Executive Engineer
GENERATION DIVISION LJHP GANTAMULLA BARAMULLA
Inspection and Relay Testing of complete control and protection system of power house for 3 into 35 MW LJHP power house
2021_SPDC_155578_1
E NIT No 28 of 2021-22 Dated 30.12.2021
Open Tender
Electrical Works
Item Rate
30 days
LJHP Power House
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,500
Yes
Executive Engineer
Exempted
17 Feb 2022
31 Dec 2021
11 Jan 2022
31 Dec 2021
10 Jan 2022
31 Dec 2021
Amount
Complete cleaning, inspection & relay testing (Secondary injection testing) of Electro mechanical relays installed for three Units in LJHP power house as per standard operating procedures (SOPs) & standards and correction/ replacement is to be done, if required. The main relays installed at C&R panels are as following: a. Generator Differential Relay CAG type - 1 No b. Over Voltage Relay VDG type - 1 No c. Restricted E/F Relay CAG type - 1 No d. Auxilliary Generator Over flux - 1 No e. Auxilliary PT fuse relay - 2 No f. GTT (98/98A) - 1 No g. Definite Time relay (VAT) - 1 No h. Negative Phase Sequence Relay - 1 No i. AVR PT fuse failure supplementary relay - 1 No j. Instantaneous Over Voltage relay type VAGM - 1 No k. Metering & Protection PT fuse failure Supervision - 1 No l. Triping Relays (3AR1, 3AR2 & 3AR3) - 3 No m. Over Current HV side Unit Auxilliary Transformer CDG type - 2 No n. GT Overall Differential Protection - 1 No o. Generator Over current CDV type - 1 No p. Neutral Displacment Relay type VDG (64GX), Stator E/F - 1 No q. Auxilliary relay type VAA - 10 No r. Trip Supervision circuit type VAX - 1 No s. Auxilliary Relay Bucholz (VAA type), Oil & Winding Temp - 3 No t. Emergency Shutdown (Definite Time relay type VAT) - 1 No
Complete cleaning, testing & inspection of Electro mechanical relays installed for four numbers of 33KV outgoing feeders in LJHP power house as per standard operating procedures (SOPs) & standards and correction/ replacement is to be done, if required. The main relays installed at C&R panels are as following: a. Tripping Circuit supervision relay type VAX-03 No b. Tripping Relay type VAJ - 03 No c. Auxilliary relay type VAA - 03 No. d. Directional E/F relay IDV - 03 No. e. 3-in-1 Relay(O/C-E/F-O/C) - 03 No. f. Ashida Numerical Relay OC/EF-01 No g. Auxilliary Tripping relay-01 No.
System Protection
ETRICALS ENGINEERS PRIVATE LIMITED
Voltech Engineers Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .