| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹4.4 L+₹50,000 (12.8%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹4.6 L+₹72,300 (18.6%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹6.1 L+₹2.2 L (56.8%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted |
Tender Value
₹4.0 L
EMD Value
₹8,000
Closing Date
13 Jul 2020, 6:00 pmClosed
Shri HR Sinha AEE
AF Stn Suryalanka Bapatla Guntur dst 522101
REPAIRS/REPLACEMENT OF PANELS, JUNCTION BOXES, PAINTING, NUMBERING AND ALLIED SERVICES AT CERTAIN LOCATIONS AT AF STN SURYALANKA
2020_MES_353024_1
AGE (I) / SL/ TOKEN / 23 OF 2020-21
Open Tender
Civil Works
Item Rate
240 days
AF Stn Surylanka
Please refer Tender documents.
8 documents required · 8 mandatory
₹300
AGE (I) Suryalanka
₹8,000
28 Jul 2020
15 Jun 2020
14 Jul 2020
15 Jun 2020
13 Jul 2020
29 Jun 2020
15 Jun 2020 - 22 Jun 2020
Amount
M&L for painting LT Panel of any size with one coat of red oxide and two coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparing existing old RCC electric poles and applying one coat of cement base paint blue colour and white colour 1 mtr each from ground level, numbering the poles with black colour for text & number as given with letter size not less than 5 Cm on both sides of pole complete all as sepcified and as directed. Make for Item No. 1 & 2 Asian/ Nerolac/ Berger/ Shalimar
S&F in repair 10 Sqmm PVC insulated Single Core unsheathed Industrial Flexible Cable conforming to IS 694:1990 with Flexible Bright Annealed Copper Conducotr for Voltage Grade 1100 Volts alongwith Copper lugs and fixed complete all as specificed and as directed. Make : Polycab/Nicco/Finolex/Anchor/Havells.
S&F in repair MCCB 4 pole, 100 Amps, 16 kA complete all as specified and as directed. Make : ABB/ Legrand/ Indoasian/ Havells/ Schneider.
S&F in replacement of existing loop in-out junction box with non metallic PVC junction box suitable for size 350mm x 250mm with connector 4 way and including one MCB 6 A, 230 V alongwith 2 Nos "C" clamps and back clamp made up of 20x3mm flat iron and fixing on pole with necessary nuts & botls, washers 2Nos cable glands of size not exceeding 4 core 25 Sqmm, cable lugs as required complete all as specified and as directed. Make : Sintex, Model : GSJB3525 or its equivalent in Schneider/ Hensel. Make for MCB : ABB/ Legrand/ Indoasian/ Havells/ Schneider.
S&F in replacement of existing loop in-out junction box with non metallic PVC junction box suitable for size 570mm x 280mm x 220mm for MCCB 3 pole, 100 Amps, 16 kA, with connector 4 way alongwith 2 Nos "C" clamps and back clamp made up of 20x3mm flat iron and fixing on pole with necessary nuts & botls, washers 2Nos cable glands of size not exceeding 4 core 25 Sqmm, cable lugs as required complete all as specified and as directed. Make : Sintex, Model : GSJB5728 or its equivalent in Schneider/ Hensel. Make for MCB : ABB/ Legrand/ Indoasian/ Havells/ Schneider.
S&F in replacement of LT panel outdoor, double door type made out of CRCA Sheet of 3.15mm thick with powder coated painting frame made out of angle iron 45 x 45 x6mm and four numbers of 100 Amps aluminium strips/bars duly insulated on insulators/suitable size Bakelite sheet, free space between MCB/busbar and other connection items should be provided, the space between ground to panel should be 60cm with PCC foundation for LT panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following :- (A) Main Incoming :- (i) MCCB Four Pole 40 Amps, "C" Curve, 415 V, 50 Hz-01 No, fixed thermal and megnetic setting. (ii) LED multifunctional panel meter to measure voltage, current, frequency, poder factor, kWH etc with all connected CTs. (iii) LED indicating lamps with colour Red, Yellow, Blue-01 Set. (B) Main Outgoing :- (i) MCB SP 25 Amps, 10 kA, "C" curve-03 Nos(Flood Lights, Spare) (ii) MCB DP 25 Amps, 10 kA, "C" curve - 02 Nos(for PA System) (iii) Analog Programmable Time Switch 24 Hours (SST-15 mininmum) with battery backup alongwith 4 pole contactor of 40 Amps and connector - 02 Nos.
S&F in replacement of outdoor control panel for Highmast light & Pully motor, double door type made out of CRCA Sheet of 3.15mm thick with powder coated painting frame made out of angle iron 45 x 45 x6mm and the space between ground to panel should be 60cm with PCC foundation for LT panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper wires and comprising and including the following :- (A) Main Incoming :- (i) MCCB Four Pole 32 Amps, "C" Curve, 415 V, 50 Hz-01 No. (ii) LED multifunctional panel meter to measure voltage, current, frequency, poder factor, kWH etc with all connected CTs. (iii) LED indicating lamps with colour Red, Yellow, Blue-01 Set. (B) Main Outgoing :- (i) MCCB FP 16 Amps, 10 kA, "C" curve-01 No(For Lights Control) (ii) MCB TP 16 Amps, 10 kA, "C" curve - 01 No (For 3-phase motor) (iii) Analog Programmable Time Switch 24 Hours (SST-15 mininmum) with battery backup alongwith 4 pole contactor of 40 Amps and connector - 01 No. (iv) Motor rotation direction toggle switch with soft conversion, control circuit with necessary contactors and relays - 01 No.
Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor type, double door made out of CRCA Sheet of 3.15mm thick with powder coated painting frame made out of angle iron 45 x 45 x6mm and four numbers of 300 Amps aluminium strips/bars duly insulated on insulators/suitable size Bakelite sheet, free space between MCCB/busbar and other connection items should be provided, the space between ground to panel should be 60cm with PCC foundation for LT panel, LT panel should be provided with necessary locking arrangement, danger notice stickers, cable glands, internal wiring with FRLS copper wires and comprising and including the following :- Incoming :- (i) MCCB 4 pole, 125 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting - 01 No. Outgoing :- (i) MCCB 4 pole, 100 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting - 02 Nos. (ii) MCCB 4 pole, 80 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting - 02 Nos. (iii) Intelligent panel meter to measure voltage, current, frequency, power factor, kWH etc with all connected CTs. (iv) LED indicating lamps with colour Red, Yellow, Blue-01 Set.
Supply, installation, commissioning and testing of LT Change Over Switch panel with 3 Nos Aluminium busbar chambers for cable entry, outdoor type double door made out of CRCA Sheet of 3.15mm thick with powder coated painting frame made out of angle iron 45 x 45 x 6mm, the space between ground to panel should be 60 cm with PCC foundation for LT panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, internal wiring with FRLS copper flexible wires of suitable rating and comprising and including the following :- (a) On load for four pole change over switch I-O-II with advance neutral conforms to IS:13947 (Part-3), IEC:60947-3. (b) 3 Nos busbar chambers each not less than 300 x 450 x 450mm comprising 4 Nos Aluminium bus bars 80 Amps, length not less than 20 cm duly insulated on insulators/suitable size Bakelite sheet, free space between busbar and other connected items should be provided. (Make for item No-7 to 10 : Any CPRI Approved).
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 9,800.00 B/F from Ser page No. 24. NOTE: Bidder shall insert credit amount as rate Rs. 9,800.00 in Green field under Col-6. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
K VENUGOPALA SWAMY
M/s. P S REDDY
Bismi Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .