Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹34.7 L+₹1.9 L (5.68%)Rejected-Finance | L2 | Rejected-Finance HIGHER RATE |
Tender Value
₹31.1 L
EMD Value
₹62,100
Closing Date
11 Oct 2024, 6:00 pmClosed
GE ARMY BHUJ
BHUJ
CERTAIN MISC ESSENTIAL REPAIR OF BLDGS AND REPAIR REPLACEMENT OF WATER SUPPLY LINE OF SIYOT UNDER AGE BR II AND AGE EM OF GE ARMY BHUJ
2024_MES_670879_1
8236
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹62,100
Yes
13 Nov 2024
3 Sept 2024
14 Oct 2024
3 Sept 2024
11 Oct 2024
16 Sept 2024
Amount
Taking out liquid sludge including floating sludge contents from septic tank of any description and in any position and cleaning septic tank up to bottom including walls at any depth from ground level by pumping through sewage disposal pump / honey sucker pump ( as directed by the Engr-in-charge and as on required basis) and removing the liquid sludge outside of the MD land or nearer manhole of civil sewage line in such a manner that there shall be no nuisance and no unhygienic environment complete all as specified and directed. Note: Pump , honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Deptt.
Dewatering complete filter bed of 200 to 300 user capacity of any description and in any position, by pumping through sewage disposal pump/ honey sucker pump (as directed by Engr-in-charge and as on required basis) upto bottom / bed outlet of dewatering at least 10m away (as and when enquired) completed all as specified and directed.
Taking out sedimented sludge left out after taking out and removing liquid sludge/effluent , from septic tank of any description, in any position and of any depth, removing the sludge depositions as directed, cleaning septic tank up to bottom, including walls and removing and disposal of the sedimented/solid sludge at any depth to a distance of n.exc 250 mtr distance and burying in ground complete all as specified and directed. Note: Pump , honey sucker pump and sludge removal van / vehicles shall be arranged by contractor at his own cost and nothing extra shall be governed by the Depth.
Cleaning of existing chocked/ blocked sewage lines of 150mm bore, of any description and in any position by taking out loose sediment sand, girt, ash, sludge water, rags, fibre or vegetation from the sewage line to any depth from GL including removal of sludge/debris outside of MD L and in such a manner that there shall be no nuisance and no unhygienic environment at the place of disposal complete all as specified and directed.
Cleaning of existing chocked/ blocked sewage lines of 200mm bore, of any description and in any position by taking out loose sediment sand, girt, ash, sludge water, rags, fibre or vegetation from the sewage line to any depth from GL including removal of sludge/debris outside of MD L and in such a manner that there shall be no nuisance and no unhygienic environment at the place of disposal complete all as specified and directed.
Opening and cleaning of blockage of kitchen/bath traps or WC any pattern and in any position by rodding, manually or mechanically upto 1st manholes as on required basis complete all as specified and directed.
Cleaning of blocked manhole of any description and in any position depth n exc 1.5 m deep mechanically or manually by taking off sludge waste /night soil and silted soil from the existing manhole of any size collecting and removal of sludge in sealed container out of the cantonment area in such a manner that there shall be no nuisance and no unhygienic environment at the places of disposal area complete all as specified and directed.
Cleaning of blocked manhole of any description and in any position depth exc 1.5 m but n exc 3m deep mechanically or manually by taking off sludge waste /night soil and silted soil from the existing manhole of any size collecting and removal of sludge in sealed container out of the cantonment area in such a manner that there shall be no nuisance and no unhygienic environment at the places of disposal area complete all as specified and directed.
Excavation in trenches n.exc. 1.5m wide and n.exc 1.5 m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10sqm on plan and n 'exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Excavation in trenches n.exc. 1.5m wide and exc 1.5 m & n exc 3m in depth for foundation for laying /taking down sewage / water supply lines , forming bottom surfaces to required slope & gradient and n.exc 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),200 mm dia pipe of any description and in any position set and jointed in cement mortar complete all as specified and directed.
M&L for concrete bed to drain pipes in cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) including packing under, and haunching against the side of the pipes after they are laid tested for pipes of 200mm dia complete all as specified and directed.
S&F jointing and testing for reinforced concrete drain pipes, 200mm bore, class NP-2, laid and jointed with collar in CM (1:1) completed all as specified and directed.
Demolition of pre-cast concrete block masonry built in cement mortar of any description in any position completed all as specified and directed.
M&L for precast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete Type B-1, 1:5:10 (20mm graded aggregate and 12.50 mm in the ratio completed all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on concrete/ fair surfaces of block masonry, finished even and smooth without using extra cement with and including mixing water proofing compound as per manufacturers instructions complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid for separately under appropriate item of Sch "A' as supply only on requirement basis
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping exposed surfaces finished even and smooth using extra cement including necessary form work complete all as specified and directed.
Demolition of RCC manholes covers of any description and in any position complete all as specified and directed.
M & L for pre-cast cement concrete 1:2:4 type B1 (using 20 mm graded aggregate) for manholes covers including placing in position and set in cement mortar (1:4) complete all as specified and directed.
M & L for TMT 10mm dia and over as in reinforcement cut to length bent to shape required including cranking etc and binding with MS wire (annealed) not less than 0.9mm dia complete all as directed.
Returning ,filling in including spreading levelling watering and well ramming in layers not exc 25cm thick in soil in any depth complete all as specified and directed.
Removing excavated soil/ materials to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as directed.
Demolition of concrete (unreinforced) of any description and in any position not specifically provided completed all as specified and directed.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation of manholes, mass concrete etc. complete all as directed.
M & L for Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1) smooth finished, and reforming benching as required for 225 mm dia of pipe completed all as specified and directed.
Supply only water proofing compound all as specified and directed completed all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises completed all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for glazed ceramic tiles, coloured tiles, 450X300 x 7mm thick on vertical faces i.e.. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 10 mm thick backing coat in cement mortar (1:4) complete all as specified and directed.
S & F in repair vitreous china wash basin, white flat back , size 550mmx450mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated fancy type pillar tap 15mm bore, screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed.
S&F in repair vitreous china Wash down water closet (pedestal pattern), complete including Pedestal pan and trap and seat cover, including connection to drain ( or outgoing pipe) and flushing pipe, antisyphonage pipes etc (excluding flushing cistern and flush pipe) completed all as specified and directed.
S&F in repair vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white with integral foot rests and connection with cast iron P trap and to flushing pipe, anti syphonage pipe etc (excluding flushing cistern and flush pipe) complete with provision of lime concrete bedding including taking down/ Dismantling existing unserviceable WC of any description and in any position & fixing new WC in repair and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S&F in repair PVC valve-less, syphonic action type, flushing cistern, low level, 10 litre capacity (ISI marked) white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F in repair Pillar taps cast copper alloy quarter turn, fancy type CP screwed down high pressure for 15mm bore complete all as specified and directed.
S&F PVC waste pipe for 32mm bore pipe complete complete all as specified and directed.
S&F in repair Bib taps CP fancy type with butterfly handle screwed down high pressure for 15mm bore ISI marked complete all as specified and directed .
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over 20mm thick screed layer in cement mortar 1:6 and pointed in white cement with pigment to match with colour of tile complete all as specified and directed.
Dismantling of Chainlink wire fencing of any description and in any position complete all as specified and directed.
Dismantling posts or struts (wood, steel or RCC) any section incl taking out embedded portion and making good disturbed ground (post embedded in natural ground) complete all as specified and directed.
Excavating in Soft/loose soil post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc. 50 m and making good surface complete all as specified and directed.
Excavating in soft/disintegrated rock post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc. 50 m and making good surface complete all as specified and directed.
M & L for PCC 1:2:4 type B2 (using 40mm graded trap stone aggregate ) as in foundation complete all as specified and directed.
S & F of Framed works for chain links angles, frame work for watertanks including etc conforming to Fe-290.Gde-E-165 complete all as specified and directed.
M & L for round bars 10mm dia and over cut to length, bent to shape including cranking, binding spirally for hooping for columns hooking ends and binding with end including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Supply only chain link mild steel galvanized fencing of mesh size 75 x 75 mm & nominal dia of mesh wire not less than 3 mm complete all as specified and directed.
Fixing only chain link fencing including line wire, any mesh size and type to any type of standard rails, straining bolt etc complete all as specified and directed.
Supply only mild steel flat iron of Fe-410-0 or Fe-310-0 in required length for fixing/supporting to chain link fencing and post complete all as specified and directed.
S & F mild steel (5 to 10mm dia of neck) screw bolt (machine made) exc 5cm but not exc 10 cm in length with hexagonal or square head at one end and screwed the other each screw end to be fitted with washer 3 mm thick mild steel complete all as specified and directed.
S&F of Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) and paid seperatly complete all as specified and directed.
M&L Preparation of new steel surface of anydescrition n exc 10 cm width or girth when unconnected with other painting or when painted indifferent tint complete all as specified and directed.
M&L Preparation of new steel surface exc 10 cm width and girth and applying two coat of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed.
Site Clearance and cutting to shurbs, vegetation etc and disposal of rubbish up to a distance of 50m outside the periphery of area complete all as specified and directed.
Supply & fix rolled mild steel in joist, angle ,channel as in purlins, rafters cleats etc conforming to Fe-410- W (Gde-E-250)quality A complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge / roof covering/ cladding to wall, fixed with self tapping screws as specified all as specified and as directed.
Providing ,supplying and fixing Modular false Ceiling with USG KNAUF PVC Laminated Gypsum Tile white Sand 7 mm with aluminium foil Back 595X595 mm SQ Edge on true line Suspended with USGKNAUF Unilite GI Powder coated Plain White 32x24 mm T Grid System with all necessary accessories as per drawing and instruction on site complete all as specified and directed.
Supply and fixing LED street light fitting 90W Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing in replacement old rusted street light bracket, clamps, nuts and bolt with new street light bracket made out of 25 mm dia medium grade GI pipe (length of pipe should not be less than 2 mtrs) , two set of clamp flat iron, nuts & bolts as required , bend to shape and fixing arrangement duly welded complete all as specified and directed.
Supply and fixing in replacement old unserveceable cable junction box with new pole mounted thermoplastic cable junction box for street light with IP-65 protection, weather proof with metric knockouts for cable entry for outdoor installation with front door opening system including terminals for one incoming and two outgoing cables of size 16/25 sqmm 4 core, one MCB SP 3 to 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed .
M&L for twin core PVC insulated sheathed(heavy duty) unarmoured aluminium conductor including PVC conduit for cable (for phase and neutral) of size 2.50 Sqmm for connection drawing through pole or GI brackets of street light fittings to junction box complete all as directed.
Comprehensive maintenance of DG sets of capcity 62.5 KVA for routine/preventive maintenance, checking up of Engine and Alternator, AMF panel for smooth functioning and attending breakdowns/ complaints as and when required for smooth functioning of DG Set. The type of work/maintenance services to be carried out during comprehensive maintenance are as under:- (a) Cleaning of air filter (b) Checking and adjusting of valve tappet clearance (c) Checking of Engine lubrication system, fuel system, air system, cooling system, mechanical adjustments/rectification and electrical system. (d) Changing of lube oil filter if necessary (e) Changing/cleaning of fuel pre & fine filter (f) Checking and tightening of bolts and nuts (g) Checking of flexible rubber coupling (h) Checking of charging system of the battery. (i) Checking of ‘V’ belt and adjusting the tension (j) Checking of exhaust turbo charger (k) Checking of fuel injector (l) Checking and cleaning of breather pipe (m) Checking of alternator terminals and cable lighteners etc (n) Checking of safety controls operation (o) Checking of speed governors and engine shut down for proper functioning. (p) Checking of proper functioning of self starter and provision and battery charging (q) Greasing of generator (r) Carrying out preventive maintenance, checking as per manufacturer’s recommendations and to make proper functioning/serviceability of u/s RPM meter and hour meter and all engine parameters, gauges throughout the CA period and if required replace with new one without any extra cost.
Supply only set of fuel pre-filters and fine filters as per sample and make of the 62.5 KVA capacities of DG sets for above said capacity complete all as specified and directed.
Supply only set of lub/engine oil filters/cartridges as per sample and make, of the 62.5KVA capacities of DG sets for above said capacity complete all as specified and directed.
Supply only main contactor for AMF panel model of 62.5 KVA DG set complete all as specified and directed
Supply only micro processed based PCB for AMF panel model of 62.5 KVA DG set complete all as specified and directed.
Supply only Auxillary/control contactors (2 NO, 2 NC) of suitable ratings for AMF panels complete all as specified and directed
Supply only battery charger ie step down transformer) fo ratings 100 VA 220-240V/12-14-16 Voltssuitable for AMF panels complete all as specified and directed
Material and labour for radiator anticorrosive coolent conditioner properly mixed up with the radiator water complete all as specified and directed.
Material and labour for lubricant oil for diesel generating set of any capacity and any make complete all as specified and directed by Accepting officer
Supply only lead acid battery 12 V 150 AH, complete all as specified and directed.
Supply only battery charger ie step down transformer) fo ratings 200 VA , 415 Volts 0-18 Voltssuitable for AMF panels complete all as specified and directed
Supply and fixing in replacement of LED Bolard new generation ,energy saving, environmental friendly , long life aesthetically designed aluminum landscape for diffused lighting with high power LEDs ,IP65 protection and impact of capacity 20 Watt complete all as specified and directed.
M&L for three core PVC insulated sheathed(heavy duty) unarmoured aluminium conductor cable of size 2.50 Sqmm including PVC conduit concealing in any ground, surface , for connection drawing through pole , conduit for light fittings complete all as directed.
Dismantling of defective centrifugal pump set/open well pump set, of any make/Model for repairing and reassembling including replacement of defective spare parts by new one of capacity of 5 HP pump set including required MS stud with nuts and bolts etc all as required. Note: (i) Spare parts of the centrifugal pump sets shall be measured and paid separately under relavent item of schedule. (ii) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop with replacement of oil seal, sand guard, bolt gusket, cable packing ring, water seal, bearing bush upper & lower etc as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at authorised workshop.
M & L rewinding of induction motor after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including complete all as specified and directed at site etc. of capacity 5 HP Motor.
Supply only suitable size bearing for induction motor of 5 HP , after taking out old unservicable complete all as specified and directed at site etc.
Supply and fix in repairs RO Membranes Brakish Water Spiral (CPA3) type, capacity upto 3000 LPH, pressure 12 Kg/Sqcm, MOC Cellulose Polyamide, of Filteration grade 97-98% Salt Rejection of Size 8040 complete with pressure vessels, RO membrane connectors etc Make : Toray/LG/ Hydranautics
S&F in repair Bag filter 4" x 20", type multimedia filter, filtration grade - 5 micron, flow rate not less than 3000 Ltrs / Hr, complete as directed of make Aqualux / Ion exchange / Aqua.
Supply and fix in repairs Cartridge Filter Online wound type of size 2.5" Dia x 20" long, Pressure 3.5 - 4.0Kg/Sqcm, MOC : PP, Filteration Grade 20 Microns, capacity 2.0m3/hr complete.
Dismantling of defective centrifugal pump set of RO plant , of any make/Model for repairing and reassembling including replacement of defective spare parts by new one of capacity of 1/1.5/2 HP pump set including required MS stud with nuts and bolts etc all as required. Note: (i) Spare parts of the centrifugal pump sets shall be measured and paid separately under relavent item of schedule. (ii) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop with replacement of oil seal, sand guard, bolt gusket, cable packing ring, water seal, bearing bush upper & lower etc as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at authorised workshop.
M & L rewinding of induction motor after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including complete all as specified and directed at site etc. of capacity 1/1.5 HP Motor.
M & L rewinding of induction motor after taking out all burnt ,U/s copper winding wire, cleaning and finishing of the casing and slots properly for rewinding the motors with existing SWG super enameled copper wire including varnishing ,baking ,testing including complete all as specified and directed at site etc. of capacity 2HP Motor.
Supply only suitable size bearing for induction motor of 1/1.5/2 HP , after taking out old unservicable complete all as specified and directed at site etc.
Disconnecting and taking down old PVC tubing and connections of any description/ grade and in any position in trenches/under floors / on walls etc including all fittings/accessories and fixtures such as bends, union, elbow socket, valves, taps etc, all as directed and specified for 20 mm dia pipe complete all as specified and directed.
All as per item No. 84 here in above but 25 mm dia pipe.
All as per item No. 84 here in above but 40 mm dia pipe.
All as per item No. 84 here in above but 50 mm dia pipe.
All as per item No. 84 here in above but 80 mm dia pipe.
Supply and Fixing in any length UPVC pipe 20 mm dia pipe manufactured as per ASTM-D-1785 as per IS-559, Schedule-40 complete with fittings, laid in trenches in required length complete all as specified and directed
All as per item No. 85 here in above but size (25 mm dia).
All as per item No. 85 here in above but size (40 mm dia).
All as per item No. 85here in above but size (50 mm dia).
All as per item No. 85here in above but size (80 mm dia).
S & F in repair UPVC Ball valves with operating handle (stop valve) of size 20 mm dia complete suitable for fittings with ASTM - 1785, Schedule 40 UPVC pipes all as specified and as directed.
All as per item No. 86 here in above but of size (25 mm dia).
All as per item No. 86 here in above but of size (50 mm dia).
All as per item No. 86 here in above but of size (80 mm dia).
Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed.
Returning filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointall complete all as specified and directed.
Testing of water for physical bacteriogical analyisi as per standared/IS cod test from any govt approved recognized lab or NABL approved lab or approved by the GE sample should be collected by Ref of lab.
M&L for Dismantling the water mains from the delivery lines, lifting/taking up GI/UPVC/HDPE Column pipes, pumping sets of any description and in any position including submersible cable after disconnecting pumping sets from cable, repairs to the defective submersible cable and jointing of submersible cable, pump and motors by using water proofing jointing kit, and also jointing of crack/leaked HDPE pipe with MS sheet jointing clamp,rubber sheet, nut, bolts and washer etc replacement of defective column pipes, and including Lowering of submersible pump Sets, submersible cable, column pipes, reonnecting main delivery mains as existing and testing for satisfactory running and continuous flow of water etc complete all as directed by Engineer in charge in bore wells at various locations under GE(A) Bhuj Note: 1 Repair to Motor & Pumping sets, cable and column pipes etc. shall be measured and paid seperately. 2. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out and lowering pump set etc shall be arranged by the contractor at his own cost.Lifting of defective submersible pumping set of any make and capacity from bore well after providing lifting tools , chain pulley etc. as required carefully, by disconnecting/dismentling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuse all complete all as specified and as directed. NOTE : (i) The cost of transportation of the defective submersible pumping sets( pump or motor ) from site to workshop & back is deemed to be included in the quoted rates. (ii) Repair of motor and pump measured separately (iii) Refixing of column pipe to be done after proper descaling using steel wire brush.
Dismantling and strip opening of submersible pump & motor of any description and in any position for servicing /overhauling, cleaning, oiling/greasing, fixing of serviceable parts in position, removing & replacement of defective / unserviceable parts with new parts and reassembling the pump and motor, ensuring proper alignment of pump and motor, fixing in position, connecting to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-Charge for the following capacities pumps & motors :- (a) 30 to 50 HP, three phase, 415 Volts, 50 Hz, AC supply Note: - (i) The replacement of defective / unserviceable parts shall be measured and paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing rate for new items are deemed to include under these item. (ii) Burnt out windings of motor shall be replaced, measured and paid separately under appropriate item of Sch ‘A’ for rewinding. (iii) (a) The rates for above items are deemed to include transportation of pumps/ motors to and from workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at authorised workshop. (b) Re-metalling to Pump shaft, polishing and grinding and making standard size to matching with Gun Metal Bush / Neck-ring shall be measured and paid for separately under appropriate item of Sch ‘A’ (iv) Lifting of pump and motor from bore well and lowering of pump and motor after repairs shall be measured and paid separately under appropriate item of Schedule `A'.-
M&L for rewinding of burnt submersible motor 30 to 50 HP, 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works including painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of motor external surface and water proof jointing for submersible cable 3 core, with replacement of oil seal, sand guard, bolt gusket, cable packing ring, water seal, bearing bush upper & lower etc complete all as specified and as directed.
Supply and fix in repair HDPE (High density polyethylene) pipe, PE-63 grade, ISI marked , as per IS 4984, PN 10, size 3 inch, Outer dia 90 mm, 10 kg/cm2, suitable for bore wells complete including providing suitable size MS clamps and SS nipples of flange/threaded type (made of SS-402 material) for connecting with submersible pump set and delivery mains, etc all as specified and directed. Note : Contractor Shall obtain and provide HDPE pipe in one length as required for borewell.
S&F polypropelene rope 32 mm dia, confirming to IS standard, heavy duty grade for securing the submersible pump set alongwith column pipes of borewells all as specified and directed Make : GARWARE or equivalent
S&F in repair adaptor set 90 mm dia for connecting the submersible pump set with the HDPE pipes complete all as specified and directed.
M & L for cleaning of complete UG sump of capacity 50000L by removing all sludge, mud, sand, green ulgae etc and any other foreign materials from the bottom, side walls and internal surfaces with high pressure pump to the satisfaction of Eng-in-charge complete all as specified and directed. Note :- No T & P will be provided by the Deptt. The contractor shall be fully responsible for the safety and security of the labour deployed for this work. The sludge / waste materials shall be thrown away from the pump house / sump premises where directed by the Eng-in-charge but exceeding 250 mtrs and not exceeding 500 Mtrs away with totaly unhygenic conditions without creating any nuisance in the environment.
Taking up/down Old unserviceable steel tubing and connections for pipe Bore of pipe 50 mm complete all as specifed and as directed.
Supply and laying of galvanised steel water tubing medium grade in trenches / wall /floor with all fittings,connections as required at site of size 40 mm bore complete all as specifed and as directed. :- Make : Tata/Jindal
S&F ball valve gun metal valve with iron handle screwed both ends for iron pipe and fixed of size bore of pipe 50 mm
NOTE APPLICABLE FOR ITEM NO. 57.00 TO 101.00:-
(1) The contractor shall keep all items readily available at site, which is required for urgent repair works of appliances.
(2) In case of absence of manpower without providing suitable replacement an amount of Rs 1000/- per day shall be recovered as liquidated damage per person per day from the bill.
(3) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.
(4) All tools &tackles, plants, machineries, equipment and material to carry out the work at site which is to be decided by GE (A) Bhuj shall have to be provided by the contractor at his/ her own cost.
(5) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(6) The electrician on duty round the clock will have to be available at the site service centre created by the contractor & should have mobile phone. In case of absence of electrician, Rs 500/- will be levied as penalty for each instance.
(7) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm.
(8) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration.
(9) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(10) The contractor shall ensure that his repair/ maintenance staff is qualified and licensed for their part of work. He shall be responsible for their conduct. The contractor shall be held responsible for any loss or damage to employees’ state insurance corporates property.
(11) All repair and maintenance related complaints shall be attended within two hoursfailing, which a recovery of Rs 500/- per event per hour shall be made from the subsequence payment of the contractor.
(12) It is responsibility of contractor to clean the area after repairwork of appliances. Rates are deemed to be include in his quoted rates of respective items.
(13) The contractor provide test certificate of material to be incorporated in the work.
(14) Any of contractor persons causes damage of equipment or property of Militart station, the contactor will be solely held responsible for the cost of consequences thereof.
(15) In the event of the contract work getting delayed due to reasons attributable to the contractor, the department shall be levying the penalty at the rate of 5% per week to the maximum of 10% of the contract value.
(16) Contractor shall carry out all test. The equipments shall conform to Indian standards.
(17) Work diary & hindrance register of maintained by the contractor. The both shall be deposited to department daily.
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
sudarshan builders (BID ID -3136314)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .