| 1 | L1₹48.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹54.1 L+₹4.7 L (9.52%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹66.2 L+₹16.8 L (34.0%)Rejected-Finance PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹58.3 L
EMD Value
₹1.1 L
Closing Date
27 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVADA ROAD BHUJ 370001
RESTORATION OF EXTERNAL ELECTRICAL SUPPLY AT AF STN NALIYA
2023_MES_615106_1
85248/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
NALIYA
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) NALIYA
₹1.1 L
Yes
30 Oct 2023
23 Aug 2023
29 Sept 2023
24 Aug 2023
27 Sept 2023
13 Sept 2023
Amount
Excavation in trenches exceeding 1.5m wide and not exceeding1.5m in depth and getting out in soft/loose soil etc complete all as specified. Note :Serviceable PCC /RCC cable cover obtained during excavation shall be stacked separately carefully without any extra cost to the Deptt.
Returing , filling in cluding spreading leveling water and ramming layers not exceeding 25cm thick each complete and directed
Removing excavated surplus soil to a distancenot exceeding 50mtr and deposting where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified
S & F in repairPVC insulator copper wire 1100 volts grade PVC unsheathed cable multi standed copper conductor cable of 1.5 sqmm 3 core complete all as specified
S & F in repair kiosk box for luminaries weather proof mad out of PVC/HDPE/FRP housing fire retardant non fusing shock and rust proof single pice moulded and cover with hing door pole mounting comprising of aluminium TPN bus bar of 60Amps including MCB SP 6 Amps of min size 300x250x150mm fix on pole with MS clamp 30x5mm with necessary nuts washer complete all as directed
S & F prestressed concrete pole 9.0 meters long, 102x172mm at top and 102x279 mm at bottom, class 10 complete inculding taking old concrate pole/ strat of any size .
M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCCpoles/struts as specified including necessary form work all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of stay assembly etc including necessary form work , all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.
S & F in repair LED street light fitting 60 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver , including suitable size GI bracket socket with impact and corrosion resistant including thermal management in optics complete with IP 65/66 protection complete all as specified and directed by EIC.
S &F in repair LED flood light fitting 120Watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver , including suitable size GI bracket socket with impact and corrosion resistant including thermal management in optics complete with IP 65/66 protection complete all as specified and directed by EIC
S & F in repair air termination rod single point copper rod 12mm dia and 300mm long complete all as specified
S & F in repair GI pipe of dia 25 mm 1.5 RM long Light grade vertically fixed by means of PCC 1:2:4 of size 2x2x1.5 Cubic Feet for mounting of Copper air termination rod including fabrication work for mounting insulators on GI Pipe all as directed
S & F in repair test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw all as specified and directed
S & F in repair copper strip 20 x 3.15 mm fixed with saddles insulator and screws etc for roof conductor and down conductor above ground including breazing at joints complete all as directed
S & F in repair copper strip 32 x 6 mm fixed with saddles insulator and screws etc for roof conductor and down conductor above ground including breazing at joints complete all as directed
M & L for Earthing of complete with copper plate electrode 60cm x 60cmx 3.15 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to 20x3mm copper strip (upto 7.5m long) by means of bolts, nuts, check nuts and washer of copper all as shown in electrical plate No.5 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed including taking down old U/S earthing.(Note: Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM)
M & Lin repair for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.5 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed including taking down old U/S earthing.(Note: Unit rate of earthing deemed to be included with GI wire 4 mm, GI pipe light grade protection pipe 15 mm up to 7.5 RM)
M&L for providing ACSR overhead lines on LT PCC poles/steel tubular poles with aluminium conductor steel reinforced including straining properly on insulators and binding with aluminium binding wire complete, all as specified including taking down old U/S ACSR.
M&L in repair for chemical earthing complete with Copper earth plate electrode 90cmx60cm x 5 mm thick buried directly in ground vertically to depth not less than 3.00 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including Copper strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of brazing etc of copper including provn of GI protection pipe light grade of 40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore medium grade, wire mesh and lugs, test point including salt(150Kg Approx), Coal(100Kg Approx) & Magnesium sulphate(150 Kg Approx) including returning filling with cultivated soil from near by source etc. complete.Note: copper strip exceeding 7.5m long shall be measured & paid separately.The earth resistance value less than 1 ohm.Failing to achieve the value the contractor shall be re do the earthing without any extra cost.
M&L in repair LT line PVC Spacers(strip type) for two wire
M&L in repair LT line PVC Spacers(strip type) for five wire
S&F in repair pin type, porcelain, vitreous white/ brown insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 1100 volts grade complete all as directed
S&F in repair shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts; 75mm height, 90mm dia for 1100 volts grade complete all as directed
S & F in repair stay assembly complete comprising of MS galvanized stay plate 23cm x 23cm x 6mm , MS galvanised stay rod 20 mm dia with nut 215 cm long , MS galvanised stay bow 40cm long with 2 Nos galvanized thimbles with and including all fittings all as specified in SSR Part I. (Excavation , PCC for foundation, loop type insulator to be measured and paid seperately).
S&F in repair MS galvanised stay wire stranded size 7/3.15mm complete.
S&F in repair Insulator loop type porcelain vitreous, white brown or green with overall dimensions of 90x140mm clearenace of hole 25.5mm complete all as specified.
M&L galvanised steel wire 4mm dia for contineous earth wire and for guarding and cradles including binding as required with binding wire complete including taking down old GI wire, all as specified and directed ( Eye hooks to be measured and paid for seperately ).
Supply, fabricating , fixing structural mild steel channel, angle iron,flat iron and brackets, etc for fabrications of cross arms, bracings, supports, D-clamps, stiffeners,eye hooks, bolts,pole clamps and back plates including nuts, bolts and washers, welding banding cold , or hot drilling holes for insulators bolts in any shape or size as indicated or directed and `H` beam of min size 152 x152 mm of min 9 mtrs long as a pole for making over head bus etc and inclusive of one red oxide primer coat ,one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Demolition of existing damaged Earth pit and new earth pit chamber of size 30cmx30cmx30cm constructed in PCC (1:2:4) type B1 using 20mm gazed aggregate including cast iron frame with hinged pit cover of size 12'x12'having 7kg weight all as electrical plate as directed
M & L for river sand filling in trenches/ ducts 15 cm above cable and 8 cm under the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed at site.
Supply & laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over under cable for protection.
M& L for cutting under the road /pavement /hard standing or in any other situation with the manual labour for crossing of U/G cable through it and making both the end good complete all as specified and directed .
S&F in repair GI water tubing of 40 mm bore, light grade, IS-1239 marked with all fittings IS marked and laid in trenches under roads/in drains, fixed to poles/walls with suitable size flat iron/GI clamps, bolts, nuts and washers etc for cable protection, complete all as specified and as directed.
M&L for Welding of panel doors , preparing old painted surface of LT Panel board of any size by thoroughly cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes, using wire brush or sand papers, damp cloth or as directed. Priming the surface with anti corrosive primers using suitable sprayers. Applying automotive paint using sprayers till glossy finish is obtained, complete all as per manufacturers instructions and as directed. Note - The numbers of hinges fixed in one panel and welding will be considered in one job.
Supply and laying, testing and commissioning of XLPE insulated, armoured, heavy duty electric cable multi stranded aluminum conductors, 1100V grade, of size 16 Sqmm 4 core with proper size of lugs and laid in trenches / ducts / through GI pipe / fixed to poles etc complete all as specified and directed by Engr-in-Charge. Note: Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately under relevant item.
All as per item No 41 above but of size 25 Sqmm 4 core
Taking out old unserviceable LT cable of any size any type from trench/duct/poles/ roof/pipe etc and keeping aside for segregation of serviceability.
M/s SK Traders
KALIKAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .