 t6 m .Suitable Box type fittings for LED lamps has to be supplied by the contractor.Make : Nano, Bright solar, ECP lighting solutions, Procorp earntech pvt ltd, solar innvation&syatem. LED make Nichia, CREE, Osram, Seoulsemi, samsung, Brgelux. | — | — | — | 14,342.13 | |
| — | 60.00 | — | — | ||
| Supply and fixing of 20W 4 feet LED Inverter tube light of Havell's make Model No.LHEXASP7IN1W020 or Equivalent Reputed make with all connected accessories complete for fixing (The supply includes accessories such as clamps, ties extenstion wires etc for fixing) as per attached railway specification. | — | — | — | 40,600.05 | |
| — | 5.00 | — | — | ||
| Supply and Erection of of LED flood light fittings 60 W with all connected accessories Model no; JETAIRISFLS150WLED757P2AV2WBLTG as per attached railway specification. | — | — | — | 23,210 | |
| — | 1500.00 | — | — | ||
| Supply, Laying, Testing and Termination of 4 core 120 sqmm XLPE insulated underground armoured aluminium cable with heat resistant insulation as per IS 7098(Part 1)1988 with latest amendements and with necassary lugs and terminations. | — | — | — | 12,87,600 | |
| — | 2000.00 | — | — | ||
| Supply, Laying, Testing and Termination of 4 core 95 sqmm XLPE insulated underground armoured aluminium cable with heat resistant insulation as per IS 7098(Part 1)1988 with latest amendments including laying of cable in the trench and connected and with necassary lugs and terminations at both the ends complete. | — | — | — | 10,30,480 | |
| — | 2900.00 | — | — | ||
| Supply and Erection of HDPE pipe of 75 mm of PE-100, PN6 class as per IS 4984-2016 with latest amendments and with suitable couplings and clamps for cable laying with all necessary accessories complete. | — | — | — | 5,24,900 | |
| — | 1000.00 | — | — | ||
| Supply, Laying, Testing and Termination of 1.1 KV Grade 4 core 50 sqmm XLPE insulated PVC sheathed Aluminium armoured cable as per IS 7098(Part 1)1988 with latest amendments and with necassary lugs and terminations. | — | — | — | 3,27,000 | |
| — | 2000.00 | — | — | ||
| Supply, Laying, Testing and Termination of LTUG 4 core 25 sqmm XLPE insulated PVC sheathed Aluminium armoured cable as per IS 7098(Part 1)1988 or latest amendments and with necassary lugs and terminations. | — | — | — | 3,86,000 | |
| — | 2500.00 | — | — | ||
| Supply and Erection of HDPE pipe of 50 mm of PE-100, PN6 class as per IS 4984-2016 with latest amendments and with suitable couplings and clamps for cable laying with all necessary accessories complete. | — | — | — | 2,00,000 | |
| — | 6500.00 | — | — | ||
| Supply and laying of 8 SWG GI wire with 40GSM Zink coated, conforming to IS:280- 2006 or latest, it is to be laid with armourd cable for earth continuity. | — | — | — | 78,000 | |
| — | 600.00 | — | — | ||
| Supply, laying and connecting of 25x3mm GI Flat with 40GSM Zink coated, conforming to IS:280-2006 or latest, it is to be laid & connected from equipment to earth electrode for continuity. | — | — | — | 19,800 | |
| — | 2100.00 | — | — | ||
| Excavation of cable trench in all types soil of size of size 400mm wide x 1 mtr. deep, and making good of the same to its original form and shape after complete including all connected materials and works up to the satisfaction of the Engineer at Site.The exact route of the HT/LT cable is to be decided in consultation with Engineer in charge. | — | — | — | 3,01,140 | |
| — | 600.00 | — | — | ||
| Excavation of cable trench in cement concrete bed flooring by using power drill to a depth of 1.0 Mtr and a width of 0.3mtr. After laying the pipe and refilling the trench with excavated earth and undertaking cement concrete bed flooring to its original shape as was prevailing earlier to the satisfaction of Railways site Engineer.The exact route of the HT/LT cable is to be decided in consultation with Engineer in charge. | — | — | — | 2,68,056 | |
| — | 120.00 | — | — | ||
| Excavation of cable trench under the Track/Road below 3mtrs. horizontal drilling bore with Hydrallic Jack suitable size for provision of 160/110/50mm dia GI/HDPE pipe | — | — | — | 2,58,840 | |
| — | 30.00 | — | — | ||
| Supply and Erection of Power cable route indicators with all connected materials and works as per Drawing No.DEE/CN/BZA/2001/23. | — | — | — | 3,900 | |
| — | 4.00 | — | — | ||
| Supply, Erection and connecting of Cable Junction Boxes IP 55 / IP 65 with metric knockouts for cable entry Cable junction boxes of model no. K 9255 of Hensel make or equivalent make conforming to IS:13573/92,IEC 60947-3 with necessary terminals suitable for cables upto 25 Sq mm and all necessary accessories complete. | — | — | — | 7,080 | |
| — | 2.00 | — | — | ||
| Supply, Erection and connecting of Cable Junction Boxes IP 65 with metric knockouts for cable entry Cable junction boxes of model no. K 7004 of Hensel make or equivalent make conforming to IS:13573/92, IEC 60947-3 with necessary terminals suitable for cables upto 70Sq mm and all necessary accessories complete. | — | — | — | 44,390 | |
| — | 4.00 | — | — | ||
| Supply, Erection and connecting of Cable Junction Boxes IP 55 / IP 65 with metric knockouts for cable entry Cable junction boxes of model no. K 1204 of Hensel make or equivalent make with necessary terminals suitable for cables upto 150Sq mm and all necessary accessories complete. | — | — | — | 96,480 | |
| — | 9.00 | — | — | ||
| Supply, fixing, testing, connecting and commissioning of 1.5 Ton capacity Hi wall split inverter Air conditioner 5 star rated with hermitically sealed Copper Condensor and ISEER > 5.5, R- 32 Refrigerant including all accessories & fixing of Outdoor Mounting Stand etc. with required lenght of the cables between indoor and outdoor units Note: (1) AC unit supplied to railways must match with the BEE Star Rating valid as on the date of supply. (2)The Product must be registered, on the name of Consignee, with OEM, after successful installation and the firm shall submit the BIS Certificates. | — | — | — | 4,96,603.35 | |
| — | 9.00 | — | — | ||
| Supply, installation, testing and commissioning of Energy Saver for air conditioning units for 1.5T Capacity having memory based micro controller, with Dual sensor & display for room and coil temperature, measures room /coil/ ambient temperatures- features A 10-PT programmable menu and a remote to change your set temperature, which constantly analyses the temperature transfer profiles between the air and evaporator coil. (Warranty Period : Upto 30 months from the date of delivery.) | — | — | — | 1,06,624.8 | |
| — | 9.00 | — | — | ||
| Supply, fixing, testing, connecting and commissioning of Wall Mounted Stabilizer, with auto Cut-Off, Overload Protection, Time Delay feature, suitable for 1.5 Ton capacity split Air conditioning unit complete with all connected accessories etc | — | — | — | 15,750 | |
| — | 90.00 | — | — | ||
| Supply and provision of set of copper pipes i.e. from Indoor to outdoor and outdoor to indoor unit suitable for 1.5-ton/2 ton inverter AC including foam insulation over and above of 3 mtrs. of set of pipes supplied along with AC by OEM as per site requirement | — | — | — | 72,333 | |
| — | 60.00 | — | — | ||
| Design, manufacture, display and installation of wall /hanging / floor mounting type LED illuminated sign / direction boards in Full Elliptical(FE), Half Elliptical (HE), SemiElliptical (SE), Parabolic /Triangular shape. All the specifications are as per Standard Signages at Stations On Indian Railways- April-2023 with its latest amendments. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage. The Font size and Board sizes shall be adopted as per site conditions. All Neccasary Clamping arrangements shall be provided as per the instructions of Site supervisors | — | — | — | 1,43,346.6 | |
| — | 22.00 | — | — | ||
| Supply erection, testing and commissioning of Maintenance free earthing with all necessary accessories complete according to IS 3043-1987 and as per RDSO spec No: rdso/spec/ps/0109(rev.0)-2008 Amendment'1'. | — | — | — | 3,14,886 | |
| — | 6.00 | — | — | ||
| Supply, Erection and connecting of SMC Distribution Box of size 400 x 300 x 190mm of Model No: GSJB 4030 of sintex make or equivalent make with clip on type terminal blocks suitable for 70 Sq.mm size cable. | — | — | — | 5,876.4 | |
| — | 6.00 | — | — | ||
| Supply of self contained drinking water cooler of capacity 150 Lrs cooling capacity and 150 Ltrs storage capacity, confirm to IS: 1475 (part-i) 2001 suitable for operation on 230 Volts +10%, 50 Hz single phase AC supply with latest amendments etc... | — | — | — | 2,73,474 | |
| — | 6.00 | — | — | ||
| Supply and fixing of ON Delay/Interval timer of Supply Voltage - 200V-240VAC, 50/60Hz Model - 800XU. | — | — | — | 3,468 | |
| — | 6.00 | — | — | ||
| supply and fixing of 3 Pole AC Power Contactor 25 Amp 1 NO 1NC AC 3 PH 415 V Coil Voltage 110 V AC Aux. in above junction box. | — | — | — | 5,826 | |
| — | 15.00 | — | — | ||
| Supply and erection of Digital time switch with astronomical function of model no: 4126 57 of legrand make with 2 output of 16 A - 250 VA Astronomical function 2x28 programmes 2 Channel | — | — | — | 1,57,521 | |
| — | 12.00 | — | — | ||
| Supply, Transportaion, Erection & commissioning of 5mtr long hot dip galvanised Octagonal pole (IS 875) with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet (S 355 JO steel plate for shaft), along with base plate IS 2062 of size 200x200x12mm, M16x600 long J type EN8 grade foundation bolts, 1000mm long single/ Double arm bracket Including the Supply of Suitable bolts with Bakelite Sheet with MCB ( for mounting inside the base compartment of pole ) including Erection & commissioning of 5 mtr. octagonal pole including RCC concrete foundation & plinth in hard soil including excavation of soil, tamping of concrete, grounting and supply of other required materials and accessories complete. | — | — | — | 2,20,483.2 | |
| — | 12.00 | — | — | ||
| Service connection to the fitting from the junction box of 5 mtrs Octogonal pole by means of PVC insulated copper conductor of 3 core 1.5 Sq mm with necessary lugs at the juction box and necessary termination at the luminaire complete. | — | — | — | 4,380 | |
| — | 12.00 | — | — | ||
| Supply and fixing of junction box suitable for street light poles model no.GSJB306-T of size 275mm X135mm X 110mm with 4 nos of connectors and suitable clamps for fixing , Fire retardant -Class FV-0 as per IS:11731 Part-II or V-0 as per UL-94 (fixing should be required as per instruction of site supervisor). Suitable clamps for fixing (MS Clapms 02 Sets for each Box with necessary bolts and nuts as per site condition for GI channels/poles as per the directions of Site engineer. | — | — | — | 10,200 | |
| — | 24.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CEGETechnicalCircular07-04-2022_compressed.pdf
ATTACHMENT
GCC_April-2022WithCorrectionSlips._compressed.pdf
ATTACHMENT
RlyBd-JPO-DiggingofCables2013-Re-Circulatedin2022-LATEST.pdf
ATTACHMENT
EarthingSpecificationMFEandOther.pdf
ATTACHMENT
RITESInspection.pdf
ATTACHMENT
Technicalspecifications--9-26.pdf
ATTACHMENT
Scopeofworkforwiring.pdf
ATTACHMENT
CPWDGeneralspecelectricalworks_compressed.pdf
ATTACHMENT
FirepreventionGuideline.pdf
ATTACHMENT
ListofLikelySuppliers16-10-26.pdf
ATTACHMENT
NITIREPSWorksEM-64.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .