Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹8.8 L Quoted ₹8.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹10.0 L+₹1.0 L (11.8%)Rejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹10.0 L+₹1.0 L (11.8%) | L2 | Rejected-AOC L2 |
| 3 | L3₹10.1 L+₹1.2 L (13.0%)Rejected-AOC | ₹10.1 L+₹1.2 L (13.0%) | L3 | Rejected-AOC L3 |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
14 Jun 2021, 6:00 pmClosed
GE 871 EWS
JOSHIMATH - 246443
REPAIRS REPLACEMENT OF UNSERVICEABLE INTERNAL WIRING, LIGHT FITTINGS INCLUDING OTHER EM ALLIED WORKS AND COMPREHENSIVE MAINT OF EXTERNAL WATER SUPPLY AT RUDRAPRAYAG AND GAUCHER UNDER GE 871 EWS
2021_MES_443456_1
8588/E8
Open Tender
Electrical and Maintenance Works
Works
270 days
RUDRAPRAYAG AND GAUCHER
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 871 EWS
₹23,000
Yes
7 Jul 2021
17 May 2021
16 Jun 2021
17 May 2021
14 Jun 2021
1 Jun 2021
17 May 2021 - 31 May 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls to match with existing, floors, all as specified and directed.
M&L point wiring in PVC casing & caping all as required at site of size confirming to IS 2079-1973 medium grade on surface with PVC insulated unsheathed multistranded copper conductor cable (FRLS) 1.5 sqmm nominal cross sectional area 1100 volts grade with all fittings such as elbows, bends, junction boxes, saddles including PVC board (ISI Marked) and screws and rawal plug including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbels all as specified and directed for one light/bell point controlled by one, one way switch . Make of Casing and Caping is Kalinga/ Harish/Polypac/Plaza/Gaurav and Make of PVC Copper wire : Plaza/Polycab/Havells/RR Kabeel for the following wiring :-
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 2 above but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No 2 above but for socket out let, 15/16 Amps on independent board with 4 Sqmm size cable and 2.5 Sqmm for continuty earth wire connected to common earth dolly all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way all as specified & directed. Make :Anchor/legrand/HPL
S&F in repairs of switch piano flush type 5/6 Amps single pole one way all as specified & directed. Make :Anchor/legrand/HPL
S&F switch piano flush type 15/16 Amps single pole one way all as specified & directed. Make : Anchor/legrand/HPL
S&F in replacement switch piano flush type 15/16 Amps single pole one way all as specified & directed. Make :Anchor/legrand/HPL
M&L socket out let 5 pin 5/6 Amps all as specified and directed. Make : Anchor/legrand/HPL
M&L in replacement for socket out let 5 pin 5/6 Amps all as specified and directed. Make : Anchor/legrand/HPL
S&F socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed. Make : Anchor/legrand/HPL
S&F in replacement of socket out let 2-in-1, 6 pin 5/6 & 15/16 Amps all as specified and directed. Make :Anchor/legrand/HPL
S&F bell push, flush type 5 Amps white or ivory all as specified and directed. Make : Anchor/legrand/HPL
S&F in replacement of call bell Ding Dong 230V, AC, single phase all as specified and directed. Make : Anchor/legrand/HPL
S&F in replacement plug top 15 Amp white or ivory all as specified and directed. Make : Anchor/legrand/HPL
S&F in replacement plug top 5 Amp white or ivory. Make : Anchor/legrand/HPL
S&F ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified and directed. Make :SSK/Cona/Anchor
S&F in replacement of ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified & directed. Make :SSK/Cona/Anchor
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings Make : Anchor/legrand/HPL
S&F in replacement of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings Make : Anchor/legrand/HPL
S&F stepped type electronic fan regulator flush all as specified and directed Make : Anchor/legrand/HPL
S&F in replacement stepped type electronic fan regulator flush all as specified and directed Make : Anchor/legrand/HPL
S&F 3 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make : Surya/philips/Bajaj
S&F in replacement of 3 watt LED bulb cool day light, 230/240V AC supply all as specified and directed. Make : Surya/philips/Bajaj
S&F 7 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make : Surya/philips/Bajaj
S&F in replacement of 7 watt LED bulb cool day light, 230/240V AC supply all as specified and directed. Make : Surya/philips/Bajaj
S&F 9 watt LED bulb cool day light, 230/240V AC supply all as specified and as directed. Make : Surya/philips/Bajaj
S&F in replacement of 9 watt LED bulb cool day light, 230/240V, AC supply all as specified and directed. Make : Surya/philips/Bajaj
S & F in replacement LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. Make Philips/CG/Bajaj
S&F in repalcement LED tube light fitting 2 feet 10 watt slim elegant design and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : CG/Philips/Bajaj
Supply and fixing in replacement 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light square type of suitable site as per site requirement complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. Make : wipro/Philips/Bajaj
S&F LED tube light fitting bright 18 watt slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : crompton/Philips/Baja
S&F in replacement LED tube light fitting bright 18 watt slim elegant design. and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Crompton/Philips/Bajaj
Supply and fixing in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. Make : wipro/Philips/Bajaj
Supply and fixing in replacement round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. Make : wipro/Philips/Baja
S&F building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia light grade 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed Make:- CG/ Bajaj/HPL/philips
S&F in replacement of building security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection and better optics for uniform distribution fixed bracket made out of GI pipe 32 mm dia light grade 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed Make:- philips/CG/ Bajaj/HPL
M&L in replacement of earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level and connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2020 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
Supply and fix in repairs DB, SPN 4 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/HPL
Supply and fix in repairs DB, SPN 8 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/HPL
Supply and fix in repairs DB, SPN 12 way double door for MCB, 240 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/HPL
Supply and fix in repairs DB, TPN 4 way vertical type with single/three phase outgoing with provision of MCCB as incomer 415 volt with 200 amps rated bus bar all as specified and directed Make:-Legrand/Schneider/HPL
Supply and fix in repairs MCB 6-32 amps, 10 KA, SP 240 volt, 'C' series all as specified and directed Make:-Legrand/Schneider/ HPL
Supply and fix in repairs MCB 32-40 amps, 10 KA, DP 240 volt, 'C' series all as specified and directed Make:-Legrand/Schneider/ HPL
All as per item No 45 hereinbefore but MCB DP 63 amps. Make:-Legrand/Schneider/ HPL
All as per item No 45 hereinbefore but MCB TP 63 amps. Make:-Legrand/Schneider/ HPL
Taking down/dismantling of defective/rusted storage type hot water Geyser of 50/35/25 litre capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, descaling/cleaning inner shell, servicing etc. checking defects, re-assembling and re-installing the Geyser in position, connection and testing all as specified & directed
S&F PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 450 mm long for hot/cold water (ISI marked) all as specified & directed.
S&F PVC flexible pipes 15mm dia (heavy duty) both end socketed with washer 600 mm long for hot/cold water (ISI marked) all as specified & directed.
Supply and fix stop valve fancy type cast copper alloy screwed down high pressure with crutch or butter fly handle, chromium plated screwed both ends of size 15 mm bore, for geyser connection all as specified and directed. Make : Leader/Kirloskar/L&T/Prayag/ TATA
S&F inner tank 9 holes suitable for Geyser 25 liters capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F inner tank 6 holes suitable for Geyser 25 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F inner tank 9 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F inner tank 6 holes suitable for Geyser 35 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F inner tank 9 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F inner tank 6 holes suitable for Geyser 50 litres capacity (Apparatus assembly) made copper duly prewired. Make : Usha/Lexus/Crompton
S&F indication lamp (Green/Red) as per required at site all as specified & directed.
S&F thermal Auto cut of range 0-90 degree centigrade (ISI marked) complete all as specified and directed.
S&F geyser heating element 1.5 KW (ISI marked) round type/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F geyser heating element 2 KW (ISI marked) round/thread/triangle base type with the provision of thermal cut out all as specified and directed.
S&F circular ring gasket for geyser assembly 6/9 holes as per site requirement (ISI Marked) all as specified & directed
S&F bottom plate as per existing size (ISI Marked) all as specified and directed
S&F Geyser assembly (nine holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) complete all as specified and directed
S&F Geyser assembly (six holes) suitable for 25/35/50 litres geyser capacity (ISI Marked) all as specified and directed
Taking down carefully unserviceable exhaust fans of any size from its position, dismanteling blades, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condensor, condensor holder, shackle, reassembling after replacement of defective parts including replacements of 3 core, 0.75sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging on its position properly all as specified and directed. Note :- Defective parts like ball bearing, bush bearing and motor rewinding, shaft, condensor, rubber shackle will be measured and paid separately
S&F ball /bush bearing suitable for exhaust fan of same size as that of existing defective one (ISI Marked) all as specified and directed Make : SKF/TATA/Universal/polar
S&F condenser capacity 4/3.15/2 MFD all as specified and directed. Make : Usha/Universal/ Keltran
Cleaning and preparing the surfaces of exhaust fan any size, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan all as specified and directed.
M&L burnt out rewinding exhaust fan with super enamelled bare copper conductor with the same size and number of turns as that of the old one, insulating, varnishing and pre heating for the 280 to 450 mm sweep all as specified and directed.
S&F blade suitable for exhaust fan 300/450mm, size as that of existing defective one all as specified and directed.
M&L in replacement of sub main wiring in PVC casing and caping of required size 2x6 sqmm PVC insulated multistrand copper conductor with 01x4 sqmm PVC insulated multistrand copper conductor as earth continuity wire all as specified and directed. Make : finolex/ Plaza/ Polycab Note:- For the purpose of payment two runs of 6 sqmm conductors and one run of 4sqmm conductor with casing caping will be measured as one length.
Supply and fix in replacement of cable PVC insulated multi stranded aluminium conductor 1100 volt grade heavy duty served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire of size 10 sqmm 2 core flat all as specified and directed. Make : finolex/ Plaza/ Polycab
Supply and fixing LED luminaire 600mmx600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size all as specified and directed. Make: Philips/Bajaj/wipro
Supply and fix in replacement of PVC flexible pipe of size 20 mm dia all as specified and directed.
M&L in replacement of 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable conforming to IS-694,1100 volts grade ISI Marked all as specified and directed. Make : Plaza/Polycab/Finolex.
M&L in replacement of 2.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 volts grade ISI Marked all as specified and directed. Make : Plaza/Polycab/Finolex.
M&L in replacement of 4 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 volts grade ISI Marked all as specified and directed. Make : Plaza/Polycab/Finolex.
Supply only PVC insulation tape of size 20mm dia IS marked.
Excavation in trenches in hard/dense soil nexc 1.5 metre wide and nexc 1.5 metre deep and getting out all as specified and directed.
Returning, filling in including spreading, levelling watering and well ramming in layers nexc 25 cm thick in soil all as specified and directed.
Removing excavated soil to a distance nexc 50 metre and depositing where directed at a level nexc 1.5 metre above the starting point all as specified and directed
Dismentaling and taking out old existing unserviceable GI pipe of size 80 mm dia from trenches/under floor, roads, paths or from walls/poles/ducts all as specified and directed Note:- Excavation & earth work shall be measured and paid for separately under respective item of this schedule.
All as per Item No 83 here-in-before but of size 50 mm bore
All as per Item No 83 here-in-before but of size 40 mm bore
All as per Item No 83 here-in-before but of size 25 mm bore
All as per Item No 83 here-in-before but of size 20 mm bore
All as per Item No 83 here-in-before but of size 15 mm bore
S&F 80 mm bore GI tubing medium grade with all fittings, laid in trenches, including flanges after a interval of every 03 metre length duly welded, nuts & bolts gaskets and all accesories required for completion of work all as specified and directed. Make : Jindal/Tata/Prakash Surya.
All as per Item No 89 here-in-before but of size 50 mm bore
All as per Item No 89 here-in-before but of size 40 mm bore
All as per Item No 89 here-in-before but of size 25 mm bore
All as per Item No 89 here-in-before but of size 20 mm bore
All as per Item No 89 here-in-before but of size 15 mm bore
Dismantling/taking out of old unserviceable gate valve and supply and fixing new gun metal gate valve/globe valve ISI marked with Iron wheel head screwed both end for GI tubing sizes 15 mm bore all as specified and directed. Make : Zoloto/Leader/L&T/Kirloskar
All as per Item No 95 here-in-before but of size 20 mm bore
All as per Item No 95 here-in-before but of size 25 mm bore
All as per Item No 95 here-in-before but of size 40 mm bore
All as per Item No 95 here-in-before but of size 50 mm bore
M&L for construction of PCC block walling valve pit of size 600mm x 600mm x 600mm(internal dimension) with precast cement concrete block of PCC 1:3:6 (PCC 1:3:6) type-C-1 using 20mm graded crushed stone aggregate and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and including 40 x 40 x 6 mm mild steel angle iron frame and 3 mm thick MS sheet cover with locking arrangement and 1 No 50 mm size 4 lever lock with duplicate key of make : Navtal or equivalent, including painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer all as specifiled and shown on drawing and as directed by Engr-in-Charge
M&L in replacement for (20000 litre sand filter tank) filling the following filter media in the filter bed duly cleaned and washed with 5% concentrated solution of NaOH complete including cleaning of tank as per standard procedure all as directed by Engr-in charge (a) Filter gravels (pebbles) size 1.5'' -2'' -1.4 Cum (b) Filter gravels (pebbles) size 3/41.5'' -0.9 Cum (c )Filter gravels (pebbles) size 1/2''-3/4'' - 0.3 Cum (d) Filter gravels (pebbles) size 1/4'' - 3/8'' -0.3 Cum (e) Filter gravels (pebbles) size 1/8'' - 1/4'' - 0.5 Cun (f) Fine sand op size 1/32'' -1/16'' -5 Cum
M&L in replacement of 3mm thick MS sheet top cover over the sluice valve pit/filtration tank, made with MS angle iron/channel and MS sheet with locking arrangement including pad lock and providing suitable lifting handle for each cover/valve pit including cutting, drilling, bending all as specified an directed.
Supply and Install gun metal air release double chamber valve for GI tubing and fixed of size 80 mm with all fittings as specified and including demolition/dismentling of existing gate valve as directed by the Engineer-in-Charge. Make: Kirloskar/leader/kartar
M&L in replacement of Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipes of size 80 mm dia with washers, all as specified and directed. Make : Kirloskar/leader/Kartar.
Supply and install cast iron sluice valve of size 80 mm bore class-I, PN-1:6 with gun metal spindle both ends flanged with all fittings all as specified and directed by Engr in Charge. Make : Kirloskar/leader/Kartar.
M&L for cleaning of complete water tank of 50,000 gallans capacity with chamber complete all as specified and directed by Engr-in-Charge comprising the following works :- (a) Dewatering of left out water from the tank manually or by pumping out throgh pump set (b) Taking out complete sludge/mud from the tank and removing/storing the same at low level are ermarked by Engr-in-Charge within 50 m radius. (c ) Cleaning inner surface of wall and bottom of tank with the help of wire brushes, scrapper and broom for cleaning of sludge from walls/floors (d) Washing of inner walls of tank by bleaching powder solutiion (e) Repairing of unserviceable angle/MS sheet of sedimentation tank with welding work where necessary complete all as per site requirement (f) The empty sedimentation tank shall be first cleaned with fresh water twice and therafter cleaned with fresh water sterililsed with 2% solution of potassium permagnate and writing location, capacity and date of cleaning with white paint firm and hand written over a black plate with synthetic enamel paint etc complete for entire satisfaction of Engr-in-Charge
All as per Item No 106 here-in-before but of capacity 40000 Glns
All as per Item No 106 here-in-before but of capacity 25000 litrs
S&F in replacement of galvanised iron flange on existing pipe of 80mm bore (02 Nos in each pipe) with nuts, bolts and washers all as specified and directed.
Supply only bleaching powder ISI marked grade-I in polythene bag of 25 Kg each all as specified and directed.
Supply only crystal alum suitable for potable water.
Supply only calcium Hypochlorite with chlorine content of minium 65% to 70%, Moistrure and others percentage by Mass 5 to 10%, stability loss maximum 10%, mesh passing through - 100 BSS should be max 1.5% with grannuals and quantity shall be 190 to 250 grams per one lakh litres of water to achieve one PPM at injection point available in 45 kg containers/drums of calcium based grannuals, ISI marked all as specified and directed. Make:- Sree Rayalaseema Hi Strength Hypo Ltd. Brand Name :PURI CHLOR/AQUAFIT (Chemical Division) or its equivalent make as approved by GE.
Testing of water for chemical test and bacterial test complete report in respect of water sample of Rudraprayag station from IIT Roorkee.
Submersible motor pump of set of 5 HP to 10 HP servicing by dismantling and strip opening the motor including disconnecting the cable connections and coupling of the motor, removing the starter and rotor units, bearings, servicing the motor assembly including cleaning the corbon deposits with corbon tetra chloride, greasing the bearings etc, heat varnishing the motor windings by applying varnish and keeping the windings into the hot air oven till the mositure evaporates completely at authorized workshop and refixing the same after repairs including connecting up of the electric connections including testing and commissioning and to achieve the required water discharge as per manufacturer recommendation all as specified and directed. Notes:- (i) Rates for transportation of pump sets to workshop and back to site shall be deemed to inclusive in the quoted unit rates. (ii) Spares and rewinding/heat varnishing for the motor will be measured and paid separately.
Taking out worn winding of Submersible pump motor stator of capacity 5 to 10 HP carefully and rewinding the same with existing size of super enamelled copper winding wire, including necessary varnishing and insulating material baking, etc. transportation to workshop and back at site all as directed by Engineer-in-Charge.
Supply and fixing in repairs starter for submersible motor pump of capacity 5 to 10 HP at site all as specified and directed by Engineer-in-Charge. Make : L&T, Crompton,Kirloskar
M&LPCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) in foundation filling and mass concrete all as specified and directed.
Dismantling and taking down unserviceable accessories of water supply lines of any size such as tee, union, sockets, reducers, elbow & plug IS marked as required at site to arrest the leakage of water supply line including excavation & earthwork, returning, filling, removing, cutting & threading required for under mentioned items ser item No 119 to 129 all as specified and directed at site. Note : Cost of M&L for tee, elbow, union, socket, reducer, socket, nipple, plug saddle piece of any size required at site will be measured and paid saperately under following items.
Supply and fixing GI union 25mm dia ISI marked
Supply and fixing GI union 40mm dia ISI marked
Supply and fixing GI union 50mm dia ISI marked
Supply and fixing GI union 80mm dia ISI marked
Supply and fixing GI Nipple med gde 25mm bore 100mm long ISI marked
Supply and fixing GI Nipple med gde 40mm bore 100mm long ISI marked
Supply and fixing GI Nipple med gde 50mm bore 100mm long ISI marked
Supply and fixing GI Socket 50mm bore ISI marked
Supply and fixing GI Elbow 25mm bore ISI marked
Supply and fixing GI Reducer Elbow 50x25mm bore ISI marked
Supply and fixing GI Reducer Elbow 50x20mm bore ISI marked
Ansh Enterprises
SEEMA ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .