| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC | ₹5.6 L Quoted ₹5.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹6.3 L+₹49,340 (8.56%)Rejected-Finance | ₹6.3 L+₹49,340 (8.56%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹9.0 L+₹3.2 L (56.1%)Rejected-Finance | ₹9.0 L+₹3.2 L (56.1%) | L3 | Rejected-Finance Being L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical bidder does not meet eligibility criteria |
| Sl No | Description | Qty | Unit | zotabrothers L2 | PURAN CHANDRA BHATT & SONS L1 | MAA PUNAGRI ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down unserviceable LED light fittings of any watt and type from existing position pole / wall/ tower, complete for and including repair and re-fixing in existing position after repair complete all as specified and as directed.
Note:
(i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as ‘Supply only’ under relavent item here-in-after.
ii) Labour cost for replacing spare parts,removing unserviceable parts, dismantling light fitting and refixing are deemed to be included in the quoted rate. | 20 | EACH | 150 ₹3,000 Lowest | 200 ₹4,000 | 200 ₹4,000 |
| 2.00 | Supply only oudoor drivers Out door type drivers suitable for 70 watts LED lights for flood lights/post top latern lights/street light/security lights including necessary connecting arrangements as per site requirement complete all as specified and as directed.
Make : Philips/Wipro/Surya/Crompton. | 10 | EACH | 1,200 ₹12,000 Lowest | 1,700 ₹17,000 | 1,690 ₹16,900 |
| 3.00 | All as per item here-in-before but Out door type drivers suitable for 35/40 watts LED lights complete all as specified and as directed. | 10 | EACH | 800 ₹8,000 Lowest | 1,300 ₹13,000 | 1,355 ₹13,550 |
| 4.00 | Supply, Fixing and Testing LED street light luminaire fitting of not less than 70 Watt,Luminaire fitting of IP65/ 66 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 5 KV complete and making good disturbed surfaces complete all as specified and as directed.
Make : Surya / Philips/ Bajaj /Crompton. | 15 | EACH | 2,200 ₹33,000 Lowest | 5,700 ₹85,500 | 4,350 ₹65,250 |
| 5.00 | PCC for coping for Light pole, road cutting etc whereever necessary 1:3:6 type C-1 (20 mm graded aggregate) complete all as specified and directed. | 1 | CUBIC METRE | 4,000 ₹4,000 Lowest | 8,000 ₹8,000 | 7,500 ₹7,500 |
| 6.00 | M&L for tubes light grade galvanised iron pipes of 40 mm sizes with all fittings and fixed under road / culvert/cable protection , complete all as specified and directed. | 18 | RUNNING METRE | 400 ₹7,200 | 350 ₹6,300 Lowest | 395 ₹7,110 |
| 7.00 | Taking down old unservicaeble security light pole junction box/bus bar box etc from existing security light poles / wall from existing positions including disconnecting existing cable connections carefully and MS clamps etc complete all as specified and directed. | 10 | EACH | 400 ₹4,000 | 65 ₹650 Lowest | 90 ₹900 |
| 8.00 | Supply, Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 55 fabricated by CPRI certified panel manufacturer's and including suitable terminal TPN 10 KA SMC Connector, MCB SP 20 Amps 'C' curve - 01 No , hinged door with Two hinges, Locking system - 01 No for fixing as per site and including MS Clamps - 02 Nos of suitable shape of size 25mm width, 6 mm thick, 900mm long for steel tublar pole with zinc coated nut, bolts and washers as per site requirement complete all as specified and directed. | 10 | EACH | 2,500 ₹25,000 | 1,400 ₹14,000 Lowest | 3,250 ₹32,500 |
| 9.00 | Material and labour for removing of existing loop cable from under ground, after rectificattion of fault /damaged cable portion and rearrange the cable to same existing location with proper connections including lugs, nuts, bolts including Earth work etc, complete all as specified and as directed. | 5 | EACH JOB | 400 ₹2,000 | 300 ₹1,500 Lowest | 550 ₹2,750 |
| 10.00 | Material and labour for cutting of bituminous road/ floor for laying of pipe / cables n. exc 1.5m wide and n. exc 1.5m deep including refilling with material and watering well ramming compacting and making good with PCC 1:3:6 type B1 suitable thick complete all as specified and directed. Note: PCC shall measured and paid separately under relevant itemof schedule. | 5 | EACH JOB | 700 ₹3,500 | 150 ₹750 Lowest | 850 ₹4,250 |
Tender Value
₹5.8 L
EMD Value
₹12,000
Closing Date
1 Aug 2026, 6:00 pmClosed
GE (I) (CG) Gandhinagar
GE (I) (CG) Gandhinagar, G-252, Sector-09, Gandhinagar-382007
REPAIRS / MAINT OF HT / LT ELECTRIC CABLE, POLES, TRANSFORMER, PANEL ETC AND REPAIRS / MAINT OF EXTERNAL WATER SUPPLY PIPE LINE, VALVES, PUMP, MOTOR, RO PLANT FILTER MEDIA, STP WITH MISC ALLIED WORKS AT ICGS MUNDRA UNDER GE (I) (CG) GANDHINAGAR
2026_MES_758504_3
8198/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ICGS Mundra
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) CG Gandhinagar
₹12,000
Yes
5 Sept 2026
27 Jun 2026
3 Aug 2026
27 Jun 2026
1 Aug 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 5 | PCC for coping for Light pole, road cutting etc whereever necessary 1:3:6 type C-1 (20 mm graded aggregate) complete all as specified and directed. | 1 | CUBIC METRE | - | - |
| 6 | M&L for tubes light grade galvanised iron pipes of 40 mm sizes with all fittings and fixed under road / culvert/cable protection , complete all as specified and directed. | 18 | RUNNING METRE | - | - |
| 7 | Taking down old unservicaeble security light pole junction box/bus bar box etc from existing security light poles / wall from existing positions including disconnecting existing cable connections carefully and MS clamps etc complete all as specified and directed. | 10 | EACH | - | - |
| 8 | Supply, Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 55 fabricated by CPRI certified panel manufacturer's and including suitable terminal TPN 10 KA SMC Connector, MCB SP 20 Amps 'C' curve - 01 No , hinged door with Two hinges, Locking system - 01 No for fixing as per site and including MS Clamps - 02 Nos of suitable shape of size 25mm width, 6 mm thick, 900mm long for steel tublar pole with zinc coated nut, bolts and washers as per site requirement complete all as specified and directed. | 10 | EACH | - | - |
| 9 | Material and labour for removing of existing loop cable from under ground, after rectificattion of fault /damaged cable portion and rearrange the cable to same existing location with proper connections including lugs, nuts, bolts including Earth work etc, complete all as specified and as directed. | 5 | EACH JOB | - | - |
| 11 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core solid conductor nominal cross section in service connection complete all as specified and directed. | 100 | RUNNING METRE | - | - |
| 12 | Supply, laying of 16 sqmm 4 core of cable XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor , connecting with proper size Aluminium lugs, glands whereever necessary near LT Panels / Bus bar chamber panel / Street light boxes all as per site requirement , testing complete all as specified and directed. | 180 | RUNNING METRE | - | - |
| 13 | Excavation in trenches n. exc 1.5 m deep and n. exc 1.5 m in depth for taking up / laying cable etc incl for each additional 1.5m or part thereof in depth beyond the first 1.5 and getting out for soft/loose soil complete all as specified and directed. | 46 | CUBIC METRE | - | - |
| 14 | M&L for sand filling in trenches with clean dry sand unwashed including gently pruning around cables complete all as specified and directed. | 14 | CUBIC METRE | - | - |
| 15 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type-2. flat size 250 mm x 150 mm x 40 mm thick, concrete grade M-20 minimum, complete all as specified and directed. | 980 | EACH | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_867940.xls
BOQ • 0.32 MB
8198ps.pdf
Tender Documents • 0.84 MB
amdt002.pdf
PDF • 0.19 MB
amdt02.pdf
PDF • 0.19 MB
amdt.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .