| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹20.8 L+₹84,383.39 (4.24%)Rejected-Finance NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-Finance Quoted rates higher than L1 | |
| 3 | L3₹21.8 L+₹1.8 L (9.27%)Rejected-Finance | L3 | Rejected-Finance Quoted rates higher than L1 | |
| 4 | L4₹22.5 L+₹2.6 L (12.9%)Rejected-Finance | L4 | Rejected-Finance Quoted rates higher than L1 | |
| 5 | L5₹22.8 L+₹2.8 L (14.3%)Rejected-Finance | L5 | Rejected-Finance Quoted rates higher than L1 |
Tender Value
Refer Docs
EMD Value
₹43,600
Closing Date
14 Feb 2024, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Provn of anti suicidal fan rods and 15 amp power sockets in certain married Accn and upgradation of 04 nos LT panels at AF Stn Suryalanka
2024_MES_637972_1
CWE(AF)/TVM/82483E8 Antisuicidal fan Suryalanka
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Suryalanka
Class E category b(i)
6 documents required · 6 mandatory
₹500
AGE I AF Suryalanka
₹43,600
Yes
27 Mar 2024
17 Jan 2024
16 Feb 2024
17 Jan 2024
14 Feb 2024
31 Jan 2024
18 Jan 2024 - 24 Jan 2024
Amount
SCHEDULE 'A'
M&L for Taking down ceiling fan any make and sweep, cleaning externally and internally by removing Electrical connections, Fan rod, Clamp, Rubber bush etc..for repalcement of fan rod with Anti suicidal rod and Refixing of fan duly clean in all respect with new fan rod complete all as specified and directed.
M&L for Rubber bush for shackle with clamp, bolt, nut, washers and lock pin suitable for Ceiling fan anti suicidal fan rod of 1200mm/ 1400mm sweep complete all as secified and dirtected.
S & F of Smart Fan Rod / Anti Suicide Fan Rod bearing capacity not exceed to 25 kgs it should suitable for any company of fan and length not less than 300mm and not more than 1500mm (as same as existing rod lenght) complete all as Specified and directed . Note :- (i) The contractor should submit Guarantee certificate for 5 years and test certificate from the manufacturer with construction details . (ii) The fan rod shall be epoxycoated / painted with anticorrosive paint. (iii) The fan rod should be ISI marked. (iv) Quoted rates are deemed to be included for all the above provisions and any other requirements as per manufactures instructions.
S&F in replacement Three core 0.5 sqmm flexible multi strandard copper wire for connecting ceiling fan/ exhaust fan/ wall fan to ceiling rose all as specified and as directed.
S&F submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 4 Sqmm copper multistranded conductor including and on surface rigid PVC conduit of dia 20mm fixed on wall/ceiling including 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete all as specified and as directed.
S&F modular switch socket combination 16A, 6 pin, 3 module complete all as specified and as directed.
S&F 3 Module Cover Plate with frame and Metal Flush Box fixed on walls/ tiles etc complete all as specified and as directed.
S&F in replacement of MCB, SP 10 Amps to 20 Amps, C Curve, 10 kA, Complete all as specified and as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded of size 10 Sqmm including taking down old unsv service cable complete all as specified
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded of size 6 Sqmm including taking down old unsv service cable complete all as specified
Supply and fixing XLPE insulated, armoured heavy duty electric UG cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core including necessary arrangement for fixing on wall, roof etc by using clamps, screws etc or laying of cable complete all as specified and directed
All as per item no 12 above but cross-sectional area 25 sq. mm 3.5 core
All as per item no 12 above but cross-sectional area 35 sq. mm 3.5 core
All as per item no 3 above but cross-sectional area 50 sq. mm 3.5 core Note 12 to 15 : Excavation/returning and re-filling will be measured and paid separately under respective items
Excavation in trenches,in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 m in wide for laying of cable,RCC Poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and as directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified.
M & L for sand cushioning to underground cable including punning down of sand in layer complete all as specified and directed. Note :- Punned down thickness shall be measured for payment
M&L for laying common burnt bricks, sub class 'B', of size 230 x 115 x 75 mm in trenches for cable protection complete all as specified and as directed.
M&L Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting complete all as specified and directed
M&L for Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI strip 32X6 by means of bolts, check nut and washers of GI or steel, GI pipe medium grade of 40 mm bore as protection pipe, GI strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia medium grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor type, double door on both sides made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 600 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided as per latest IE, the space between ground to panel should be 20 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, suitable size of lugs to connect cable to the panel I/C and O/G, internal wiring with FRLS copper wires and comprising and including the following (MES Sub Stn):- Incoming: a) MCCB 4 Pole, 400 Amps, 36 kA, Adjustable thermal and adjustable magnetic setting. - 01 No. Outgoing: a) MCCB 3 Pole, 200 Amps, 36 kA, Adjustable thermal and adjustable magnetic setting. - 01 No. (for MRS Panel) b) MCCB 3 Pole, 125 Amps, 36 kA, Adjustable thermal and adjustable magnetic setting. - 01 No. (MES Colony) c) MCCB 3 Pole, 63 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting. - 01 No.(Street light panel AGE Office front)
d) MCCB 3 Pole, 100 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting. - 03 No.(AGE Office - 01, Spare - 02) e) MCB TPN 40 Amp, 10 kA, . - 01 No.(Street light) f) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs g) LED indicating lamps with colour Red, Yellow, Blue - 01 Set h) Street light timer with contacts 3 Ph - 01 Nos (j) Capacitor bank 10 KVAR - 02, 5 KVAR - 01, 3 KVAR 01 with APFC relay and necessary control like contacts etc
Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor type, double door on both sides made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 200 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided as per latest IE, the space between ground to panel should be 20 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, suitable size of lugs to connect cable to the panel I/C and O/G, internal wiring with FRLS copper wires and comprising and including the following (Near MRS BSO):- Incoming: a) MCCB 4 Pole, 125 Amps, 36 kA, Adjustable thermal and adjustable magnetic setting. - 01 No. Outgoing: a) MCCB 3 Pole, 63 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting. - 01 No.(Guard room Main gate) b) MCB TPN 40 Amp, 10 kA, . - 10 No.(BSO store yards - 08, Spare - 02) c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs d) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor type, double door on both sides made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 300 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided as per latest IE, the space between ground to panel should be 20 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, suitable size of lugs to connect cable to the panel I/C and O/G, internal wiring with FRLS copper wires and comprising and including the following (Near Area Drainage PH):- Incoming: a) Onload change Over 4 Pole, 200 Amps, 36 kA, Adjustable thermal and adjustable magnetic setting. - 01 No. b) MCCB 4 Pole, 125 Amps, 36 kA, Adjustable thermal and adjustable magnetic setting. - 01 No. Outgoing: a) MCCB 3 Pole, 63 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting. - 04 No.(Street lights - 2, PH -1 & Spare 01) b) MCB TPN 63 Amp, 10 kA, . - 02 No.(Offrs beach-01, Spare - 01) c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs d) LED indicating lamps with colour Red, Yellow, Blue - 01 Set (e) Capacitor bank 5KVAR - 01 with APFC relay and necessary control like contacts etc f) Street light timer with contacts 3 Ph - 01 Nos
Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor type, double door on both sides made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 200 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided as per latest IE, the space between ground to panel should be 20 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, suitable size of lugs to connect cable to the panel I/C and O/G, internal wiring with FRLS copper wires and comprising and including the following (Near Dolphin Beach):- Incoming: a) MCCB 4 Pole, 125 Amps, 36 kA, Adjustable thermal and adjustable magnetic setting. - 01 No. Outgoing: a) MCCB 3 Pole, 63 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting. - 01 No.(Guard room Main gate) b) MCB TPN 40 Amp, 10 kA, . - 4 No.(Beach-01, Tower - 02 & Spare-01) c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs d) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
Total of Schedule 'A'
ARUNOTHAYA TRADERS
PAVANI INFRAS
B5BUILDING SOLUTIONS
BEEGEE DESIGN SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .