Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹33.8 L+₹1.7 L (5.28%)Rejected-Finance D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹34.6 L+₹2.5 L (7.65%)Rejected-Finance H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹35.9 L+₹3.8 L (11.9%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹37.7 L+₹5.6 L (17.4%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
26 Jun 2020, 6:00 pmClosed
GE UTILITY II VISAKHAPATNAM
GE UTILITY II 104 Area Industrial Estate Post Visakhapatnam 530007
OPERATION AND MAINT OF FIRE FIGHTING AND FRESH WATER PH AT MWC BLDG, WATER PUMPING AT KUTHAR BLOCK AND FIRE FIGHTING PH AT SMHQ BLDG INSIDE NAVAL DOCKYARD AND CERTAIN REPAIR WORKS AT THE AOR OF AGE E/M No. I OF GE (UTILITY-II) VISAKHAPATNAM
2020_MES_342719_1
8698
Open Tender
Electrical Maintenance Service
Item Rate
330 days
GE UTILITY II VISAKHAPATNAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY II VISAKHAPATNAM
₹99,000
Yes
4 Jul 2020
30 May 2020
27 Jun 2020
30 May 2020
26 Jun 2020
13 Jun 2020
Amount
Operation and maintenance of Fire fighting pump house at Sindughsoh Building at INS Satavahana round the clock in 3 shifts of 08 hours each including sundays and holidays complete all as specified and directed by Engineer-in -Charge.
Manpower :- One Skilled Operator (FGM) per shift. Shift timings:- I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs III rd shift - 2200 Hrs to 0600 Hrs
Operation and maintenance of fresh water pump house and Fire fighting pump house at MWC Building at Naval Dockyard round the clock in 3 shifts of 08 hours each including sundays and holidays complete all as specified and directed by Engineer-in -Charge.
Manpower :- One Skilled Operator (FGM) per shift. Shift timings:- I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs III rd shift - 2200 Hrs to 0600 Hrs
Operation and maintenance of fresh water pump house and Fire fighting pump house at SMHQ Building at Naval Dockyard in 2 shifts of 08 hours each including sundays and holidays complete all as specified and directed by Engineer-in -Charge.
Manpower :- One Skilled Operator (FGM) per shift. Shift timings:- I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs
Operation and maintenance of fresh water pump house at Ranjit and Kuthar block at Naval Dockyard in General shift of 08 hours each including sundays and holidays complete all as specified and directed by Engineer-in -Charge.
Manpower :- One Semi-Skilled Operator in General shift. Shift timing: 0900 Hrs to 1700 Hrs
Note for SL item No. 1 to 4: (a) Minor store items required during maintenance such as distilled water, washers, nuts, bolts, rubber gaskets & insulation tapes etc., including provision of necessary T&P at site are deemed to be included in the quoted rate. (b) The quoted is deemed to be include for maintaining log books etc., (c) Cleaning the installations area inside outside. (d) Before commencement of work the contractor shall submit the list of manpower to be employed as per requisite qualifications specified in particular specification for approval of GE duly recommended by Engineer-in- charge.
Labour only for attending break down of CI pipe pipe line bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes, CI / DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering complete all as specified and directed by Engr-in-Charge, for the following sizes:- Note 1 :- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable Pump sets for dewatering at the time of attending break down. (ii) Necessary labour/trade men for attending break down. (iii) Labour element required for fixing CI/DI/MS pipes, specials, fittings etc. Note 2 :- Earth work, Lead joints, Supply only CI pipes, specials, fittings will be measured and paid seperately under relevant items.
300 mm bore pipe
200 mm bore pipe
150 mm bore pipe
100 mm bore pipe
80 mm bore pipe
Supply only CI pipes with spigot and socket ends centrifugally cast , Class 'B' of size 300 dia.
All as per SL. Item No.6 above but of 200 mm bore
All as per SL. Item No.6 above but of 150 mm bore
All as per SL. Item No.6 above but of 100 mm bore
All as per SL. Item No.6 above but of 80 mm bore
Supply only DI K9 water supply pipe lines of size 300 mm bore with spigot and socket ends complete
All as per SL. Item No.11 above but of 200 mm bore
All as per SL. Item No.11 above but of 150 mm bore
All as per SL. Item No.11 above but of 100 mm bore
Supply only MS ERW pipe heavy grade pipe 300 mm bore MS pipe, 5.60 mm thick
All as per SL. Item No.15 above but of 200 mm bore 6.30 mm thick
All as per SL. Item No.15 above but of 150 mm bore 5.40 mm thick
All as per SL. Item No.15 above but of 100 mm bore 4.80 mm thick
All as per SL. Item No.15 above but of 80 mm bore 4.80 mm thick NOTE for SI No. 6 to 19: (i) Labour required for fixing of CI/DI/MS pipe is included in SL item No. 5.
Material and labour for run lead joint for spigot and socket pipes (CI/DI) and fittings of size 80 mm complete all as specified and directed by Engr-in-Charge.
All as per Sl. Item No.20 above but of size 100 mm bore.
All as per Sl. Item No.20 above but of size 150 mm bore.
All as per Sl. Item No.20 above but of size 200 mm bore.
All as per Sl. Item No.20 above but of size 300 mm bore.
Labour for attending GI pipe line complaints (break downs) in buildings upto fourth storey, terrace and plain area for pipe of size 20 mm to 80 mm dia including cutting and threading of pipes as per site requirement complete all as specified and directed by Engr-in-Charge. Note: GI Pipe and fittings shall be measured and paid separately under relevent items.
Labour for attending GI pipe line complaints (break downs) in buildings fifth to eigth storey including terrace for pipe of size 20 mm to 81 mm dia including cutting and threading of pipes as per site requirement including necessary scaffolding and safety measures complete all as specified and directed by Engr-in-Charge. Note: GI Pipe and fittings shall be measured and paid separately under relevent items.
All as per SI item No.26. above but nine to twelveth storey
Supply only GI tubing medium grade of following sizes Note: The Quoted rates shall be deemed to include GI sockets and GI nipple as required at site.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply & replace 100 mm dia GI tubes medium grade with all fittings fixed to wall and ceilings or laid in floors including necessary scaffolding complete all as specified and directed.
Supply and replacement of 25 mm dia high density polythene pipe (HDPE) of pressure rating 6 Kg/ Sqcm ,including making leak proof joints complete all as specified and directed by Engineer-in-Charge
All as per Sl. Item No.30 above but of size 40 mm dia
All as per Sl. Item No.30 above but of size 50 mm dia
Supply and replace 2000 litres capacity Rotational moulded polyethylene three layer water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as per site requirement as specified in SSR Part I complete all as directed
All as per Sl. Item No.33 above but of 5000 litres capacity
S&F 20 mm (outer dia) 3-layer PP-R (Polypropylene random copolymer) concealed SDR 7.4 Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings fixed to walls, ceilings etc, complete including taking down old unserviceable GI pipe all as specified and directed by Engineer-in-charge:
All as per SL item No.35 above but of size 40 mm (outer dia)
All as per SL item No.35 above but of size 50 mm (outer dia)
All as per SL item No.35 above but of size 75 mm (outer dia)
Supply and fix 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to iron pipe complete including taking down old unserviceable all as specified and directed by Engr-in-Charge.
All as per SL item No.39 above but of size 25 mm dia.
All as per SL item No.39 above but of size 40 mm dia.
All as per SL item No.39 above but of size 50 mm dia.
All as per SL item No.39 above but of size 80 mm dia.
Supply and replace PP-R (Polypropylene random copolymer) gate valve (brass insert) 25 mm dia complete all as specified and directed.
All as per SL item No.44 above but of size 40 mm (outer dia)
All as per SL item No.44 above but of size 50 mm (outer dia)
Supply and replace existing pressure guage 6" dial, 0-10 Kg rating of existing make complete all as directed by Engr-in-charge.
Supply and replace existing pressure guage 6" dial, 0-16 Kg rating of existing make complete all as directed by Engr-in-charge.
Material & Labour for painting to old painted steel surfaces of Centrifugal/ monoblock Pump sets of capacity upto 5 HP with one coat of synthetic enamel paint including cleaning, scraping foreign material and degreasing surfaces complete all as directed
All as per SL item No.49 above but pumpset of capacity 6 to 10 HP
All as per SL item No.49 above but pumpset of capacity 12.5 to 30 HP
All as per SL item No.49 above but pumpset of capacity 40 to 75 HP
All as per SL item No.49 above but pumpset of capacity 100 to 170 HP
Dismantling centrifugal/ mono block pump of capacity upto 5 HP, coupled with electric motor 3 phase 415 volt, 50 Hz from the foundation bed for repairs and including by removing the couping and foundation bolts etc, replacement of unserviceable parts i.e. impeller nut, keys, lock washer, gasket and greasing, reassembling coupling in position and reinstall the pump with necessary bolts, nuts and washers, winding with appropriate gauge of super enamelled copper wire of same gauge and same No of turns of existing make insulating winding with existing class of insulation varnishing baking up, cleaning and removing the scales complete all as specified and directed by Engr-in-Charge:- Note : CI gland cover with MS studs, bearins and CI impeller shall be measured and paid seaparately under relavent items of BOQ.
All as per SL item No.54 above but pumpset of capacity 6 to 10 HP
All as per SL item No.54 above but pumpset of capacity 12.5 to 30 HP
All as per SL item No.54 above but pumpset of capacity 40 to 75 HP
All as per SL item No.54 above but pumpset of capacity 100 to 170 HP
Supply only bearings suitable for following capacity pumps Note:- Labour for fixing the same is deemed to be included in rewinding / servicing of pumps item as above.
upto 5 HP Capacity
6 to 10 HP Capacity
12.5 to 30 HP Capacity
40 to 75 HP Capacity
100 to 170 HP Capacity
Supply only CI Gland covers with MS Studs suitable for following capacity pumps Note:- Labour for fixing the same is deemed to be included in rewinding / servicing of pumps item as above.
upto 5 HP Capacity
6 to 10 HP Capacity
12.5 to 30 HP Capacity
40 to 75 HP Capacity
100 to 170 HP Capacity
Supply only CI impeller suitable for following capacity pumps Note:- Labour for fixing the same is deemed to be included in rewinding / servicing of pumps item as above.
upto 5 HP Capacity
6 to 10 HP Capacity
12.5 to 30 HP Capacity
40 to 75 HP Capacity
100 to 170 HP Capacity
Excavation in trenches n.exc. 1.5 m wide and n. exc. 1.5 m in depth and getting out in soft / loose soil for foundation, of pipe lines etc, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and as directed.
Removing excavated soil to a distance not exc. 50 m and depositing where directed at a level not.exc. 1.5 m above the starting point complete all as specified and as directed.
AYYAPPA CONSTRUCTIONS
lakshmi Engineering Works
ESSPEE INFRAKON
SRIESWARI ENTERPRISES
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
Prasad and Suresh Constructions
Sri Surya Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .