Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹47.5 L+₹2.9 L (6.43%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | L3₹47.8 L+₹3.2 L (7.07%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L3 | Rejected-Finance HIGHER RATE | |
| 4 | L4₹47.8 L+₹3.2 L (7.14%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L4 | Rejected-Finance HIGHER RATE | |
| 5 | L5₹47.8 L+₹3.2 L (7.23%)Rejected-Finance | L5 | Rejected-Finance HIGHER RATE |
Tender Value
₹43.5 L
EMD Value
₹86,960
Closing Date
23 Sept 2024, 6:00 pmClosed
GE ARMY BHUJ
BHUJ
PROVN OF 03 X HIGH MAST LIGHTS INSIDE MH AREA AND PROVN OF SECURITY LIGHTS ELECTRIC POLES CONNECTED WORKS AND CERTAIN SANCTIONED WORKS UNDER AGE EM OF GE ARMY BHUJ
2024_MES_670807_1
8233
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹86,960
Yes
13 Nov 2024
3 Sept 2024
25 Sept 2024
3 Sept 2024
23 Sept 2024
16 Sept 2024
Amount
Supply installation and commissiong of Water cooler fully stainless steel, Food grade steel electric driven single phase having approx storage and nominal cooling cap 40/80 ltr, Longer cooling retention, Anti corrosive pre coated body, 40% Energy Efficient Compressor complete with all fixing acessories, anti corrosive pre coated body, energy efficient compressor, including suitable PCC foundation, drain pipe of suitable size complete all as specfied and directed.
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 5000 CuM per hour, honey comb pads, Whisper quiet performance with castor wheels, ice chamber,water level indicator,Four way air deflection complete all as specfied and directed.
Supply and fix double door Frost free refrigerators, electric driven (single phase), capacity 360 litres BEE 5 star, Toughened glass, Built in stablizer,smart inverter compressor,multi air flow, complete including making electrical conncetion, supply of base frame complete all as specfied and directed.
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated,Digital display, anati scalant, Anti corrosive, Buit in safe shock module, 5 in 1 safety valve ,Knob control, complete all as specfied and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA complete all as specfied and directed.
M&L for wiring with using 4 Sqmm for phase and earth (nominal area) and 2.5sqmm earth conductor multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC conduit pipe of adequate size concealed type fixed on wall / fixed to surface ceiling with PVC rawl plugs with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with modular type white plate and frame with suitable brass screws and cup washers
Supply and fix modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix switch socket modular , 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
Supply and fixing of pipe uPVC pipe including fittings of size 25 mm (1.0") dia, including tapping complete all as specified and directed.
Supply and fix ball valve 25mm dia including all fittings complete all as specfied and directed .
Supply and lay pipe uPVC pipe ASTM D-1785 sch 40 including fittings of size 50 mm (2.0") dia complete all as specified and directed.
Supply and lay pipe uPVC pipe ASTM D-1785 sch 40 including fittings of size 25 mm (1.0") dia complete all as specified and directed.
M&L for cutting of existing DI/CI pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including necessory exvation and earthwork, dewatering etc,if any involed, complete all as specified and directed for 50 / 100 mm bore of pipes complete all as specfied and directed.
Supply and fix ball valve 25 mm dia including all fittings complete all as specfied and directed.
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete all as specfied and directed.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specfied and directed.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point complete all as specfied and directed.
M&L for Construction of solid Masonary valve chamber of size 600 X 600 X 600 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core, 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, without using extra cement internally including top of floor including excavation earth work in hard/Dense soil, including 3 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Supply and fix ball valve 50 mm dia including all fittings complete all as specfied and directed.
Supply, erecting and fixing in true vertical position, prestressed concrete poles, 9 meter long having 102mm X 172mm at top and 102 mm X 279 mm at bottom class 10 poles complete with bolts, nuts & screws including painting and marking alternate white and black strips 30 cm height complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.)
Supply and fixing in replacement of Flood light fitting in new generation energy saving environemental friendly long life with die-cast aluminium alloy for housing (heat sink) for effcetive thermal managemnet, high power LED light source,zero maintenance, Lumen efficiency of LED >140lm/W, viewing angle 120 degree color temp 5700 K , made up of high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, over voltage protection, output open circuit protection,m16 gland is used for cable entry , Toughened glass, IK7 or higher and capacity 100 Watt,including MS cradle of thickness 4mm with SS angular dial GI pipe brackets of 1.5 mtr length 40mm dia or as per manufacture recommendations & all connected accesories complete all as specfied and directed.
Supply and fix in repairs Weather Proof PVC Junction Box made out of not less than 2 mm thick of size 300x200x105 mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB SP 06 Amps 10 KA - 01 No incl 02 Nos Cable Glands suitable for inserting cable not less than 50 sqmm with 02 No 01 mm GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers complete all as specfied and directed.
Supply, laying and testing cable XLPE Insulated ,PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specfied and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified & directed complete all as specfied and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m in depth and not exceeding 3.0m depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated soil to a distance not exc. 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type 1, flat as per size 250mm x 150mm x 40mm for LT cable and laid dry in trenches over underground cables complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregates as in copings, kneelers, apex stones, bed plates, kerbs etc., water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work complete all as specified and as directed.
Supply and laying 50 mm bore galvanized steel tubing, heavy grade, with all fittings laid in trenches / road / etc complete as all specified and directed.
Supply and fill dry river sand in trenches for cable cushioning over and below the cable complete all as specified and directed. ( The punned thickness shall only bev measured)
M&L for cross arms bracings, supports, clamps andback plates fabricated from structural steel sections incl nut & bolts , washers welding, bending cold or hot drilling holes for bolts, washers in any shape of size complete all as specfied and directed.
Supply and fix single point air termination aluminium rod, 12 mm dia, 300 mm long complete all as specfied and directed.
Supply and laying 40 mm bore galvanized steel tubing, medium grade (For fixing air termination rod as pipe post with all fittings laid in trenches / road / etc complete as all specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded aggregates as in copings(150x150x200 mm) for holding GI pipe kneelers, apex stones, bed plates, kerbs etc. water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on insulator or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation etc. as required of size 32 mm x 6 mm galvanised iron strip complete all as specified and directed.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall /roof on insulatoror recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25 mm x 3 mm aluminium strip complete all as specified and directed .
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron 32X6mm , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge and painting value of earth resitance and date of test on earth pit
Supply and fix test point termination block of size 75 mm x 75 mm x 25 mm made of Gun Metal or phospherous bronze drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw and box of size 90 x 90 x 90 mm (Made out of 1.6 mm thickplain brass sheet) and screwed to wall for protection of test point complete all as specified and directed.
Supply, fixing & testing of polygonal Hot Dip High galvanized steel mast light of suitable thickness conforms to BSNE 10025 grade of height 15.00 mtr from ground level suitable for 6 lantern symmetrically fitted along with their control panel , load carrying capacity of 750 Kgs or next higher capacity consisting of motor 3 phase 1.5 HP of suitable capacity to lift light frame ,motor starter , reverse and forward movement for motor of suitable capacity and compartment should provide inside the mast light and having two point suspension system with stainless steel wire rope of dia 7/19 guage with thimble and terminals and double drum winch operated by motor, self lubricated by means of oil bath ,grooved double drum with gear ratio of 53:1 ,Electrical multi core flexiable power cable with luminaire mounting arm, pully assembly, at mast head cables are conneceted to weather proof cast aluminium junction box on the luminiars carriage ,aviation obstruction light, lightning arrester spike with copper strip from top to bottom ing RCC foundation with 8 Nos Bolts as per manufacture recommendation with blots inserted in concrete including excavation,returning,removing from site ,suitable size rod for reinforcemnt for foundation, including feeder pillar for high mast light completely all as specfied and directed. Note:Drawings of Foundation ,High Mast light shall be submitted by contractor from manufacture and same to be approved from Engineer-in-charge.The foundation shall be made as per manufacture drawing.
Supply and fixing LED flood light fitting 200 Watt 230 V AC outdoor type with high pressure dia cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and directed.
M&L for heavy duty armoured LT under ground cable 1100 V grade XLPE insulated, PVC sheathed ,multi stranded aluminium cable of 16 sqmm 4core size in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces complete all as specified & directed
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete, Date of testing, vaue of earth should be mentioned on PCC pit all as specified & directed.NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ and report should be submitted after testing the earth value and paiting Earth valve on pit with date of test and due date.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/dense soil for laying of cable/ GI pipe and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing surplus soil to a distance outside MD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid separately.
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete all as specfied and directed.
Supply, erecting and fixing in true vertical position, prestressed concrete poles, 9 meter long having 102mm X 172mm at top and 102 mm X 279 mm at bottom class 10 poles complete with bolts, nuts & screws including painting and marking alternate white and black strips 30 cm height complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.)
Supply and fixing in replacement of Flood light fitting in new generation energy saving environemental friendly long life with die-cast aluminium alloy for housing (heat sink) for effcetive thermal managemnet, high power LED light source,zero maintenance, Lumen efficiency of LED >140lm/W, viewing angle 120 degree color temp 5700 K , made up of high pressure die cast aluminium housing with toughned glass ,IP66 protection , PF 0.95 ,external surge protection 10KV , seperate comparment for driver ,operating voltage 140-270 Volt, over voltage protection, output open circuit protection,m16 gland is used for cable entry , Toughened glass, IK7 or higher and capacity 100 Watt,including MS cradle of thickness 4mm with SS angular dial GI pipe brackets of 1.5 mtr length 40mm dia or as per manufacture recommendations & all connected accesories complete all as specfied and directed.
Supply and fix in repairs Weather Proof PVC Junction Box made out of not less than 2 mm thick of size 300x200x105 mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB SP 06 Amps 10 KA - 01 No incl 02 Nos Cable Glands suitable for inserting cable not less than 50 sqmm with 02 No 01 mm GI plate (150x50mm) having two holes as per the size of cable glands, fixed with cable gland for earth connectivity confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers complete all as specfied and directed.
Supply, laying and testing cable XLPE Insulated ,PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specfied and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m in depth and not exceeding 3.0m depth for foundation, laying of cable/pipe etc or for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated soil to a distance not exc. 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type 1, flat as per size 250mm x 150mm x 40mm for LT cable and laid dry in trenches over underground cables complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate in foundation, filling and mass concrete for poles/struts etc including necessary formwork as required complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregates as in copings, kneelers, apex stones, bed plates, kerbs etc., water troughs and the like including weathering, slightly rounded for chamfered angles and throating including necessary form work complete all as specified and as directed.
M&L for cross arms bracings, supports, clamps andback plates fabricated from structural steel sections incl nut & bolts , washers welding, bending cold or hot drilling holes for bolts, washers in any shape of size as indicated or directed.
Supply and laying 50 mm bore galvanized steel tubing, heavy grade, with all fittings laid in trenches / road / etc complete as all specified and directed.
Supply and fill dry river sand in trenches for cable cushioning over and below the cable complete all as specified and directed. ( The punned thickness shall only bev measured)
M&L for point wiring with 1.5 Sqmm PVC insulated sheathed fire retardant (FR) cable with multithreaded copper conductor cable in and including heavy duty 20 mm dia ISI marked concealed PVC conduit with all accessories for one light/fan point controlled by one switch with 1.25mm thick Metal boxes concealed in wall duly painted with one coat of primer and two coat of black bituminous paint ,sleek mounting plates for fixing switches regulator and including 1.5 Sqmm stranded copper conductor earth wire connected to common earth and dully complete all as specified.
(a) One exhaust fan point controlled by one way one switch SP 5 Amps, 240 V.
S&F modular switch one way 6 Amps , 1 module type complete .
S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with,Double bearing, heavy duty motor, robust construction, protective steel bird guard including making holes in any type of wall of any thickness and making holes good finishing with PCC complete all as specfied and directed.
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
Electricals India (BID ID -3108102)
ALBA AC AND REF SERVICES (BID ID -3108804)
M/s Bombay Novelty Stores (BID ID -3099825)
Shree Builders (BID ID -3106619)
ARTI CONSTRUCTION (BID ID -3108764)
Shreeganesh Construction (BID ID -3106050)
Ramdev and Sons (BID ID -3106089)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .