Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹37.9 LAccepted-AOC HAVELI FALIYA NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | ₹37.9 L | L-1 | Accepted-AOC Accepted |
| 2 | L-2₹42.4 L+₹4.5 L (11.9%)Rejected-AOC NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | ₹42.4 L+₹4.5 L (11.9%) | L-2 | Rejected-AOC Not accepted |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Admitted as firm not enlisted with reqd cat and also not uploaded the past exp of similar nature of work |
| 4 | Rejected-Technical OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | - | - | Rejected-Technical Not Admitted as firm not enlisted with reqd cat and also not uploaded the past exp of similar nature of work |
| 5 | Rejected-Technical OFFICE 4 B JAY TENAMENT MADHUWAN PARK II BEHIND NIRMAL NAGAR RAMESHWAR NAGAR JAMNAGAR 361006 | JAMNAGAR | GUJARAT | 361006 | - | - | Rejected-Technical Not Admitted as firm not enlisted with reqd cat and also not uploaded the past exp of similar nature of work |
Tender Value
Refer Docs
EMD Value
₹75,600
Closing Date
21 Feb 2023, 6:00 pmClosed
GE AF Naliya No 1
GE Air Force Station Naliya No 01
REPAIR AND MAINTENANCE OF RMU, VCBS, HT UG CABLE AND OTHER MISC REPAIR ON AC PLANT AT AF STN NALIYA
2023_MES_578599_1
8871/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naliya
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF Naliya No 1
₹75,600
Yes
3 Jul 2023
2 Feb 2023
23 Feb 2023
2 Feb 2023
21 Feb 2023
16 Feb 2023
2 Feb 2023 - 9 Feb 2023
Amount
M&L for Maintanance, Calibration of VCB / RMU relay by injecting High voltage through CTS checking the over load system of VCB up to 90 % rated load and artificial fault creation and setting of relay by 10 to 15 % of rated load removing u/s overload and earth fault relay including connection with power pack, opening out the trolley, checking the operation of VCB mechanically and electrically through shunt trip coil including energizing of springs automatically, checking of TNC switch including testing and commissioning complete all as directed by Engr-in-Charge. Note:- Maintaenance, Calibration to be carried out by authorised person and test certificate shall be furnished during payment.
Replacement of complete power pack unit of 220 V/110 V AC input and 110 V/24V DC output fixed inside the HT VCB/RMU unit complete for back up of the tripping system of Circuit Breaker etc. complete all as specified and as directed.
Supply install and testing in replacement of digital four pole non directional Microprocessor based IDMTL 3 over current +1 Earth fault with instantaneous element relay with high set & Aux. supply 20-110 volt DC as per existing make and model complete all as specified and directed by Engr-in-Charge
M&L for replacement of automatic spring charge motor of the Vacuum circuit breaker of existing make and model complete all as specified and directed.
S & F in replacement of 11 KV current transformer (CTs) for HT panels indoor type resin cast epoxy type of 13.1 KA/sec having ratio 60/5+5 Amps suitable for metering and protection of panels including control cables as per site requirement and fixing on bus bar section having class of accuracy 5P10, burden 15 VA complete all as specified and directed.
S & F in replacement PT unit three phase three limb, epoxy type up to 11 KV draw out type single ratio having primary 11 KV & secondary voltage 110 volts 200 VA class I, including necessary bus bar connection & wiring for metering after disconnecting of HT supply from HT VCB of capacity 630 Amps complete all as directed.
S&F in replacement of vaccum interrupter as per existing make and model and suitable for 11 KV HT VCB 11 KV 630/800A capacity complete all as specified and directed.
S&F in replacement fixed contact block as per existing make and model and suitable for V.C.B 11 KV 630/800 Amps capacity complete all as specified and directed.
S&F in replacement moving contact block as per existing make and model and suitable for V.C.B 11 KV 630 /800 Amps capacity complete all as specified and directed.
S&F in replacement motor & gear assembly 220Volt AC motorised mechanism as per existing make and model and suitable for V.C.B 11 KV 630/800 Amps capacity including testing & putting on load complete all as specified and directed.
S&F in replacement closing coil assembly 24/110V DC as per existing make and model and suitable for HT VCB 11 KV 630/ 800A capacity complete all as specified and directed.
S & F in replacement tripping coil assembly 24/110V DC as per existing make and model and suitable for HT VCB 11 KV 630/800A capacity complete all as specified and directed.
S & F in replacement auxiliary switch (6 No+6NC) as per existing make and model and suitable for HT VCB 11 KV 630/800 Amps capacity complete all as specified and directed.
M&L for tracing out HT cable fault through HT fault locator machine by HT expert and testing of HT cable through megger and repair the same. Note:- The cost of the earth work, equipment and person required for locating fault is inclusive in unit rate (ii) Joint of cable will be measured separately under relevant item.
Labour for shifting of RMU/VCBs panel complete from one place to another place by disconnecting its all electrical connections transporting though their own veh and loading unloading etc. Note- The cost of the transporting veh and crane is deemed to be included in unit rate.
Supply, jointing and testing of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 50 sqmm to 95 sqmm complete all as Specified and directed.
Supply jointing and testing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of 50 to 95 Sqmm complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 50 to 95 sqmm. complete all as specified and directed.
Supply ,jointing and testing of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 to 185 sqmm complete all as directed.
Supply, jointing and testing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of 120 to 185 Sqmm complete all as specified and directed.
Supply, jointing and testing cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 to 185 sqmm. complete all as specified and directed.
M& L for cutting under the road /pavement /hard standing or in any other situation with the help of manual labour for crossing of U/G cable through it and making both the end good complete all as specified and directed .
Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings ISI marked and laid in trenches under roads, through drains, fixed to poles/walls with required size flat iron clamp bolts, nuts and washers, for cable protection of 100 mm dia, including taking out old/existing pipes, complete all as specified and directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Taking out HT UG cables of 95/120 Sqmm by excavation and earth work in any type of soil, removing bricks or PCC cover of any size, stacking serviceable cable for reuse complete all as specified and directed NOTE:- (i) Excavation, Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separately.
Supply & fix HT 11 KV 3 core 95 Sqmm cable in trenches/fixed to poles/wall, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable( HT ), heavy duty with aluminum conductor, 11000 volts (earthed) grade 95 Sqmm x 3 core all as specified and directed by EIC.(Note : (i) Excavation, earthwork, cable joints, sand cushioning & cable cover will be measured and paid separately if required
Re-laying the serviceable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor, 11000 volts Earthed, grade cross sectional area 95/120 sqmm 3 core in trenches/fixed to poles/wall, complete all as specified and directed by EIC.(Note : (i) Excavation, earthwork, cable joints, sand cushioning & cable cover will be measured and paid separately if required)
M&L for sand cushioning for UG cables using dry sand; gently punning down all as directed and specified. (Note : For measurement purpose punned thickness shall be considered)
Supply and laying unreinforced precast concrete cable covers class HV type I, flat size 300x180x40 mm laid transverse to cable.
Labour for relaying of unreinforced precast concrete cable covers class HV type I, flat size 300x180x40 mm laid transverse to cable.
Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points.
Supply fabricate, testing and commissioning of factory made HT outdoor distribution panel board single door of size 1200mm x 1200mm x 800mm including locking arrangement cubical type dust and virmin proof, weather proof, aesthetical designed, IP54 degree of ingress protection, fabricated with 3mm thick CRCA sheet with front and rear opening including 3 strips of copper bus bar of 600 Amps current carrying capacity insulated with colour sleeves, porcelain/epoxy insulators 11000V, rail channel, cable entry, danger notice plate of 11000 Volt, angle iron frame of size 50x50x6mm and 60cm grouted in ground and 60cm above GL including necessary excavation, foundation, PCC etc. complete duly powder coated of approved colour all as specified and directed by Engr- In- Charge.
Trimming of tree branches touching to over head lines, up to 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearance of HT/LT pole and sub station premises all as directed Note: (i) Trimming of all branches of trees falling under one span between two pole shall be considered as one span only. (ii) Contractor have to arrange all T&P, safety equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishappening occurred due to negligence of safety aspects.
Dismantling / taking down in repairs the street light / security lights of any capacity & description from existing LT pole/walls at any height and refixing the fittings in existing / another location after repair work all as directed by Engr-in-charge. Note:- (i) Replacement of defective parts / accessories shall be measured and paid separately under relevant items. (ii) Transport and T & P i.e. Ladder, safety items, or any other equipment for repair of street light shall be provided by Contractor and cost for the same deemed to be incl in respective items
S&F in repair LED driver 45/48W 1500mA suitable for LED light fitting
S&F in repair LED driver 72W/80W 2600mA suitable for LED light fitting
S&F in repair LED driver 100W,2600mA suitable for LED light fitting
S&F in repair LED driver 150/240W3000mA suitable for 240 watt LED light fitting
S&F in repair MH ballast 70W suitable for 70 watt MH light fitting complete all as directed
S&F in repair MH ballast 150W suitable for 150/250 watt MH light fitting
S&F metal halide ballast 250W suitable for 250 watt MH light fitting complete all as directed
S&F in repair MH lamp 70W suitable for 70 watt MH light fitting complete all as directed
S&F in repair MH lamp 150W suitable for 150/250W MH light fitting
S&F in repair MH lamp 250W suitable for 400W MH light fitting complete all as directed
S&F in repair Igniter for MH lamp suitable for 70/150/250/400W MH light fitting
Taking down existing worn Blower moter of window type Air Conditioner of 1.5/ 2.0 Ton capacity and S&F in replacement new spares of existing make and model complete all as specified and as directed.
Description all as per Srl Item No 1.00 here-in-before but Blower capacitor 4/2.5 MFD.
Description all as per Srl Item No 1.00 here-in-before but Fan blade.
Description all as per Srl Item No 1.00 here-in-before but Air filter PVC.
Description all as per Srl Item No 1.00 here-in-before but Thermostat switch with knob.
Description all as per Srl Item No 1.00 here-in-before but Front grill of PVC.
Taking down Blower motor indoor type of split type Air Conditioners of 1.5/ 2.0 Ton capacity and S&F in replacement new spares of existing make and model complete all as specified and as directed:-
Description all as per Srl Item No 7.00 here-in-before but Blower motor outdoor type.
Description all as per Srl Item No 7.00 here-in-before but Fan blade.
Description all as per Srl Item No 7.00 here-in-before but Running/running capacitor of 50 & 60 MFD.
Description all as per Srl Item No 7.00 here-in-before but Air filter for Indoor unit.
Description all as per Srl Item No 7.00 here-in-before but Display for Indoor unit.
Description all as per Srl Item No 7.00 here-in-before but Remote control (Hand set only) with battery.
Description all as per Srl Item No 7.00 here-in-before but LDPE drain water pipe line 15 mm dia all as directed .
Description all as per Srl Item No 7.00 here-in-before but PCB Timer electronic switch with sensor suitable for existing make & model of split 1.5/ 2.0 Ton AC complete with hand set. Make-Voltas/Carrier/LG/LLOYD/Blue Star/VIDEOCON/Hitachi/Panasonic
M&L for opening the indoor unit front panel of wall mounted split type 1.5/ 2.0 Ton AC for cleaning the existing LDPE pipe for any block by blowing the pipe with air and cleaning the bottom water line of indoor unit for arresting leakage of water complete all as specified and as directed.
S&F in replacement rotary / invt type compressor of split type AC 1.5 Ton capacity in position, charging of refrigerant gas of required quantity, brazing of discharge and suction line and leak testing complete all as specified and as directed
All as per Item No. 17.00 above but for split type AC of 2.0 Ton capacity.
M&L for top up/ Gas charging with refrigerant gas (R-22) for Air Conditioner window/ split / packaged/ chiller type of capacity 1.5/ 2.0/ 5.5 / 11.0/16.5/17/36 Ton after vacuuming and leak testing including brazing suction/ discharge line and testing complete all as specified and as directed.
S&F in replacement of copper tubing (of dia 1/4" to 1/2" ) suction and liquid line from indoor to out door unit by compressing Ref Gas suitable for split AC of capacity 1.5 TR/ 2.0 TR including insulation on copper tubing complete all as specified and as directed. Each RM included Complete set of suction and discharge line)
Supply and fix in repairs voltage stabilizer of capacity 4 KVA, 230 Volts, AC, 50 Hz with range 160 Volts to 250 Volts with variation 2.5%+-complete all as specified and as directed.
Taking down existing split type AC of 1.5/ 2.0 Ton capacity, from one location and re- fixing the same in another location as directed, including replacement of 3 core copper cable require for connecting IDU & ODU, additional copper tube if required, cleaning the IDU and ODU for smooth functioning etc. complete all as specified and as directed.
Taking out the window type AC of 1.5/ 2.0 Ton capacity, from one location and shifting to new location for re- fixing the same complete all as specified and as directed.
S&F in replacement industrial plug and socket with single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 16 Amp/ 20 Amps capacity complete all as specified and as directed.
S & F in replacement of PCB set (indoor-outdoor) electronic switch suitable for 1.5 / 2 TR split AC Inverter Type of Make Voltas/carrier/LLOYD/LG/Hitachi/Blue Star complete.
M&L for top up/ gas charging with refrigerant R-134 A of required quantity for water cooler/ water dispenser/ refrigerator/ deep freezer of any make including leak testing, necessary brazing of suction and discharge line and testing complete all as specified and as directed.
M&L for servicing/ cleaning of complete 1.5 TR capacity indoor/ outdoor window type and split type air conditioner units of following size and capacity by means of adding, cleaning solution (HCL) or equivalent solution with water. The cleaning of the condenser and chiller units is done with use of nylon brushers till the scaling is removed complete all as specified and as directed.
Description all as per Srl Item No.27.00 here-in-before but 2.0 TR Capacity.
Description all as per Srl Item No.29.00 here-in-before but 80/120 Liters.
M&L for top up/ Gas charging with refrigerant gas (R-410/R-32) for Air Conditioner window/ split type of capacity 1.5/ 2.0/ Ton after vacuuming and leak testing including brazing suction/ discharge line and testing complete all as specified and as directed.
S & F in replacement of heating coil of 2KW capacity suitable for 4 KW capacity humidifier complete all as specified and as directed.
S & F in replacement of heating coil of 3 KW capacity suitable for 09 KW capacity humidifier as per existing make and model all as directed by EIC.
Supply & fix in repair new compressor sealed units as per existing make and model, including brazing/ welding of suction and discharge line, Including first filling gas, cleaning or descaling of liquid line air dryer and leak testing complete, 5.5 Ton capacity suitable for 5.5/ (5.5X2)11/ (5.5x3)16.5 TR package AC complete all as specified and as directed by EIC. Make:- Tecumseh/ Kirloskar/ Blue star/ Copeland/ Voltas as approved by GE.
Supply & Fix in repair condenser motor of outdoor unit of any make and model as existing in position for unit dismantled including other connected accessories for 5.5 Ton/(5.5x2) 11 Ton, (5.5x3)16.5 Ton capacity package AC complete all as specified and as directed. Make:- AUE/ GE/ Crompton Greaves/ Blue star as approved by GE.
Supply & Fix in repair condenser motor of outdoor unit of any make and model as existing in position for unit dismantled including other connected accessories of (8.5x2) 17 Ton capacity package AC complete all as specified and as directed. Make:- AUE/ GE/ Crompton Greaves/ Blue star as approved by GE.
Supply & Fix in repair condenser motor of outdoor unit of any make and model as existing in position for unit dismantled including other connected accessories of (12x3) 36 Ton capacity package Chiller AC complete all as specified and as directed. Make:- AUE/ GE/ Crompton Greaves/ Blue star as approved by GE.
All as per Item No. 42.00 above but blower motor of indoor unit suitable for 5.5 Ton capacity package AC. Make:- AUE/ GE/ Crompton Greaves/ Blue star as approved by GE.
Dismantling and taking out Compressor hermetically sealed suitable for 40/ 80 liter capacity water cooler from the existing water cooler/ refrigerator/ deep freezer after cutting carefully the suction and discharge line and S&F in replacement new compressor including first filling of gas and refining serviceable accessories with brazing the suction and discharge line and leak testing complete all as specified and as directed:- Make:- Tecumseh/ kirloskar/ Bluestar/ Voltas as approved by GE.
Description all as per Srl Item No.50.00 here-in-before but Compressor hermetically sealed suitable for refrigerator of 165 to 310 Liters capacity.
Description all as per Srl Item No.50.00 here-in-before but Compressor hermetically sealed suitable for 200 to 320 Liters capacity deep freezer.
S&F in replacement water cooler 40/ 80 Liters capacity thermostatic switch completed. Make:- Donfoss/ Indofoss as approved by GE.
Description all as per Srl Item No.53.00 here-in-before but Deep freezer of any capacity.
Refrigerator 165 to 290 ltr capacity.
S&F in repairs blower motor suitable for water cooler 1/32 HP or 1/35 HP, single phase, 230 Volts, 1300 RPM complete all as specified and as directed Make:- AUE/ GE Motors as approved by GE.
S&F in replacement fan motor with blade suitable for Deep Freezer of any capacity complete all as specified and as directed. Make:- AUE/ GE as approved by GE.
S&F in replacement of burn out PCB unit box unit complete with all connecting Items, of existing make, for 5.5 TR capacity package AC complete all as specified and as directed.
S&F in replacement of burn out PCB unit box unit complete with all connecting Items, of existing make, for (5.5X2) 11 TR capacity package AC complete all as specified and as directed.
S&F in replacement of burn out PCB unit box with display unit complete with all connecting Items, of existing make, for (5.5x3) 16.5 TR capacity package AC complete all as specified and as directed.
S&F in replacement of burn out PCB unit box with display unit complete with all connecting Items, of existing make, for (8.5x2) 17 TR capacity package AC complete all as specified and as directed.
S&F in replacement of burn out PCB unit box with display and remote unit complete with all connecting Items, of existing make, for (12x3) 36 TR capacity package chiller AC complete all as specified and as directed. Make-Blue Star
S&F in replacement 'V' belt of existing size suitable for indoor unit of 5.5/ (2x5.5) 11/(5.5x3) 16.5 /(8.5x2)17 / (12x3)36 Ton capacity package/chiller type AC unit of existing make complete all as specified and as directed.
S&F in replacement contactor, 3 Phase suitable for existing 5.5/(5.5X2)11 TR/ (5.5x3) 16.5TR/ (8.5x2) 17 TR/ (12x3) 36 TR capacity package type AC unit of existing make complete all as specified and as directed. Make:- L&T/ Siemens/ Minilec as approved by GE.
Cleaning of outdoor condenser coil and indoor evaporating coil using suitable cleaning chemical, washing of filters after cleaning of paint the compact unit of various size of package type AC units of 5.5 TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed.
Cleaning of out door condenser coil and indoor evaporating coil through suitable cleaning chemical, washing of filters after cleaning of paint the compact unit of various size of package type AC units of (5.5X2) 11 TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed. .
Cleaning of out door condenser coil and indoor evaporating coil through suitable cleaning chemical, washing of filters after cleaning of paint the compact unit of various size of package type AC units of (5.5x3) 16.5TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed. .
Cleaning of out door condenser coil and indoor evaporating coil through suitable cleaning chemical, washing of filters after cleaning of paint the compact unit of various size of package type AC units of (8.5x2) 17 TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed. .
Cleaning of out door condenser coil and indoor evaporating coil through suitable cleaning chemical, washing of filters after cleaning of paint the compact unit of various size of package type Chiller AC units of (12x3) 36 TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed. .
S&F in replacement of indoor unit of Split AC suitable for 1.5TR / 2.0 TR Split AC as directed by EIC.Make:-Blue Star/Voltas/LG/SAMSUNG etc
S&F in replacement Starting Capacitor of 80 to 100 MFD complete all as specified and as directed. Make:- Tibcon/ Kerlton/ Usha as approved by GE.
S&F in replacement motor protection device (MPD) suitable for (8.5x2) 17 TR capacity Package type AC complete all as specified and as directed.
S&F in replacement 100 Amps MCCB, 3 pole , 25 KA, with fixd thermal setting complete all as specified and as directed.
S&F in replacement MCB TPN, 63 Amps, 10 KA, complete all as specified and as directed
M & Labor for complete servicing / fault finding any type by OEM rep / service engineer incl opening of evaporating/condensing unit of (12x3) 36 TR package type Chiller AC units, (5.5x3)16.5 TR Packaged AC, (5.5x2) 11 TR Packaged AC, 5.5 TR Packaged type AC and (8.5x2) 17 TR Packaged type AC for servicing of condenser motor or for finding out any leakage of refrigerant from suction or discharge line and stop the leakage by gas welding / brazing and again Nitrogen gas charging for 48 Hrs for checking any leakage in line and cleaning of air filter, indoor water storage tray and drain, including any minor parts etc, rectify if any water leakage, refixing, re-assembling the evaporating/condensing unit and making good and re-fixing after repair work is completed, complete all as specified and as directed. (Note: Ref gas if required paid in separate item of BOQ)
S&F in repairs single/ three phasing preventer suitable for 5.5 TR/ (5.5X2)11 TR/ (5.5x3) 16.5TR/ (8.5x2) 17 TR/ (12x3) 36 TR package type AC units of existing make complete all as specified and as directed.
S&F in replacement condenser coil made up of copper for split type AC of capacity 1.5 TR/ 2.0 TR complete all as specified and as directed.
Dismantling of 5 HP monoblock pump set for replacement of bearing/ serving etc complete and refixing the same after repairs complete all as specified and as directed.
M&L for rewinding of monoblock pump set of 5HP with copper winding coils of same guage as burnt complete and testing the same with rated current complete all as specified and as directed.
S&F in repairs gas charging valve of suction or discharge line suitable for 5.5 Ton/ 11 Ton/ 16.5/36 TR capacity Packaged / Chiller AC units as per existing make and model complete all as specified and as directed.
S&F in repairs expansion valve suitable for 5.5Ton/ (5.5X2) 11 Ton/ (5.5x3)16.5 TR capacity AC units (Carrier/voltas/Bluestar) as per existing make and model including cutting, brazing/ welding, leak testing etc complete all as specified and as directed.
S&F in repairs expansion valve suitable for (8.5X2) 17 Ton capacity AC units (Carrier/voltas/Bluestar) as per existing make and model including cutting, brazing/ welding, leak testing etc complete all as specified and as directed.
S&F in repairs expansion valve suitable for (12X3) 36 Ton capacity Chiller AC units Bluestar make and model including cutting, brazing/ welding, leak testing etc complete all as specified and as directed.
M&L for submain wiring with two runs of single core, 1100 Volts grade multistranded copper conductor cable of size 4.0 sqmm, PVC insulated, unsheathed, fire retardant low smoke (FRLS) drawn through and including PVC casing and capping of suitable size with all necessary fittings and one run of single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke (FRLS) as earth wire, fixed on wall/ ceiling complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable and one run of 2.5 sqmm cable as earth wire and one run of PVC casing and capping with casing/ capping accessories shell be measured as one unit.
M&L for carefully opening the AC units, taking down defective parts/ accessories (Duct, bearing, Shaft along with blower motor etc.) for repairs after disconnecting electric connections and re-assembling the AC after repairs and re-fixing only serviceable accessories and re-fixing the ACs to its original position including bearings quantity 02 Nos and V belt. and testing complete for 5.5/(2 x 5.5) 11/ (3x5.5) 16.50 Ton capacity package AC complete all as specified and as directed.
Supply and fix in replacement of three phase DOL starter suitable upto 5/7.5 HP rating complete all as specified and as directed.
Supply & Fix in replacement of new compressor sealed unit sutiable for existing make and model, including brazing/ welding of suction and discharge line, including first filling gas, replacement of liquid line air dryer and leak testing complete, 8.5 Ton capacity suitable for (8.5X2) 17 TR package AC unit complete all as specified and as directed. Make:- Tecumseh/ Kirloskar/ Blue star/ Copeland/ Godrej/Denfos as approved by GE.
Supply & fix in replacement of new compressor sealed unit suitable for existing make and model, including brazing/ welding of suction and discharge line, including first filling gas,replacement of liquid line air dryer and leak testing complete, 12.0 Ton capacity suitable for (12X3) 36 TR package AC unit complete all as specified and as directed. Make:- Tecumseh/ Kirloskar/ Blue star/ Copeland/ Godrej /Denfos as approved by GE.
Anil Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .