Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAdmitted-Finance FLAT NO 02B GAMHARIA SAWARNA PALACE TATA KANDRA MAIN ROAD VILLAGE TOWN GAMHARIA CITY JAMSHEDPUR SERAIKELA KHARSAWAN JHARKHAND 832108 INDIA | SARAIKELA KHARSAWAN | JHARKHAND | 832108 | ₹15.5 L | L1 | Admitted-Finance |
| 2 | L2₹16.4 L+₹92,466.35 (5.98%)Admitted-Finance | ₹16.4 L+₹92,466.35 (5.98%) | L2 | Admitted-Finance |
| 3 | L3₹17.2 L+₹1.7 L (11.3%)Admitted-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | ₹17.2 L+₹1.7 L (11.3%) | L3 | Admitted-Finance |
| 4 | L4₹17.3 L+₹1.9 L (12.2%)Admitted-Finance | ₹17.3 L+₹1.9 L (12.2%) | L4 | Admitted-Finance |
| 5 | L5₹19.5 L+₹4.1 L (26.4%)Admitted-Finance NEW BANSBARI NH 34 PO JHALJHALIA DIST MALDA PIN 732 102 | MALDAH | WEST BENGAL | 732102 | ₹19.5 L+₹4.1 L (26.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MONDALENTERPRISE L3 | M/s EASTERN ENGINEERING L5 | SK ENTERPRISE L2 | N.A. CONSTRUCTION L4 | GEETRAJ ENGINEERING PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 4 way Havells, Enclosure (DHDLVDRWAOFO04). | 5 | Each | 7,751 ₹38,755 | 5,812 ₹29,060 | 9,500 ₹47,500 | 7,750 ₹38,750 | 5,038 ₹25,190 Lowest |
| 2.00 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator), 6 way, Double door. | 16 | Each | 2,005 ₹32,080 | 1,503 ₹24,048 | 2,050 ₹32,800 | 2,000 ₹32,000 | 1,303.25 ₹20,852 Lowest |
| 3.00Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. | ||||||||
| 3.01 | 150 A, 16 KA,TPMCCB | 2 | Each | 5,308 ₹10,616 | 3,990 ₹7,980 | 9,500 ₹19,000 | 5,300 ₹10,600 | 3,450.2 ₹6,900.4 Lowest |
| 3.02 | 125 A, 16 KA,TPMCCB | 1 | Each | 4,282 ₹4,282 | 3,211 ₹3,211 | 8,300 ₹8,300 | 4,300 ₹4,300 | 2,783.3 ₹2,783.3 Lowest |
| 3.03 | 100 A, 16 KA,TPMCCB | 5 | Each | 3,359 ₹16,795 | 2,599 ₹12,995 | 6,800 ₹34,000 | 3,350 ₹16,750 | 2,183.35 ₹10,916.75 Lowest |
| 4.00Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | ||||||||
| 4.01 | Single pole | 116 | Each | 239 ₹27,724 | 179 ₹20,764 | 245 ₹28,420 | 150 ₹17,400 Lowest | 155.35 ₹18,020.6 |
| 4.02 | Tripple pole | 2 | Each | 898 ₹1,796 | 224 ₹448 Lowest | 1,040 ₹2,080 | 800 ₹1,600 | 583.7 ₹1,167.4 |
| 5.00 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection TPN 63 A Havells. | 7 | Each | 1,498 ₹10,486 | 1,130 ₹7,910 | 2,050 ₹14,350 | 1,000 ₹7,000 | 973.7 ₹6,815.9 Lowest |
Tender Value
₹23.8 L
EMD Value
₹47,542
Closing Date
17 Aug 2026, 4:00 pmClosed
Executive Engineer
Electrical Division, Farakka Barrage Project, P.O. Farakka Barrage, Dist. Murshidabad, West Bengal, PIN 742212
As per tender document
2026_FBPF_921077_1
GM/FBP-02 of 2026-27
Open Tender
Electrical Works
Item Rate
120 days
Farakka, Dist. Murshidabad
As per tender document
2 documents required · 2 mandatory
₹0
₹47,542
Yes
1 Sept 2026
7 Aug 2026
18 Aug 2026
7 Aug 2026
17 Aug 2026
7 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 4 way Havells, Enclosure (DHDLVDRWAOFO04). | 5 | Each | - | - |
| 2 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator), 6 way, Double door. | 16 | Each | - | - |
| 3Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. | |||||
| 3.01 | 150 A, 16 KA,TPMCCB | 2 | Each | - | - |
| 3.02 | 125 A, 16 KA,TPMCCB | 1 | Each | - | - |
| 3.03 | 100 A, 16 KA,TPMCCB | 5 | Each | - | - |
| 4Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||||
| 4.01 | Single pole | 116 | Each | - | - |
| 4.02 | Tripple pole | 2 | Each | - | - |
| 5 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection TPN 63 A Havells. | 7 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.12 MB
BOQ_967945.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .