| 1 | L1₹16.3 LAccepted-AOC HAVELI FALIYA NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | ₹16.3 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹18.2 LRejected-Finance GEETA COTTAGE NO 3 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 | KACHCHH | GUJARAT | 370001 | ₹18.2 L | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹18.4 LRejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | ₹18.4 L | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹18.5 LRejected-Finance | ₹18.5 L | L4 | Rejected-Finance Not lowest bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical DOCUMENTS NOT AS PER PARA 4 AND 8 (B) OF APPX A TO NIT |
| Sl No | Description | Qty | Unit | Krishna Engineering L3 | AARTI ENTERPRISES L2 | GEE CEE ENTERPRISES L1 | MK Aircon Systems Pvt. Ltd. L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and install 1.5 TR hi wall split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity as shown Complete all as specified & directed by Engineer-in-Charge. | 3 | Each | 49,000 ₹1.5 L | 54,000 ₹1.6 L | 48,000 ₹1.4 L | 55,745 ₹1.7 L |
| 2.00 | Supply and install Electronic wall mounting type stabilizer suitable for AC up to 1.5 TR Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of 2.5% and of capacity 4.0 KVA (Make: AE/ V Guard/ other specified makes) complete all as specified & directed by Engineer-in-Charge. | 3 | Each | 5,000 ₹15,000 | 4,500 ₹13,500 | 4,000 ₹12,000 | 12,357 ₹37,071 |
| 3.00 | S & F industrial plug and socket with single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity complete all as specified & directed by Engineer-in-Charge. | 4 | Each | 2,500 ₹10,000 | 1,500 ₹6,000 | 1,800 ₹7,200 | 2,285 ₹9,140 |
| 4.00 | Supply and install 2 TR hi wall split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ionizer and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity as shown Complete all as specified & directed by Engineer-in-Charge. | 1 | Each | 63,000 ₹63,000 | 55,500 ₹55,500 | 58,000 ₹58,000 | 62,837 ₹62,837 |
| 5.00 | Supply and install Electronic wall mounting type stabilizer suitable for AC up to 2.0 TR Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ±2.5% and of capacity 5.0 KVA (Make: AE/ V Guard) Complete all as specified & directed by Engineer-in-Charge. | 1 | Each | 6,500 ₹6,500 | 4,700 ₹4,700 | 4,500 ₹4,500 | 12,434 ₹12,434 |
| 6.00 | S & F in replacement of GI Stand suitable for outdoor of 1.5/2 Ton AC including nut, bolt, dismantle of outdoor after returning gas, fix on GI stand connect outdoor with indoor, testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Note:- Copper tubes paid separately if additional required. | 4 | Each Job | 2,500 ₹10,000 | 900 ₹3,600 | 1,800 ₹7,200 | 2,252 ₹9,008 |
| 7.00 | S&F in replacement of copper tubing (of dia 1/4" to 1/2" ) suction and liquid line from indoor to outdoor unit by compressing Ref Gas suitable for split AC of capacity 1.5 TR/ 2.0 TR including insulation on copper tubing complete all as specified & directed by Engineer-in-Charge. Note:- Each running metre included complete set of suction and discharge line) | 20 | RUNNING METRE | 300 ₹6,000 | 900 ₹18,000 | 150 ₹3,000 | 1,479 ₹29,580 |
| 8.00 | Supply, install, testing and commissioning of Packaged AC 11 TR, 132000 Btu/Hr, 4400 CFM Air Cooled with non-inverter Scroll Compressor, micro processor control panel with inbuilt logic with LCD display, centrifugal forward curved, double inlet, double width, efficient and eco friendly R410 A refrigerant circuit with 2 Nos of condensing unit, installation on double rubber pads, Nitrogen pressure testing at 5600 Psig hold for 48 hours and vacuming the system at 500 micron, R410A Gas charging as per OEM, air balancing with CFM & testing including all copper pipe for refrigerent and drain pipe required for istallation, complete all as specified and as directed. Make : Bule Star, Voltas, Carrier, Daikin, Hitachi/other specified makes. | 3 | Each | 4,10,000 ₹12.3 L | 4,13,600 ₹12.4 L | 3,89,000 ₹11.7 L | 3,46,408 ₹10.4 L |
| 9.00 | S&F refrigerant hard copper piping for any capacity Package AC Air Cooled, Double circuit with proper supporting with anchor fastning, threaded rods, MS angle/flat support with all the necessary accessories including copper pipe of size as per OEM complete all as specified & directed by Engineer-in-Charge. | 30 | RUNNING METRE | 1,345 ₹40,350 | 3,000 ₹90,000 | 800 ₹24,000 | 2,220 ₹66,600 |
| 10.00 | S&F 40mm dia PVC pipes with necessary fitting with 9mm thick, nitrite rubber insulation with UV protection aluminium foil on sun exposed pipe complete all as specified & directed by Engineer-in-Charge. | 24 | RUNNING METRE | 290 ₹6,960 | 350 ₹8,400 | 100 ₹2,400 | 502 ₹12,048 |
Updated dates
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Nov 2025, 6:00 pmClosed
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
SPECIAL REPAIR CENTRALIZED AIR CONDITIONERS FITTED IN RUBBER STORE AND IMMOLS SERVER ROOM IN IGS SECTION AT AF STN NALIYA
2025_MES_733926_1
85308/E8
Open Tender
Electrical and Maintenance Works
180 days
NALIYA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) NALIYA
₹40,000
Yes
31 Dec 2025
7 Oct 2025
7 Nov 2025
7 Oct 2025
4 Nov 2025
21 Oct 2025
Amount
Supply and install 1.5 TR hi wall split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity as shown Complete all as specified & directed by Engineer-in-Charge.
Supply and install Electronic wall mounting type stabilizer suitable for AC up to 1.5 TR Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of 2.5% and of capacity 4.0 KVA (Make: AE/ V Guard/ other specified makes) complete all as specified & directed by Engineer-in-Charge.
S & F industrial plug and socket with single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity complete all as specified & directed by Engineer-in-Charge.
Supply and install 2 TR hi wall split units indoor/outdoor complete with cordless remote control unit and with inbuilt air ionizer and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity as shown Complete all as specified & directed by Engineer-in-Charge.
Supply and install Electronic wall mounting type stabilizer suitable for AC up to 2.0 TR Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ±2.5% and of capacity 5.0 KVA (Make: AE/ V Guard) Complete all as specified & directed by Engineer-in-Charge.
S & F in replacement of GI Stand suitable for outdoor of 1.5/2 Ton AC including nut, bolt, dismantle of outdoor after returning gas, fix on GI stand connect outdoor with indoor, testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Note:- Copper tubes paid separately if additional required.
S&F in replacement of copper tubing (of dia 1/4" to 1/2" ) suction and liquid line from indoor to outdoor unit by compressing Ref Gas suitable for split AC of capacity 1.5 TR/ 2.0 TR including insulation on copper tubing complete all as specified & directed by Engineer-in-Charge. Note:- Each running metre included complete set of suction and discharge line)
Supply, install, testing and commissioning of Packaged AC 11 TR, 132000 Btu/Hr, 4400 CFM Air Cooled with non-inverter Scroll Compressor, micro processor control panel with inbuilt logic with LCD display, centrifugal forward curved, double inlet, double width, efficient and eco friendly R410 A refrigerant circuit with 2 Nos of condensing unit, installation on double rubber pads, Nitrogen pressure testing at 5600 Psig hold for 48 hours and vacuming the system at 500 micron, R410A Gas charging as per OEM, air balancing with CFM & testing including all copper pipe for refrigerent and drain pipe required for istallation, complete all as specified and as directed. Make : Bule Star, Voltas, Carrier, Daikin, Hitachi/other specified makes.
S&F refrigerant hard copper piping for any capacity Package AC Air Cooled, Double circuit with proper supporting with anchor fastning, threaded rods, MS angle/flat support with all the necessary accessories including copper pipe of size as per OEM complete all as specified & directed by Engineer-in-Charge.
S&F 40mm dia PVC pipes with necessary fitting with 9mm thick, nitrite rubber insulation with UV protection aluminium foil on sun exposed pipe complete all as specified & directed by Engineer-in-Charge.
S&F canvas connection with zip to measure machine outlet temperature and CFM complete all as Specified & directed by Engineer-in-Charge.
Supply, fix, testing and commissioning of electrical communication cabling with earthing between indoor unit and outdoor unit complete all as specified & directed by Engineer-in-Charge.
S&F GI air tight ducting & plenums fabricated out of prime quality 120 GSM GI sheets comply with BIS code, complete with necessary supports, expansion fasteners, scaffolding to hang the ducts etc of 20 Guage GI Ducting complete all as specified & directed by Engineer-in-Charge.
S&F acoustic insulation for ducts with 12mm thick fiberglass of density 48 kg/cum & covered with RP tissue & 28 guage perforated aluminium sheet from inside of the duct complete all as specified and as directed. Make : Kimmco / Uptwiga/equivalent as approved by GE.
S&F GI Duct damper with adjustable handle to control the volume complete all as specified and as directed. Make : Airmaster/ Carryaire / Cosmos / Dynacraft / Trox / Sachins / System air / Maheswari/ equivalent specified makes.
M & L for dismantling & taking down any type AC including indoor and outdoor unit, of any capacity from installed site, transporting to MES store yard and depositing to MES carefully without damaging any part or body complete all as specified & directed by Engineer-in-Charge.
Supply and fixing/drawing wiring for Circuit / Sub main wiring with PVC casing caping of suitable size inclusive of all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories including all fixtures /fittings fixed on wall/ceiling along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required of 2 x 4.0 sqmm and 1 x 4.0 sqmm as earth wire complete all as specified & directed by Engineer-in-Charge.
S&F sub main wiring drawing through PVC casing caping with two single core 10 sq mm and one run of 10 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade Complete all as specified & directed by Engineer-in-Charge.
S&F of MCB DB SPN 8 ways single door with 240 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall complete all as specified & directed by Engineer-in-Charge.
S&F of MCB DB SPN 4 ways single door with 240 Volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall complete all as specified & directed by Engineer-in-Charge.
S&F MCB's single pole, 6 to 32 Amps, 230 volts with 'C' curve, fixed in sheet metal board complete including connecting complete all as specified & directed by Engineer-in-Charge.
S&F MCB's single pole & neutral, 40 to 63 Amps, 230 volts with 'C' curve, fixed in sheet metal board complete including connecting complete all as specified & directed by Engineer-in-Charge.
M & L for earthing complete with GI earth plate electrode 60x60cmx 5 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including provision of GI protection pipe light grade of 25mm bore and connected to earth wire earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore medium grade, wire mesh and lugs, test point including salt, coal etc. complete as specified or indicated including testing on completion complete all as specified & directed by Engineer-in-Charge.
M & L in replacement of earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provision of HDPE protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete all as directed by Engineer-in-Charge. Note: GI strip exceeding 7.5m long shall be measured & paid seperately.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm GI strip with PVC sleeve and welding at joint all as directed by Engineer-in-Charge.
AARTI ENTERPRISES (BID ID -3461641)
Krishna Engineering (BID ID -3461133)
MK Aircon Systems Pvt. Ltd. (BID ID -3466559)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
85308TENDERDOC.rar
Tender Documents • 9.35 MB
BOQ_821778.xls
BOQ • 1.09 MB
Download all tender documents and submit your bid