Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | ₹15.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹16.5 L+₹77,385 (4.93%)Rejected-Finance PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | ₹16.5 L+₹77,385 (4.93%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹16.5 L+₹82,745 (5.27%)Rejected-Finance | ₹16.5 L+₹82,745 (5.27%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹16.5 L+₹84,420 (5.38%)Rejected-Finance 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | ₹16.5 L+₹84,420 (5.38%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹16.6 L+₹96,145 (6.13%)Rejected-Finance ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | ₹16.6 L+₹96,145 (6.13%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
30 Jul 2020, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO MAKARPURA BARODA 390014
RESOURCE MANAGEMENT FOR SEWAGE TREATMENT PLANT, RO PLANT INCLUDING BOREWELL AND SEWAGE PUMP HOUSE AT 769 SU INCLUDING MAINT OF STP AT DARJIPURA AF STN BARODA
2020_MES_359982_1
8577/E8
Open Tender
Miscellaneous Services
Item Rate
335 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹30,000
Yes
22 Aug 2020
10 Jul 2020
1 Aug 2020
10 Jul 2020
30 Jul 2020
25 Jul 2020
11 Jul 2020 - 15 Jul 2020
Amount
Resource management for sewage treatment plant installed for Md accn area at darjipura with one FGM in three shift of 08 Hrs (i.e 1st shift from 0600 hr to 1400 hr, 2nd shift from 1400 to 2200 hr and third shift from 2200 hr to 0600 hr) including sundays and holidays all as directed.
Sewage treatment plant consisting following items :-
RAW SEWAGE PUMP, Make : EDARA, of Capacity - 05 HP - 02 Nos.
Secondry clarifier mechanism with motor of capacity-02 HP - 01 No. of Make - Elecon.
AIR BLOWER MOTOR of Capacity - 2 ABB - 02 Nos.of Make :- EVEREST.
FILTER FEED PUMP of Make - Kirloskar.- 02 Nos.
TREATED WATER PUMP - 02 Nos. of Make - Kirloskar.
DG Set Complete of Capacity - 35 KVA of Make - Kirloskar.- 01 No.
Main pannel board consisting of the following :
200 Amps change over switch 4 poles on load type
MCCB 4 Pole 415 volts cap-100 Amps -03 Nos
Voltmeter,Ammeter -01 Nos each
indicating lamps-01 set
Necessary inventatory shall be taken both the parties at the commencement of work and completion of work with regard to fittings and fixtures in the sub station.
Resource management for Reverse Osmosis Plant and borewell with two FGM (one FGM in each shift) including sundays and holidays all as directed by Engr-In-Charge.
1st shift - 0600h to 1400h
2nd shift - 1400h to 2200h
RO Plant consisting of the following :-
RO plant with complete capacity 10000LPH- 01 No.
Centrifugal pump of capacity 7.5 HP - 02 Nos.
LT panel with incomer and outgoing for pumps - 01 No.
Control panel with incomer and outgoing for pumps - 01 No.
Underground sump of capacity 15000 Glns - 01 No.
PVC tank of capacity 10000 ltrs - 02 Nos.
Building with inventory and surrounding areas.
Bore well of different places with submersible pump set and starter of capacity 5 HP, 3 Phase - 04 Nos.
LT panel for each bore well at different places - 04 Nos.
GI pipe line of 80 mm dia medium grade - Approx 600 mtrs.
GI pipe line of 50 mm dia medium grade - Approx 700 mtrs.
NRV of 50 mm dia in size for 4 bore - 04 Nos.
Stop valve of 50 mm dia in size for 4 bore - 04 Nos.
Weekly cleaning/wash out of PVC tank with using bleaching powder and other suitable chemicals.
Operating the valves at spread Md Accn Area as per timing.
Bore well of different places with submersible pump set and starter of capacity 5 HP, 3 Phase - 04 Nos.
LT panel for each bore well at different places - 04 Nos.
operator will open and close the valves time to time without fail and report to concerned JE E/M and AGE E/M before and after the water supply in the area.
Valve Man/FGM liases with FGM of Main pump house and meet to concerned I/C on daily baisis for further direction.
V'Man/FGM look after the pipe line and connected items in the spread area, if any fault developed in area that time report to concerned I/C without delay for rectification the fault.
Resource management of sewage installation and pump house 769 SU area at darjipura with one FGM cum electrician in two shift 08 Hrs (i.e 1st shift from 0600 hr to 1400 hr and 2nd shift from 1400 hr to 2200 hr) including sundays and holidays all as directed.
Sewage pump house consisting following items :-
Non clog centrifugal pump set (Jyoti) of 12 HP - 02 Nos.
LT panel MCB/MCCB - 01 No.
Underground tank - 01 No.
Centrifugal monoblock pump set of 10 HP -02 Nos
Underground sump 20000 gallons - 01 Nos
Ovedr head tank of capacity 20000 gallons -01 Nos
Maintained the Bldg with inventory and surrounding areas.
Staff (all trade) shall always remain on duty and shall maintain the connected documents such as log book, Attendence register, installation running record book, water sample maintained book etc and checking daily by Engr-In-Charge.
Contractor shall provide the T & P (Spanner set) to tradesman and also provide the log sheet, Plant running book, clothing etc and all records to be maintained properly.Contractor shall maintain attendence register and shall produce on submision of RAR/Bill and as and when required duly signed by contractor, concerned JE and Engr-In-Charge.
Installation and complex should be kept clean and tidy in presentable look clearing Grass and other unwanted materials in an around the area otherwise a recovery at the double rate of quoted will be charged if the installation and its complex are not kept clean all the times.
Negligence of duty during Resource managements, maintaining of records shall be considered essential and any defeciency found during contract period same shall be viewed in the concerned and necessary compensation shall reviewd as per the contrct procedure
Contractor shall ensure that no worker shall work continuously more than 48 hrs in a week.
The electrician cum FGM shall perform any duties entrusted other than specifically mentioned in contract detailed by JE E/M or AGE E/M.
FGM cum Elect shall be ITI pass or minimum matriculate with three years experience in the trade from recognized government institution.
The trademen shall use Chemicals carefully for maintained the water quality, checking TDS & records maintained properly.
Contractor shall provide the life insurance of min 1 Lakh to all the employed manpower & copy of life insurance shall be deposited with department within one month of acceptance
No one absent on duty, if anyone found absent during the contract period, a recovery at the double rate of quoted shall be levied .
Contractors tradesman shall also be responsible for proper on/off of borewells (4 Nos) submersible pump for RO and Main pump house. Also no defficancy shall be entertainable.
Necessary documents like Attendance Register, Log Book Register, ITI Certificate for the tradesmen, proof of wage payment in the Bank, proof of EPF & ESI payment, Group Insurance etc shall be produced to the dept at the time of claiming payment without fail. No payments shall be entertained by the dept in the absence of the said documents.
K A ELECTRIC CO
Shiv Kripa Tradimg
Gayatri Associates
LAXMI CORPORATION
Dagli Engineers
Shiv Projects
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .