| 1 | L1₹18.3 LAccepted-AOC DHALESWAR AGARTALA WEST TRIPURA PIN 799007 | AGARTALA | WEST TRIPURA | TRIPURA | 799007 | ₹18.3 L | L1 | Accepted-AOC STOOD L1 |
| 2 | L2₹18.5 LRejected-Finance NORTH BADHARGHAT TRIPURA W PIN 799003 | WEST TRIPURA | TRIPURA | 799003 | ₹18.5 L | L2 | Rejected-Finance HIGHER THAN L1 |
| 3 | L3₹19.0 LRejected-Finance AGARTALA TRIPURA W PIN 799008 | WEST TRIPURA | TRIPURA | 799008 | ₹19.0 L | L3 | Rejected-Finance HIGHER THAN L1 |
Tender Value
₹21.1 L
EMD Value
₹42,164
Closing Date
27 Jan 2026, 2:00 pmClosed
The Executive Engineer Agri West Agartala
The Executive Engineer West-I Department of Agriculture and F W Agartala Tripura
Preparation of estimate Against Master Plan on design of Landscaping and Beautification with overall Infrastructure Development of Rabindra Kanan Amusement Park SH Cafeteria.
2026_AGRI_69338_1
65/AGRI/EE(WEST-I)/2025-26
Open Tender
Civil Works
90 days
Rabindrakanan Agartala
AS PER DNIT
7 documents required · 7 mandatory
₹1,000
₹42,164
20 Mar 2026
17 Jan 2026
27 Jan 2026
18 Jan 2026
27 Jan 2026
19 Jan 2026
Earth work in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil
Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level: a)1:4:8 ( 1 Cement: 4 fine sand : 8 graded well burnt brick aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto plinth level: 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- a) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregat 20 mm nominal size)
Centering shuttering including struttings, propping etc. and removal of form work with Timber Plank: a) Foundations, footings, bases for columns.
Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply
Suspended floors, roofs, landings, balconies and access platform with shuttering ply:
Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply:
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (Thermo-Mechanically Treated bars of grade Fe-500D or more)
Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :Local Teak Wood
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality)
Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete.
Providing & fixing in position treated (as per IS 401) rubber wood wall cladding at all height with finger jointed edge glued solid rubber wood board planks of sizes 12 mm thick, 1000mm length (minimum) and 100 mm wide (minimum), in approved colour, texture and finish, with necesasary profiled edges fixed with 40mm SS screws 5 nos in each tile to frame work made of treated rubber wood of size 50mmx25mm placed at 500mm (maximum) apart and Performance Appraisal Certificate (PAC) issued by TFDPC Ltd) All complete as per direction of the Engineer in-charge.
Providing and fixing Marble stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge: 18 mm thick Marble stone
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge.
12 mm cement plaster of mix In cement mortar 1:4 ( 1 cement : 4 fine sand ).
15 mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand)
6 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr
Two or more coats of glue with spar varnish over an under coat of flatting varnish.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :-the periphery of the area cleared.For fixed portion of approved quality:-Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodiccoating of grade AC 15).
Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm )
With float glass panes of 8 mm thickness ( weight not less than 20 kg / sqm )
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embrossed on the body / plate with double spring mechanism and door weight upto 125 kg. for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece MS sheet outer box with slide plate etc. complete as per direction of the Engineer-in-charge:-With stainless steel cover plate minimum 1.25 mm thickness
Filling the gap in between aluminium frame and adjacent RCC/brick work by providing weather silicon sealant over backer rod of approved quality etc. complete as per architectural drawing and direction of the Engineer-in charge:- (i) Upto 5 mm depth and 5 mm width.
Powder coated aluminium minimum thickness 50 micron
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 18.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 18.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 18.28.1 Semi rigid piperequired :18.9.1 White glazed fire clay kitchen sink of size 600x450x250 mm.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Providing and fixing on wall face unplasticised Rigid PVC soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: (75 mm dia)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. a) 15 mm nominal outer dia .Pipes.
b) 20 mm dia waste pipe
c) 32 mm dia waste pipe
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_70554.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.79 MB
DNIT65.pdf
Tender Documents • 3.01 MB
BOQ_70554.xls
BOQ • 0.33 MB