Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.1 L+₹25,471.62 (2.88%)Rejected-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L2 | Rejected-Finance Since not L1 | |
| 3 | L3₹9.3 L+₹42,736.94 (4.83%)Rejected-Finance | L3 | Rejected-Finance Since not L1 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
9 Nov 2020, 6:00 pmClosed
D Barman, AE(Civil)
AGE(I) FY Eddumailaram
REPAIR/MAINTENANCE OF OLD UNSERVICEABLE LT PANELS AT CERTAIN PLACES OF CQA (ICV) AND MES UNDER AGE (I) FY EDDUMAILARAM
2020_MES_385564_1
8252
Open Tender
Electrical Maintenance Service
Item Rate
180 days
Eddumailaram
Class E Category b(i)
5 documents required · 5 mandatory
₹500
Yes
AGE I FY
₹19,000
Yes
13 Jan 2021
12 Oct 2020
14 Nov 2020
12 Oct 2020
9 Nov 2020
26 Oct 2020
Amount
Surface dressing not exceeding 15cm deep in soft/ loose soil including taking out grass, bushes etc complete all as specified & directed.
M&L for hard core of gauge exc.63mm but not exc 100 mm, deposited ,spread and levelled in layers nexc.15cm thick, watered and rolled /rammed to a true surface complete all as directed.
Supply and fix MCCB 400 Amps 4 pole 50 KA 415 Volts 50 Hz with thermal adjustable magnetic settings including taking out old existing unserviceable MCCB from panels etc complete all as directed. Make :Indo Asian/Havells / Legrand/ Schneider/Seimens
All as per srl item No. 3 here in before but 250 Amps 36KA
All as per srl item No. 3 here in before but 200 Amps 36 KA
All as per srl item No. 3 here in before but 160 Amps 36 KA
All as per srl item No. 3 here in before but 100 Amps 25 KA
All as per srl item No. 3 here in before but 63 Amps 16 KA
All as per srl item No. 3 here in before but 40 Amps 16 KA
Supply and replaced Synthetic insulating mat of size 2mx1mx25mm.confirming to IS: 15652-2006 ISI marked suitable up to 11 KV Colour blue standard roll complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Power contactor 40 A, 4 pole of timer panel Make : INDO ASIAN/HPL/ L&T/ Havells
M&L in replacement of LT U/G cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area of following sizes. (a) 70 Sqmm 3.5 Core
(b ) 95 sqmm 3.5 core
(c) 120 sqmm 3.5 core
(d) 300 sqmm 3.5 core
Supply and fixing in replacement of digital type time switch 3P module, DIN 24 hours programmable every 1 minutes with 28 memory location of current capacity 16 Amps with one change over including connecting to existing power contactor complete. Make : Indoasian Cat Part No. TDA43110 or equivalent in HPL/L&T/havells
M&L for PCC (1:3:6) type C1 using 20 mm graded stone aggregate for making coping of LT poles or stage for garden lights or grouting of panels as specified and directed by Engr-in-Charge .
Cutting and trimming of tree branches to clear OH lines in the area of LT OH lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of tree) and removal of the trimmed branches of trees and depositing the same in ODF FY waste bins inside the campus complete all as specified and directed by Engr-in-charge.
M&L for Preparing existing old surface of steel tubular poles of any type 12 Mtr height for painting one coat of aluminium paint on the surface of steel tubular pole and channels/cross arms complete all as specified and as directed by Engineer-in-Charge.
M & L for painting to steel poles of any type and any size including channels/cross arms with two coat of synthetic enamel paint and marking the pole No in 4” dia and substn no. yellow paint circle complete all as specified and directed by Engr-in-Charge.
M&L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white ,with letters figures and conventional skull and bones in signal red colour and fixed with MS clams,bolts and nuts of approved size for LT,20X15cm size.
M&L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white ,with letters figures and conventional skull and bones in signal red colour and fixed with MS clams,bolts and nuts of approved size for HT,25X20cm size.
M&L for repairing of pedestal panel board of any size and taking proper shut down from main, taking out rear /front broken door of the panel repair it by cutting/welding and replacing of hinges, fixing in its position and internal wiring of panel accessories like volt meter, Amp meter CTs etc with suitable size of copper wire multistranded and testing complete all as specified and directed.
M&L for painting of panel board any size scraping of old paint externally internally and making it surface for repainting painting of panel with two coats of powder coated paint internally and externally over a coat of red oxide primer all as specified and directed .
M& L for Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth for laying of cables, and getting out in loose/soft soil complete all as specified and directed by Engr-in Charge.
M&L for Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm etc complete all as specified, and directed by Engr-in Charge.
M&L for Removing excavated material (Soil) n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified, and directed.
M&L for spreading clean dry sand for cable protection/cushioning, in trenches complete all as specified and directed, (only punned down thickness shall be measured and paid).
M&L for Laying un reinforced precast concrete cable covers class LV type-I flat size 250 mm X 150 mm X 40 mm, complete all as specified and directed by Engr-in Charge.
Disconnecting the transformer of capacity 250 to 500 KVA, indoor / outdoor from HT / LT side carefully at site including dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing the 5 mm thick rubberized cork sheet gasket for tank top cover, replacement of defective bushes, reassembling the dismantled items, reconnecting the HT/LT supply cable ends at the site complete all as specified and directed by Engr-in-Charge. [NOTE: Bushes will be measured and paid separately]
All as per item No.31 as above ,but transformer of capacity 500KVA
Supply only HT bushing with insulator, brass studs, nuts and washers for the transformers of capacity 250 KVA.
Supply only LT bushing with insulator, brass studs, nuts and washers for the transformers of capacity 250 KVA.
Supply only HT bushing with insulator, brass studs, nuts and washers for the transformers of capacity 500 KVA.
Supply only LT bushing with insulator, brass studs, nuts and washers for the transformers of capacity 500 KVA.
M & L for rewinding of HT / LT transformers, by winding the defective coils with super enamelled copper wire as per IS of same gauge as per existing size together with new insulated material and aluminium bracings before placing into the transformer including assembling the HT/LT coil with new insulation between core and LT coil and fitting the coil in the chamber, testing and commissioning of the transformer and recording the test result complete all as specified and directed by Engineer-in-Charge.
M & L for on site centrifuging (dehydration) of old transformer oil at various locations of transformers of Capacity 200 KVA to 500 KVA installed on two pole/four pole structures/on platforms at Station filter action using automatic centrifuging (dehydration) machine to achieve min 40 KV breaking voltage (di-electric strength) at 2.5 mm gap for 2 minutes by absorbing and abolishing all sludge particles for use as per BS-B 66-1983 complete all as specified and directed. Notes : (a) All disconnection/re-connection of transformers HT/LT cables, T & P for required for above activity shall be arranged by contractor and quoted rates deemed to include for same. (b) Dielectric strength of the oil to be tested at site in presence of Engineer-in-charge without any extra cost and recorded the same.
Supply and fill new transformer oil ISI Marked (for topping up) confirming to IS-335 of 1993, low viscosity with dielectric strength 50 KV breaking voltage in 2.5mm gap for 2 minutes filled in transformer/OCB at various locations in Station, refixing of top cover and testing, complete all as specified and directed. (Note :- Dielectric strength of the oil to be tested at site in presence of Engineer-in-charge/JE(E/M) without any extra cost and recorded the same.)
Supply &Fill heavy duty Silica gel for breather (transparent type) suitable for transformer of 250KVA to 500KVA capacity complete all as specified and directed:-
M&L for Decarbonising / cleaning complete HT 11KV VCB 800 Amps at ICV sub stn including servicing of bus bar chamber, all electrical connections complete after removing the bus bar spout, cleaning with petrol and CRC 226 spray solution and ensure proper decarbonism, refixing the same complete all as specified and directed by the Engineer-in-Charge.Note: (if) The various unsv items required to be replaced shall be paid separately under items.
M&L for replacement of fixed contact block complete suitable for 800 Amps, 11 KV HT VCBs all as specified and directed by Engineer-in-Charge.
M&L for replacement of moving contact block complete suitable for 630/800 Amps 11 KV HT VCBs all as specified and directed by Engineer-in-Charge.
M&L for replacement of mechanical castle interlock assembly with key suitable for HT 11 KV VCB of rating 800 Amps complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of closing coil assembly 230 volts AC/ 24 volts DC, all as specified and directed by Engineer-in-Charge.
M&L for replacement of Tripping coil with plunger assembly 230 volts AC/24V DC, all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by scraping, removing, cleaning, of oil, grease painting of transformer externally and applying two coat of heat resistant synthetic enamel paint of colour as directed by spray painting including writing MES No and SM No on transformer body with synthetic enamel paint complete all as specified and directed for following capacities transformer:-
M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
M&L for cutting of roads/hard standing for laying of cables to a width of 20cm and depth of 30cm and making good the disturbed portion in PCC 1:3:6 type C1 using 20mm aggregates including removal of debris to a distance not exc 50m complete all as specified and directed.
M&L for Laying GI tubing 40 mm light grade with all fittings for cable protection fixing on poles & road/drainage crossing complete all as specified and directed by Engr-in Charge.
Supply & Fixing street light 25 watt LED fittings IP 66 complete with driver and , suitable for mounting on 40mm or 50mm dia existing GI mast or bracket arms with pole fixing attachments complete all as specified and directed by Engr-in Charge. Make : havells cat no.ENDURAPEARLSL25WLED757SASYTOPCMP/ Crompton/luker/Bajaj/Syska
Supply and fixing in replacement of LED flood lights 70Watt consist of a die cats body with heat resistant toughened glass & IP66 protection level in pressure die cast aluminium housing complete with all accessories all as specified and directed by Engr-in-Charge. Make : Make Havells cat Pt No. JETAPROFL70WLED757LTG or equivalent in /Crompton Greaves/BAJAJ/syska
Supply & jointing heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 185-300 Sq mm 3.5 core complete with treating of cable to make ready for jointing all as specified and as directed. Make : ISI marked
All as per item No. 51 here in before but suitable for cable size 50-120 sq mm.
S&F Solar PV module high efficiency polycrystlline solar light 4 watt maintenance free lithium battery with expected life of 1000cycles backup for 3days high efficiency long life LED 400lumen,6000k , IP65 protection with PIR sensor complete all as specified and directed. Make Havells cat no.LHKOAEPFF46K004 or equivalent C&S/CG/Bajaj
S&Fbusbar chamber of MS sheet metal box size 450mmx450mmx300mm on angle iron(size 25x25x5mm) frame grouted in PCC with aluminium busbar installed on porcelain insulator suitable for 200 amps rating as a cable jointer including painting complete all as specified and directed by Engr-in-charge.
Mavee Syndicate
NIKESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .