Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
3 Jul 2023, 3:00 pmClosed
Uday Kumar (Manager)
Ph No - 9493792566
Rate Contract for Electrical Works vessels under Repairs
2023_HSL_92907_1
CD/OS/1457/SRC-RC-Electrical /311/2023
Open Tender
Miscellaneous Services
Service
30 days
Hindustan Shipyard Limited
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
Exempted
Hindustan Shipyard Limited
22 Aug 2023
3 Jun 2023
4 Jul 2023
3 Jun 2023
3 Jul 2023
9 Jun 2023
8 Jun 2023
Amount
Overhauling of AC Motors: Description & Capacity of Motors
Up to 1 K.W.
Above 1 K.W. and up to 2 K.W.
Above 2 K.W. and up to 5 K.W.
Above 5 K.W. and up to 10 K.W.
Above 10 K.W. and up to 15 K.W.
Above 15 K.W. and up to 20 K.W.
Above 20 K.W. and up to 25 K.W.
Above 25 K.W. and up to 30 K.W.
Above 30 K.W. and up to 40 K.W.
Above 40 K.W. and up to 50 K.W.
Above 50 K.W. and up to 60 K.W.
Above 60 K.W. and up to 70 K.W.
Above 70 K.W. and up to 80 K.W.
Above 80 K.W. and up to 90 K.W.
Above 90 K.W. and up to 100 K.W.
Above 100 K.W. and up to 150 K.W
Above 150 K.W. and up to 200 K.W
Above 200 K.W. and up to 250 K.W
Above 250 K.W. and up to 300 K.W
Above 300 K.W. and up to 350 K.W
Above 350 K.W. and up to 400 K.W
Above 400 K.W. and up to 500 K.W
Above 500 K.W. and up to 600 K.W
Above 600 K.W. and up to 700 K.W
Above 700 K.W. and up to 800 K.W
Above 800 K.W. and up to 900 K.W
Above 900 K.W and up to 1000 K.W
Overhauling of AC Alternators/Emergency Gnerators: Description & Capacity of Altrnators/Generators
Up to 30KVA
Above 30KVA and up to 80KVA
Above 80KVA and up to 100KVA
Above 100KVA and up to 150KVA
Above 150KVA and up to 200KVA
Above 200KVA and up to 250KVA
Above 250KVA and up to 350KVA
Above 350KVA and up to 450KVA
Above 450KVA and up to 600KVA
Above 600KVA and up to 800KVA
Above 800KVA and up to 1000KVA
Above 1000KVA and up to 1500KVA
Above 1500KVA and up to 2000KVA
Above 2000KVA and up to 2500KVA
Above 2500 KVA
Description of Work / Item(s)
Amount
DOL Starters
Star Delta Starter's
a) Upto 20 KW
b) Above 20 KW to 50 KW
c) Above 50 KW
Auto transformer starter's/Thyristor Controller's
a) upto 500 KW
b) Above 500 KW upto 750 KW
Power Distribution boards / Lighting Distribution boards
Group Control Panel
Cooking Range control panel
Main Switch Boards
Main Switch Board in Passenger Vessel
Emergency Switch Board / Pump Room Switch Boards / Accommodation Switch boards
Auxilary Switch Boards / Hydraulic Switch boards / Harbour Switch boards
Windlass Control Panel / Bow Thruster Control Panel / Mooring winch Control Panel / Davit Winch Control Panel
Windlass / Mooring winch Control Pedestal
AC Control Panel / AC Compressor Composite Control Panel
Refrigeration Control Panel / Refrigeration Composite Control Panel
AC / Refrigeration Alarm & shut down Panel / Auxiliary Engine Local Control Panel
Battery Charging Panel / Rectifier Panel
Navigation Control Panel (relay type)
Chipping and painting of Controls panels
Servicing and Repairs of Misc. Items:
Scope of work: Thorough overhauling of by cleaning and polishing of all terminal connections, proper securing of loose cables, testing of the equipment and improving insulation for satisfactory operation. Polishing of moving / fixed contacts of all the contactors, timers, relay etc as required and check insulation values of all outgoing circuits by switching of the circuit and record the insulation values and prove the insulation values of panel is in order. Renewal of components / Defective Internal Wiring (control) if any are covered in the scope of work (Spares Supplied by Ship/HSL)
Crane Resistance Boxes
Crane Controller
Cooking range with 2 hot plates and hot cup board
Cooking range with 4 hot plates and hot cup board
Rice boiler
Rice boiler with tilting mechanism
Coffee Maker / Bread Toaster / Soup Kettle
Wet Grinder
Chapati maker
Deep Flat Frier
Hot cup board / Galley Oven
Potato peeler
Mincing Machine
Washing machine (Domestic) / Hydro Extractor (Domestic) / Drying Tumbler (Domestic)
Washing machine (Industrial) / Drying Tumbler (Industrial)
Hydro Extractor (Industrial)
Dish washing machine
Iron Roller Machine
Geyser / Calorifier
Window Wiper with control unit
Tacho Generators
Welding Machine
Lighting Transformer's
a) Lighting Transformer up to 10KVA
b) Lighting Transformer 10KVA and above
c) Lighting Transformer 30KVA and above
d) Lighting Transformer 50KVA and above
e) Lighting Transformer 75KVA and above
f) Lighting Transformer 100KVA and above
g) Lighting Transformer 200KVA and above
h) Lighting Transformer 600KVA and above
Servicing and Repairs of Misc. Items:
Scope of work: Thorough overhauling of the items, check for defect, rectify the defect by renewal of components supplied by ship, renew the cabling as required and shown for satisfactory operation
1x20watt / 2x20watt Tube light fittings
1x40watt / 2x40watt Tube light fittings
Decorative/Non-decorative Cabin Bulkhead / deck head Emergency / Galley / Police / AEL / CFL / Fog / LED / Helipad / Helideck / Wall mounted light fittings
Navigation Light fittings Single Tier
Navigation Light fittings Two Tier
Wall mounted fans / Exhaust fans
Wall mounted air circulators / Stand type Air circulators
Clear View Screens
HPSV/MV Lamp Flood light fittings
Halogen light fittings
Limit Switches (Heavy duty)
Float switches
Air Circuit Breaker's
a) Air Circuit Breakers upto 300 amps
b) Air Circuit Breakers 400amps to 1000Amps
c) Air Circuit Breakers 1001amps to 2000Amps
d) Air Circuit Breakers 2001amps to 3000above
f) Air Circuit Breakers 3001amps to 4000Amps
Whip Aerials / Whip Antenna / Wire Aerials / Dipole Cage Aerials
MCCB's
a) MCCB 50 - 100amps
b) MCCB 101amps - 200 amps
c) MCCB 201amps - 300 amps
d) MCCB 301amps - 400amps
e) MCCB 401amps - 600 amps
f) MCCB 601amps - 800 amps
Multiway Junction box
AVR Units
search lights
shore supply panels
welding JB's
Food warmer / Service counter
Emergency connection boxes
For only Renewal of components : (Servicing of Panels not carried out)
Main contactor includes overload relay / Auxilary Contactor / Over Load relay seperately mounted / Timer / Rotary Switches / Single Phase Preventor
Push buttons / indication lamps / fuse with bases
Single core Power Cables in Control panels etc
Single core control cables in control panels etc.
PLA Relays with base mounting
Renewal/Replacement of MCTs along with existing cables with MS/SS frame welding
Renewal of MCBs (two / three pole)
Renewal of MCT along with MS / SS frame welding (With out cables)
Checking of Insulation Values: Check insulation values for all the following items and record the readings in presence of ship staff and submission of readings in triplicate.
Check insulation values of all the Power Distribution boards / Lighting Distribution boards / Check the cable continuity & insulation values for resitances boxes
Check Insulation resistance of all types of motors / Check Insulation resistance cable continuity for cables of all types of cores
Check Insulation resistance of all control panels
Fault Rectification / Earth Faults of Lighting Circuits
Less than 10 circuits
Above 10 circuits and less than 20 circuits
Alternator load trials upto 500KW
Alternator load trials from 501 KW to 1000KW
Alternator load trials above 1000KW
Fabrication and Renewal of Earthing strips
Collection of cable drum from ship/HSL and to cut to required length and soldering cable lugs / studs on both sides to suit with the ships intallations.
Removal and Refit of shaft earthing
ICCP system
Carryout pre docking checks and check state of ICCP Anodes, Reference Electrodes and Control Panels
Check Insulation of Anodes to hull and Reference Electrodes to hull. (After Docking and Prior to Undocking)
Remove loose scales, slime and marine growth on zinc reference electrodes by scraping with wire brush and carryout patch repairs as necessary. Scrap recess of Securing bolts / anodes / Reference Electrodes with emery paper and apply fresh coat of araldite putty in the recess. Remove marine growth & loose scales by scrapping with wooden scraper and examine the leakage where ICCP Anodes fitted. Rectify Leakages by filling with Plastic Compound
Renewal of ICCP Anodes and Reference Electrodes along with cable and welding of studs to hull as necessary.
Remove GRP Mat and carryout Surface Preparation by mechanical cleaning and buffing and renew Dielectrical Shield
Inspection of complete system including Servicing of Control Panels, Dummy Load Test, Open Loop Full Load Test and proving ICCP system value measured by Zinc Reference Electrodes
Repair of Auto Control Panel PCBs
Overhauling of Dynamo Motors
Overhauling of Self Starting Motors
Description of Work / Item(s)
Amount
a) WT Switches, WT Sockets, WT Switch Sockets and WT 2/3/4 way Junction boxes, WT On / Off Push Button Switches
b) Renewal of foundations for the above if required
a) Cabin type Switches, Sockets, Switch sockets, Push switches and 2/3/4 way Junction boxes
b) Renewal of foundations for the above if required
a) 1x20watt / 2x20watt Tube light fittings
b) Renewal of foundations for the above if required
a) 1x40watt / 2x40watt Tube light fittings
b) Renewal of foundations for the above if required
a) Decorative/Non-decorative Cabin Bulkhead / deck head Emergency / Galley / Police / AEL / CFL / Fog / LED / Helipad / Helideck /wall mounted light fittings
b) Renewal of foundations for the above if required
a) Watertight deck head 'U' glass / Bulk head fittings
b) Renewal of foundations for the above if required
a) MCB with Gang box
b) Renewal of foundations for the above if required
Garland (Incl holder, cable & lights)
a) Mirror lights
b) Renewal of MS foundations for the above if required
Spot lights
Table lamps
Berth lamps/Bunk lights
a) Halogen light fittings (W/T and NWT)
b) Renewal of foundations for the above if required
Flood light fittings/Search light fittings WT/NWT (Sodium vapour lamp / Mercury vapour lamp)
b) Renewal of foundations for the above if required
a) Ballast box WT/NWT (Sodium vapour lamp / Mercury vapour lamp)
b) Renewal of foundations for the above if required
a) Navigation lights Single/ Two tier on Main Mast
b) Renewal of foundations for Nav. Lights on Main Mast
a) Navigation lights Single/ Two tier other than Main Mast
b) Renewal of foundations for Nav. lights other than Main Mast
a) Broad Cast / Public Address system Speakers
b) Renewal of foundations for the above if required
a) Fire Alarm Bells
b) Renewal of foundations for the above if required
a) Bulk head Telephone
b) Renewal of foundations for the above if required
Desk Telephones
a) Sound Power Telephones
b) Renewal of foundations for the above if required
a) Sound Power Junction Box with multi way connections
b) Renewal of foundations for the above if required
a) Wall mounted fans
b) Renewal of foundations for the above if required
a) Wall mounted air circulators
b) Renewal of foundations for the above if required
a) Fire / Smoke Detectors
b) Renewal of foundations for the above if required
Stand type Air circulators
Television along with accessories
Computer Monitor, CPU, Key Board (Complete Set)
Renewal of foundations/Securings for the above if required (Sl.Nos 27, 28 & 29)
Local Push Button Station (or) Emergency Stop Switches
a) Crane Controller
b) Renewal of foundations for the above if required
24Volts Battery
12Volts Battery
2/6 Volts Battery
a) Limit Switches (light duty)
b) Renewal of foundations for the above if required
a) Limit Switches (Heavy duty)
b) Renewal of foundations for the above if required
a) Wip Aerials
b) Renewal of foundations for the above if required
Wire Aerials
a) Antennas
b) Renewal of foundations for the above if required
a) Window Wiper with control unit
b) Renewal of foundations for the above if required
a) Magnetic sensors for bottom doors / suction and discharge valves
b) Renewal of foundations for the above if required
Single packed cable glands
Multi way cable gland along with gland plate.
a) RPM Sensor
b) Renewal of foundations for the above if required
a) Float Switches for bilges
b) Renewal of foundations for the above if required
a) Tank Lever Sensors
b) Renewal of foundations for the above if required
a) Digital Pressure / temp / RPM indicators
b) Renewal of foundations for the above if required
Solenoids
ME/AER Engine stop solenoids
Tacho Generators
Fog Horn
Air Horn
Renewal of foundations for Fog horn / Air horn if required
a) Gyro Compass/Magnetic compass
b) Renewal of foundations for the above if required
a) Gyro Repeaters
b) Renewal of foundations for the above if required
a) Gyro Display unit
b) Renewal of foundations for the above if required
a) Gyro Alarm Unit
b) Renewal of foundations for the above if required
a) Gyro Operation Panel/Power supply unit
b) Renewal of foundations for the above if required
a) Echo Sounder Recorder
b) Renewal of foundations for the above if required
a) Echo Sounder Display unit
b) Renewal of foundations for the above if required
Echo Sounder / Log Transducer with cable connected up to Junction Box
Multi beam Echo sounder transducer unit
Multi beam Echo sounder display unit
a) Log Recorder
b) Renewal of foundations for the above if required
Log Transducer
a) Log Indicator
b) Renewal of foundations for the above if required
a) Radar Display Unit
b) Renewal of foundations for the above if required
a) Radar Transmitter/Sleave transmitter unit
b) Renewal of foundations for the above if required
a) Radar Wave Guide / antenna cable
b) Renewal of foundations for the above if required
a) Radar antenna/Radar signal processing unit
b) Renewal of foundations for the above if required
a) Telephone Exchange
b) Renewal of foundations for the above if required
a) Rudder Angle indicator
b) Renewal of foundations for the above if required
a) Rudder Angle transmitter
b) Renewal of foundations for the above if required
a) ME remote control panel
b) Renewal of foundations for the above if required
Welding Machine
Bench Grinding Machine
Switch board meters, viz., Ammeter, Voltmeter, Frequency meter, KW meter, Power Factor meter, Phase Sequence meter, etc.
Winch Control Pedestal
Water Coolers
Water filter
Renewal of foundations for the above if required(Sl. 80 & 81)
Mosquito Repeller
a) Hot Cup Board
b) Renewal of foundations for the above if required
a) Cooking Range with 2 hot plates and hot cup board
b) Renewal of foundations for the above if required
a) Cooking Range with multiple hot plates (more than 2nos) with hot cup board.
b) Renewal of foundations for the above if required
a) Frying Pan / Deep Flat Fryer
b) Renewal of foundations for the above if required
a) Chapati maker
b) Renewal of foundations for the above if required
a) Rice Boiler
b) Renewal of foundations for the above if required
a) Geyser / Calorifier along with connecting pipes up to 1st socket and connecting cables
b) Renewal of foundations for the above if required
Wet Grinder domestic model (fixed model)
a) Wet Grinder Marine model of heavy duty
b) Renewal of foundations for the above if required
Coffee Maker
Bread Toaster
Potato peeler
Ice Cream machine
Mincing Machine
Soup Kettle
a) Refrigerator
b) Renewal of foundations along with securing arrangements for the above if required
a) Food Warmer/Service counter/Food warmer cum service counter
b) Renewal of foundations for the above if required
a) Washing machine (Domestic) 8Kgs
b) Renewal of foundations for the above if required
a) Hydro Extractor (Domestic)
b) Renewal of foundations for the above if required
a) Drying Tumbler (Domestic)
b) Renewal of foundations for the above if required
Washing Machine (Industrial) - 40Kgs/18ltrs and above
a) Insitu Shifting of Washing Machine (Industrial) - 40Kgs/18ltrs and above
b) Remove , Shift to workshop & refit or Renewal of washing machine if required
c) Renewal of foundation if required for above
Hydro extractor (Industrial )
a) Insitu Shifting of Hydro extractor (Industrial )
b) Remove , Shift to workshop & refit or Renewal of Hydro extractor if required
c) Renewal of foundation if required for above
Drying tumbler (Industrial)
a) Insitu Shifting of Drying tumbler (Industrial)
b) Remove , Shift to workshop & refit or Renewal of Drying tumbler if required
c) Renewal of foundation if required for above
d) Dish washing machine
e) Renewal of foundations for the above if required
Lighting Transformer's
a) Lighting Transformer up to 10KVA
b) Lighting Transformer 20KVA and below
c) Lighting Transformer 30KVA and below
d) Lighting Transformer 40KVA and below
e) Lighting Transformer 50KVA and below
f) Lighting Transformer 75KVA and below
g) Lighting Transformer 100KVA andbelow
h) Lighting Transformer 200KVA and below
i) Lighting Transformer 300KVA and below
j) Lighting Transformer 400KVA and below
k) Lighting Transformer 500KVA and below
l) Lighting Transformer 600KVA and below
m) Renewal of foundations for transformers if required
Cable's
a) 1 core up to 4sqmm
b) 1 core 10sqmm and below
c) 1 core 25sqmm and below
d) 1 core 50 sqmm and below
e) 1 core 95sqmm and below / Welding Cable / Battery Cable
f) 1 core 120sqmm and below
g) 1 core 150sqmm and above
h) 1 core 240sqmm and above up to 320sqmm
i) 2/3/4 core cables 4sqmm and below
j) 2/3/4 core cables 10sqmm and below
k) 2/3/4 core cables 25sqmm and below
l) 2/3 core 50sqmm and below
m) 3 core 95sqmm and below
n) 3 core 120sqmm
o) 3-1/2 core 120sqmm
p) 3-1/2 core 240sqmm
q) 3-1/2 core 400sqmm
r) Co-axial cable / Telephone Data Cable / RF Cable
s) Temperature compensation cable (Thermo couple cables)
t) Multicore 5/7 core cable and above
u) Multicore 12/16 core cable and above
v) Multicore 24/36 core cable and above
w) Removal and Refit of emergency cables including minor repairs
Cable Conduit's
a) Cable conduits 1” and below
b) Cable conduit 2” and below
c) Cable conduit 3” and below
d) Cable conduit 4” and below
e) Cable conduit 5” and below
Casing / Caping along with cables (Without disturb end connections)
a) Casing / caping along with cables (without disturb end connections) 25mm wide and below
b) Casing / caping along with cables (without disturb end connections) 50mm wide and below
Flat bar channel along with cables (without disturbing end connections)
a) Flat bar channel along with cables (without disturbing end connections) 20mm and below
b) Flat bar channel along with cables (without disturbing end connections) 30mm and below
c) Flat bar channel along with cables (without disturbing end connections) 40mm and below
d) Flat bar channel along with cables (without disturbing end connections) 50mm and below
Cable channels along with cables (without disturbing end connections)
a) Cable channels along with cables (without disturbing end connections) 50mm and below
b) Cable channels along with cables (without disturbing end connections) 100mm and below
c) Cable channels along with cables (without disturbing end connections) 150mm and below
d) Cable channels along with cables (without disturbing end connections) 200mm and below
e) Cable channels along with cables (without disturbing end connections) 250mm and below
f) Cable channels along with cables (without disturbing end connections) 300mm and below
g) Cable channels along with cables (without disturbing end connections) 500mm and below
h) Cable channels along with cables (without disturbing end connections) 1000mm and below
Removal of existing cable bunch from channel and removal of cable tray and repositioning / Renewal of cable tray and securing of cable bunch for the following cable trays sizes including foundation Clamps renewal.
a) Cable tray up to 50mm and below
b) Cable tray 100mm and above
c) Cable tray 200mm and above
d) Cable tray 300mm and above
e) Cable tray 600mm and above
f) Renewal of foundation clamps for cable trays if required (where renewal of cable trays not done)
RTD Sensors
PT 100 Sensors
Thermo couples
Pressure Transmitter
Temperature Switches
Temperature gauges
Exhaust Gas temperature Scanner / Indicator
Junction box with multiple connections
a) upto 100X100 mm
b) above 100X100mm upto 300X300 mm
c) above 300X300 mm
d) Renewal of foundations for the above if required
MCCB's
a) MCCB 50 - 100amps
b) MCCB 101amps - 200 amps
c) MCCB 201amps - 300 amps
d) MCCB 301amps - 400amps
e) MCCB 401amps - 600 amps
f) MCCB 601amps - 800 amps
g) Renewal of foundation if required for above
Air Circuit Breaker's
a) Air Circuit Breakers 300amps and below
b) Air Circuit Breakers 301amps to 1000Amps
c) Air Circuit Breakers 1001amps to 2000Amps
d) Air Circuit Breakers 2001amps to 3000above
e) Air Circuit Breakers 3001amps andto 4000Amps
a) VHF Connection Unit/Convertor init
b) Renewal of foundation if required for above
a) Normal/ EMG Change Over switch with box
b) Renewal of foundation if required for above
Space Heaters in various panels /Gen/ motors/ Equipment
a) Atta Machine
b) Renewal of foundation if required for above
a) Submersible p/p Sockets
b) Renewal of foundation if required for above
a) Duty Watch Alarm Signal Panel
b) Renewal of foundation if required for above
Vibration Mounts for Control Panel, Light Fittings etc
Electrical Hoist Crane's
a) Electrical hoist Cranes 1 tons to 2tons
b) Electrical hoist Cranes 3tons to 5 tons
a) Wind Direction / Speed Transmitter Unit on Mast/ Wind Speed/ Direction Indicator Unit
b) Renewal of foundation if required for above
a) Alternator AVR Units
b) Renewal of foundation if required for above
a) Defroasting Heaters For Cool And Cold Rooms
b) Renewal of foundation if required for above
a) R/R of Camera (all types)
b) Renewal of foundation if required for above
a) Dish Antenna
b) Renewal of foundation if required for above
a) VHF / HF Set
b) Renewal of foundation if required for above
a) G.P.S System
b) Renewal of foundation if required for above
a) Antenna Tuning / Coupler Unit
b) Renewal of foundation if required for above
a) Telephone Exchange
b) Renewal of foundation if required for above
a) Fire Patrol Control Panel
b) Renewal of foundation if required for above
a) Sprinkler Alarm Panel
b) Renewal of foundation if required for above
a) Salinometer / Salinometer Sensor Assembly
b) Renewal of foundation if required for above
a) XBT Control Panel -37Amps XBT Launcher
b) Renewal of foundation if required for above
a) NAVTEX Receiver
b) Renewal of foundation if required for above
a) Clutch Control Panel
b) Renewal of foundation if required for above
Dimmer Unit
S.F.O. Door Locking Switch
a) Hooter unit
b) Renewal of foundation if required for above
a) Intercom Amplifier/ Talk back system panel
b) Renewal of foundation if required for above
Arrangement of Blowers for steel renewals /Painting works. Scope of work includes collection of blowers from pool section/electrical work shop, shift on board to the respective position, electrical connection, run the blower and maintain for continous run.
Steering Gear Bridge Console
Pressure Indicators / Level indicators / Vaccum Indicators
Microphone With stand
Thermostats
Idly Making Machine
Synchroscope Meter
Fabrication of Microphone Box
Renewal of Bus bars for MSB / Shore Supply Boxes
Arrangement, Maintenance and Removal after work completion of Temporary Guard Lights at various positions. ( Positions are subject to requirement of users) Machinery compartments, Superstructure, Cargo Tanks & Ballast Tanks etc., b) Arrangement 440V/48V Transformers and Switch Boards as per the requirement on vessel c) Laying of Cables as per the requirement for Guard Lights, Switch boards & Transformers etc.,
Maintenance of above, every week, 2 shifts per day, 2 persons per each shift & each shift 8hrs
Removal and Refit of Panel's and their Foundation's
a) Size of the panel upto 250mm x 250mm
b) Renewal of foundations for the above if required
c) Size of the panel 250mm x 250mm above upto 500mm x 500mm
d) Renewal of foundations for the above if required
e) Size of the panel 500mm x 500mm above upto 1000mm x 1000mm
f) Renewal of foundations for the above if required
g) Size of the panel 1000mm x 1000mm above upto 2000mm x 2000mm
h) Renewal of foundations for the above if required
i) Size of the panel 2000mm x 2000mm above
j) Renewal of foundations for the above if required
NOTE: 1. Preparation of drawing showing the layout of the room and position of the units which are being degutted and obtaining the countersign from ship / HSL officer. 2. If the items under removal are bad in shape/ damaged/ defective the same should be mentioned in the drawing prepared by the contractor and shall be certified by the ship / HSL. Otherwise, the responsibility lies with the contractor for proper replacement. 3. If any items found damaged due to mis-handling the same should be replaced by the contractor failing which, suitable amount shall be deducted from the running bills with HSL. 4. The items removed are in bad shape and same will be replaced by HSL/Ship staff and no additional cost for replacement and same is covered in the scope of contractor. However, any modification to the foundation is to be carried out, the same will be paid on separate head. Further, it is the responsibility of contractor to bring the deviations to the notice of the concerned production engineer and certified. 5. Considering the extra efforts to put in for renewal of cables instead of regutting of old cables, 10% extra will be considered on the quoted prices. 6. Considering the less efforts to put in for removal / regutting/renewal of flexible conduits an amount of 25% on the quoted prices on GI conduits will be considered. 7. The Units pertaining to Navigational aids shall be taken up by the contractor in presence of Service Engineers. 8. All the units / cables / components which are removed and can’t shifted from ship and store in work shop / HSL stores shall be properly secured in systemic way and to protect from hot works. 9. The removal / reconnection of removed units/components/cables is covered in the scope. 10. Cables are to be dressed properly prior to connect back to the system. 11. The system to be checked for prior to degutting. If HSL/SHIP is not willing to show prior to degutting, the same to be mentioned in the survey report. 12. Date of starting and completion shall be mentioned in each drawing and should contain the signatures of ship staff /HSL. 13. Quantities indicated above are only for guidance and for evaluation of L1 status; however, the quantum of work is depending on the kind of vessels come for repairs. 14. The quantities indicated are expected scope of work for 2 years period and may increase / decrease. 15. Removal/refit of obstructions such as insulation, paneling are not covered in the tender scope. All other in way obstructions, viz., clearing of compound from coamings and refil the compound are included in scope of work. 16. Considering the extra effort to put in for carrying out the jobs in connection with Flame Proof panels/Switches/sockets/switch sockets/light fittings, etc., 50% extra on the quoted prices will be considered. 17. Considering the extra efforts for laying of new cables instead of R/R of old cables, 10% extra will be considered on the quoted prices. 18. For installation of above equipment, 50% of above amount shall be paid extra in order to install the same as per drawing and STW of the same. 19. Only removal of old cables / equipments above, an amount of 50% less to be considered. 20. In order to determine the rate payable for foundation and removal & refitment, nearest size shall be considered. 21. Above rates shall be exclusive of Applicable Taxes.
DELTA MARINE ENGINEERS
SRI VENKATA SAI CONSTRUCTION
SRI VINAYAKA MARINE SERVICES
VIJAYA TECHNO ENTERPRISES
RAO ELECTRICAL ENGINEERIONG WORKS
SRI VENKATA SAI CONSTRUCTION
SRI VINAYAKA MARINE SERVICES
DELTA MARINE ENGINEERS
VIJAYA TECHNO ENTERPRISES
RAO ELECTRICAL ENGINEERIONG WORKS
DELTA MARINE ENGINEERS
SRI VINAYAKA MARINE SERVICES
SRI VENKATA SAI CONSTRUCTION
RAO ELECTRICAL ENGINEERIONG WORKS
VIJAYA TECHNO ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .