Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC 03 NEW TRIMURTI CO OP HSG SOCIETY WARDHA ROAD NAGPUR 440005 | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.5 L+₹7.6 L (109.8%)Rejected-Finance 206 MADHUKALA BHAVAN R K VAIDYA ROAD DADAR MUMBAI MAHARASHTRA 400028 | MUMBAI | MAHARASHTRA | 400028 | L2 | Rejected-Finance L2 | |
| 3 | L3₹15.5 L+₹8.6 L (124.4%)Rejected-Finance B 248 BASEMENT BLOCK B CHITTARANJAN PARK NEW DELHI 110019 11 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | L3 | Rejected-Finance L3 | |
| 4 | L4₹18.5 L+₹11.6 L (168.1%)Rejected-Finance A 8 MOHAN CO OPERATIVE INDUSTRIAL ESTATE MATHURA ROAD NEW DELHI 110044 INDIA | NEW DELHI | NEW DELHI | DELHI | 110044 | L4 | Rejected-Finance L4 | |
| 5 | L5₹18.7 L+₹11.8 L (170.7%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
1 Dec 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CM (ES and E)
Indian Institute of Management Ahmedabad
Tender for non distractive testing of faculty block building at IIMA
2020_IIMA_595667_1
IIMA/Contracts/TS-040/2020-21
Open Tender
Survey and Investigation services
Works
30 days
Indian Institute of Management Ahmedabad
As per NIT
4 documents required · 4 mandatory
₹0
₹20,000
Indian Institute of Management Ahmedabad
6 May 2022
6 Nov 2020
2 Dec 2020
6 Nov 2020
1 Dec 2020
13 Nov 2020
6 Nov 2020 - 11 Nov 2020
11 Nov 2020
180 days
Amount
Double Flat jack test – For assessing the in-situ compressive strength of masonry: Performing in situ double flat jack test method for determining the deformation properties of existing unreinforced solid-unit masonry as per ASTM - C1197-04 or RILEM - MDT. D.5 standards, including detection of reinforcement either by rebar locators or by GPR at test locations, making slots in walls, inserting two flat jacks in the wall slots along with necessary shims, presurring the flat jacks with hydraulick pressure so as to indude compressive stress on the masonry wall. The flat jack shall be calibrated as per procedure laid down in ASTM. Calculating and reporting compressive stress.
Walls & Piers - With Load / Stress cal- culations
Ultrasonic Pulse Velocity test + Rebound Hammer test: (i) Ultrasonic Pulse Velocity Test: Conducting Ultrasonic Pulse Velocity Test by Direct / Semi-Direct / Indirect method as required as per IS 516(Part 5/Sec 1), removing of plaster at test location, marking the points, including making surface smooth by grinding, applying suitable coupling agents. Machine shall be calibrated with calibration rod or by making zero adjustment on the machine before taking site readings. Applying appropriate correction factors for temperature, moisture, stress ( if core testing is carried out along with UPV test ), reinforcement etc. ; including all lead, lift, transportation but without scaffolding & de-watering etc. etc. complete. The report shall include data of site conditions , concrete mix, UP Velocity in Km/Sec., quality of concrete and predicted compressive strength for every reading. (ii) Rebound Hammer Test: Conducting Rebound Hammer test on concrete including marking of points, removing of plaster/tiles/water proofing at test location, making concrete surface smooth by grinding if required. The final rebound number reading of the location shall comprise of average of minimum nine readings. The rebound hammer shall have Anvil calibration reading marked on the hammer with calibration date, including all lead, lift, transportation but without scaffolding & de-watering etc. complete. Reference IS code – 13311(2) / IS 516(Part 5/Sec 2). The report shall include data of site conditions , concrete mix, average rebound number and predicted compressive strength in combination with UPV test for every reading.
RCC Beams / Lintel Beams ( Direct / Sem-Direct Method)
RCC Beams / Lintel Beams (In-Direct Method) for Crack depth measurement ( Crack and reference nos will be measured separately)
Diamond Core cutting of concrete with surface treatment, compression testing: Extracting concrete cores of various diameter from the RCC / PCC by diamond core drilling machine. The reinforcement shall be detected before cutting concrete and as far as possible reinforcement shall be avoided in the core. The core diameter to length ratio shall be normally between 1.0 to 2.0 (preferably 2.0) the core diameter shall be at least three times the nominal maximum size of aggregate. The both ends of cylindrical concrete cores to be made smooth and flat by cutting the core ends with diamond blades or grinding. Alternatively cores may be capped with suitable material. Cap shall be as thin as practicable. The strength of capping material shall be higher than that of concrete in the core. The specimen shall be cured in water for 40 hours before testing, and then testing for compressive strength with controlled rate of loading as per IS code, including all lead, lift, transportation but without scaffolding & de-watering etc. complete. The report shall include information such as Dia. of core, height of core, H/D ratio, Correction factor for H / D, Correction factor for Diameter, True Crushing Load, Compressive Strength of core cylinder, Equivalent Cube strength. Ref code - IS 516 ( Part 4)
75 / 100 mm Dia -RCC Members
Diamond Core cutting of Brick Masonry, including detection of reinforcement before cutting concrete either by rebar locators or by GPR at test locations and as far as possible reinforcement shall be avoided in the core.
100 mm Dia - Extracted Vertically or Horizontally
150 mm Dia - Extracted Vertically or Horizontally
Grouting core holes in concrete: Grouting of the core holes up to 100 mm dia. either with cementitious polymer modified non-shrink grout materials or with non-shrink epoxy grouts, having 28 days compressive strength of at least 25 N/Sqmm. or one grade above the parent grade of concrete, including cleaning the hole, applying epoxy-latex bond coat to the inner surface of the hole, packing the grout material, applying fast setting cement over the filled up grout surface, applying coat of curing compound covering entire grouted surface; including all lead, lift, transportation but without scaffolding & de-watering etc. complete.
Compression testing of Masonry cores with surface treatment and report
100 mm Dia / 150 mm Dia - Tested Vertically . The both ends of cylindrical concrete cores to be made smooth and flat by cutting the core ends with diamond blades or grinding. Alternatively cores may be capped with suitable material. Cap shall be as thin as practicable. The strength of capping material shall be higher than that of concrete in the core.
150 mm Dia - Tested Horizontally (as per UIC 778-3R -11) with Semi circular top and bottom plates, Testing extracted Cores of 150 mm diameter in Horizontal position.( For testing in horizontal position the special shape half-round top and bottom plates shall be used) including submission test report etc.
Half-Cell Potential Test - For Corrosion Mapping: Conducting Half-Cell potentiometer test as per ASTM – C – 876 by Copper- Copper sulphate cell, for assessing the probability of the corrosion activity in RCC Member. Opening of reinforcement at one point to connect the one end of voltmeter to reinforcement. If concrete is dry and if readings are not stable it shall be made wet either by spraying or wetting the member with pre-wetting solution as per ASTM – C – 876. For Column & beams readings ( test points ) shall be taken at every 500 mm c/c and that for slab, walls readings shall be taken on grid of 1000 x 1000 mm.; including removing of plaster at test location, at all lead, lift, transportation but without scaffolding & de-watering etc. complete. The test report shall include data about temperature, pre-wetting condition, equi-potential contour maps.
RCC Beams / Lintel Beams
RCC Slabs
Reinforced Brick walls
Reinforced Brick Pillars
Carbonation Test on RCC Core samples including cover measurement: Measurement of depth of carbonation by spraying Phenolphthalein 1% indicator solution, on extracted concrete core samples, the concrete which turns colourless is treated as carbonated concrete and the concrete which turn into pink colour is treated as uncarbonated concrete. At the same location the cover depth over reinforcement is also to be measured by Rebar locators; including all lead, lift, transportation but without scaffolding & de-watering etc. complete.
Sulphate & Chloride Content in Concrete Core samples: The Total water-soluble Sulphate content of the concrete mix, expressed as SO3, by mass of the cement in the mix. As per IS 456 - 2000, Maximum Total Acid Soluble Chloride Content expressed as (Kg / m3) of concrete.
Detection of reinforcement in Brick wall by GPR: Detection of reinforcement in Brick wall by Ground Penetrarting radar method upto a depth of about 300 mm for a grid size as specified belwo at each location, including marking the position of rebars on the wall itself and preparting the report of reinforcement mapping showing the mapped rebars. Detection of first layer of reinforcement from the detection face is sufficient
For Brick walls - Grid size 2 x 2 m
For Brick Pier - Grid size 1 x 2 m
Epicons Consultants Pvt Ltd
Cortex Construction Solutions Pvt Ltd
AIMIL LIMITED
Construction Diagnostic Centre Pvt. Ltd.
Bureau Veritas (India) Pvt. Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .