Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | L1 | Accepted-AOC L1 Supplier | |
| 2 | L2₹43.0 L+₹45,000 (1.06%)Rejected-AOC 8C KVB GAYATHRI NAGAR ERODE ROAD ATHUR POST KARUR KARUR TAMIL NADU 630002 | SIVAGANGA | TAMIL NADU | 630002 | L2 | Rejected-AOC L2 Supplier |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
15 Jul 2024, 3:00 pmClosed
DGM (TOS, Stores and Disposals)
TOS Kagithapuram
Miscellaneous Electrical works in Factory, Colony, Intake well, BR3 and Clonal Plant at TNPL Unit - I
2024_TNPL_453674_1
TNPL/TOS/U1/242513001504
Open Tender
Electrical related work
Tender cum Auction
365 days
TOS Kagithapuram
Tenderer should have the experience as per PQ criteria and shall submit the supporting documents for the same.
8 documents required · 8 mandatory
₹590
TNPL
₹1.1 L
13 Sept 2024
14 Jun 2024
16 Jul 2024
14 Jun 2024
15 Jul 2024
15 Jun 2024
Amount
Miscellaneous Electrical Works in Factory, Colony, Intakewell, BR#3 and Clonal Plant (The unit rates are exclusive of GST)
Cable laying work: Laying of L.T. Power/ control cables-for laying, dressing and clamping of cables-in racks, trays in concrete shafts/underground (excluding excavation & back filling)-upto 2.5 sqmm
Cable laying work:Laying of L.T.power /control cables-for laying, dressing&clamping of cables- in racks, trays, in concrete shafts/underground (excluding excavation&back filling)-above 2.5sqmm upto 35sqmm
Cable laying work:Laying of L.T.power/ control cables-for laying, dressing&clamping of cables- in racks, trays, in concrete shafts/underground (excluding excavation&back filling)-above 35sqmm upto 95sqmm
Laying of L.T. Power/ control cable/ telephone cables including charges for dressing & clamping in racks, trays, concrete shafts/underground(excluding excavation & back filling )-above 95sqmm
Cable Trays, Supports, Frames and Misc. Steel Fabrication Works: Cable removal / fixing / replacement of push button stations and/or canopy for the same.
Fabrication and erection of MS cable trays, supports, frame and Misc. Steel fabrication work including one anti-rust coat of primer, two finished coats of approved enamel paint
Removal of armoured aluminium cable from trays/underground(excluding excavation)&wind the removed cable in drum/as coil&shifting it to cable yard/other location as instructed - 3.3 KV, 3core x120sqmm cable&abv
Removal of armoured aluminium cable from trays/underground(excluding excavation)&wind the removed cable in drum/as coil&shifting it to cable yard /other location as instructed - 11 KV,3corex300 sqmm Cable&abv
Concealed wiring: Laying and Wiring in PVC concealed conduit of appropriate size between Main switch boards for single phase supply using 4.0 or 6.0 sqmm wire along with earth wire .
Concealed wiring: Laying and Wiring in PVC concealed conduit of appropriate size between Main switch boards for Three phase supply using 4.0 or 6.0 sqmm wire along with earth wire
Concealed wiring: Telephone wire in concealed PVC conduit - For single run (One Cable)
Concealed wiring: Telephone wire in concealed PVC conduit - For additional runs (more than one cable) in the same PVC Pipe
Surface wiring (Casing Capping or PVC Conduit) (Length between switch boards): Telephone wire in PVC conduit - For single run (One Cable)
Surface wiring (Casing Caping or PVC Conduit) (Length between switch boards): Telephone wire in PVC conduit – For additional runs (more than one cable) in the same PVC Pipe / casing caping
Removing of the following LT cable sizes from racks / trays concrete trenches / overhead trays / vertical shafts / undergrounds (excluding excavation) - above 35 sqmm & upto 95 sqmm
Removing the following LT cable / telephone cable from racks/ trays concrete trenches/overhead trays/ vertical shafts/undergrounds(excluding excavation) - above 95sqmm.
Surface wiring:Laying and Wiring in PVC Conduit or Casing Capping of appropriate size between Main switch boards for single phase supply using 4.0 or 6.0 sqmm wire along with earth wire
Surface wiring:Laying and Wiring in PVC Conduit or Casing Caping of appropriate size between Main switch boards for Three phase supply using 4.0 or 6.0 sqmm wire along with earth wire .
Wiring in Industrial area:Wiring of armoured / power cable in conduit from switch board to individual including installation of switch board&fitting for the following along with earth wire – 1 phase power socket.
Wiring in Industrial area:Wiring of armoured / power cable in conduit from switch board to individual including installation of switch board&fitting for the following along with earth wire - 3phase power socket.
Wiring in Industrial area:Wiring of armoured/power cable in conduit from switch board to individual including installation of switch board&fitting for the following along with earth wire - MV/SV /CFL/LED lamp.
Wiring in Industrial area:Wiring of armoured/power cable in conduit from switch board to individual including fixing of switch board&fitting for the following along with earth wire- single/twin tube light
Wiring in Industrial area:Wiring of armoured/power cable in conduit from switch board to individual including fixing of switch board&fitting for the following along with earth wire- fan®ulator/exhaust fan.
Earthing:Excavation of 2.75Mtr depth,filling with charcoal&clay,erecting electrodes,backfilling, providing necessary brick work&connection with G.I/copper Strip from earth pit to main grid(excluding electrode)
Earthing:Installation of equipment grounding for indoor&outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators, trays&grounding of structures - Earthing using 25x3GI/copper
Earthing:Installation of equipment grounding for indoor&outdoor equipment like motors, panels, MCCs, light fittings, DBs, Transformer, Generators, trays&grounding of structures- Earthing using 50x6 GI/copper.
Fixing of 63 Amps power plug unit (Fabrication, fixing frames, welding and fixing the switch)
Fixing of pull chord rope hook (Fabrication of hooks & welding)
Fixing of pull chord switch (Fabrication, fixing angles, welding & fixing the switch)
Installation and commissioning of Main Switch Board consisting of Main switch, one or more fuse cut outs, ELCB and meter - 1 phase
Installation and commissioning of Main Switch Board consisting of Main switch, one or more fuse cut outs, ELCB and meter - 3 phase
Laying of XLPE insulated steel wire armoured aluminium conductor cable in the cable trays (including dressing of cables) / underground (excluding excavation) - 3.3 KV, 3 core x 120 sqmm cable & above
Laying of XLPE insulated steel wire armoured aluminium conductor cable in the cable trays (including dressing of cables) / underground (excluding excavation) - 11 KV, 3 core x 300 sqmm cable & above
Installation of street light poles with a pole pit of 0.75x0.75x1.0M, erection of pole, concreting with 1:3:6 mix, cutting&bending of 50mm dia GI pipes for loop in/loop out in marshaling box, fixing&erection
Street Light : Dismantling of street light poles.
Post top lantern/70W street light fitting:Installation of abv luminaire on MS/GI post with a pole pit of 0.5x0.5 x0.5Mtr. Concreting with 1:3:6 mix, installation of marshaling box with loop in&loop out cabling.
Post top lantern / 70W street light fitting: Dismantling of post top lantern/70W Street light fitting.
Excavation & back filling of cable trench upto depth of 1Mtr including removal of old sand&bricks, re-laying the same/providing inverted V- shaped concrete coverings supplied by TNPL wherever required.
Excavation upto depth of 1Mtr for laying the armoured cables of all sizes&for communication cables wherever necessary 2" sand cushioning&3 side brick laying, refilling trench including cost of sand, brick etc.
Cutting of blacktop / concrete road and excavation upto a depth of 1mtr for laying pipes for cable crossing and refilling trench excluding repair of blacktop / concrete
Dismantling / fixing of single / Twin type tube light fittings / Ceiling Fans at elevations upto 10 Meter
Removing of the following LT cable sizes from racks / trays concrete trenches / overhead trays / vertical shafts / undergrounds ( excluding excavation) - upto 2.5 sqmm
Removing of the following LT cable sizes from racks / trays concrete trenches / overhead trays / vertical shafts / undergrounds (excluding excavation) - above 2.5 sqmm & upto 35 sqmm
Surface wiring:Laying&Wiring in PVC Conduit / Casing Caping between Main switch board&sub-main switch board to individual light/fan/power socket etc. using 1.5 /2.5sqmm wire along with earth length upto 5Mtrs.`
Surface wiring:Laying&Wiring in PVC Conduit / Casing Caping between Main switch board&sub-main switch board to individual light/fan/power socket etc. using 1.5/2.5sqmm wire along with earth length upto 10Mtrs.
Concealed wiring:Laying&Wiring in PVC concealed conduit between Main switch board&sub main switch board to individual light/fan/power socket etc.using1.5 or 2.5sqmm wire along with earth length upto 5Mtrs.
Concealed wiring: Laying&Wiring in PVC concealed conduit between Main switch board & sub main switch board to individual light/fan/power socket etc. using 1.5/2.5sqmm wire along with earth length upto 10Mtrs.
Termination of LT cable on both ends / straight through joint - upto 2.5 sqmm
Termination of LT cables on both ends / straight through joint - Above 2.5 sqmm & upto 35 sqmm
Termination of LT cables on both ends / straight through joint - Above 35 sqmm & upto 95 sqmm
Termination of LT cables on both ends / straight through joint - Above 95 sqmm
Termination of HT cables on both ends / straight through joint - 3.3 KV grade cable
Termination of HT cables on both ends / straight through joint - 11 KV grade cable
Fixing extra power socket with switch(5A/15A) in addition with concealed/ surface wiring between main switch board & sub main switch board to individual power socket with switch using 1.5/2.5sqmm wire.
Replacement of MCB/Fault attending in the Industrial light fitting upto 30 Mtr Elevation
Existing/old armature Cable dressing & clamping from 1.5sqmm to 300 Sq.mm
Feestoning system repair works in EOT Cranes/Soot Blowers etc
Removing of faulty and fixing of new 150W/ 250W / 400W LED light fittings with control gear at elevation upto 30 Mtr(Tower Light )-Two Way
Removing of faulty and fixing of new 36W/40W /70W /95W/150W/ 250W / 400W LED light fittings with control gear at elevation upto 15 Mtr(Street/Highbay/Focus & False Ceiling )-Two way
Removing of faulty and fixing of new LED 18W/20W/36W/40W 4ft Tube Light fittings with control gear at elevation upto 15 Mtr-Two Way
Fixing of new 36W/40W / 70W /95W/150W/ 250W / 400W LED light fittings with control gear at elevation upto 15 Mtr(Street/Highbay/Focus & False Ceiling )-One Way
Fixing of new LED 18W/20W/36W/40W 4ft Tube Light fittings with control gear at elevation upto 15 Mtr-One Way
New cable drum shifting from stores to plant/colony
Bidder Name
Amount in Words
Ravi Engineers and Contractors (BID ID -1075871)
NVN ELECTRICALS (BID ID -1072507)
Ravi Engineers and Contractors (BID ID -1075871)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .