| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹44.3 L+₹6.1 L (16.1%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | L3₹45.5 L+₹7.3 L (19.2%)Rejected-Finance | L3 | Rejected-Finance HIGHER RATE |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
5 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY BHUJ
BHUJ
SPL REPAIR TO MAG 09 OF BDE GP OMC AND SPL REPAIR TO LIGHTING PROTECTION SYSTEM AT AMN UNDER AGE BR II OF GE ARMY BHUJ
2024_MES_670700_1
8229
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹89,000
Yes
29 Oct 2024
3 Sept 2024
7 Oct 2024
3 Sept 2024
5 Oct 2024
16 Sept 2024
Amount
Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls ,ceiling etc including raking out joints ,hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed.
Demolition of concrete block masonry built in cement mortar or cement lime mortar complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry 1:3:6 Type C1 (using 20mm graded aggregate) with solid blocks, exc. 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M & L for Pre-cast reinforced cement concrete slab 1:2:4 Type B1(using 20mm graded aggregate) for Heat and mess ventilations n.exc 0.50 sqm and 100 mm thick set in cement mortar 1:4 complete with joints to math size and shape complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement mixed with water proofing compound complete all as specified and directed. (Note :- WPC shall be measured & paid separately)
M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10 mm thick rendering on surfaces other than fair faces of brick/concrete surfaces in CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed.
Supply only Integral waterproofing compound.complete all as specified and directed.
M & L for providing and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of walls & applying two coats distemper oil- emulsion , white or tinted over and including a coat of primer surfaces of wall complete all as specified and directed.
M&L for preparation of old surfaces by complete removal of existing treatment and applying two coats of oil bound distemper over and including one coat of primer on ceiling complete all as specified and directed.
M&L for preparation of new surfaces of wall including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of cement paint and other foreign material, scrapping down, moss and efflorescent salts, washing, rubbing down and stopping of painted surface and applying comougflage pattern Two coats of cement base paint over a coat of primer incl watering and curring of surfaces adequately before and after application of cement base paint compelete all as specified and directed.
M&L for preparation of old decorated surfaces of comougflage pattern wall including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of cement paint and other foreign material, scrapping down, moss and efflorescent salts, washing, rubbing down and stopping of painted surface and applying Two coats of cement base paint incl watering and curring of surfaces adequately before and after application of cement base paint compelete all as specified and directed.
M & L for providing and applying putty of 1 mm thickness over Old plastered surface to prepare the surface even and smooth complete all as specified and directed.
M&L for preparation of old surfaces by complete removal of existing treatment and applying two coats of oil bound distemper over one coat of primer on walls complete all as specified and directed.
M&L for preparation of old camouflage pattern steel painted surfaces exc 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
Resecuring or easing & adjusting of Frame and shutters without taking down of any description exc 1.0 Sqm each but n. exc 2.0 Sqm each complete all as specified and directed.
Resecuring or easing & adjusting of Frame and shutters With/ without taking down of any description and Size complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples complete all as specified and directed.
M & L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, APP Membrane etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
M & L for PCC 1:2:4 type B1 (using 12.5 mm graded aggregate) as in hold fast, cill etc with necessarry form work complete all as specified and directed.
M&L for brushing neat cement slurry with 3 Kg/Sqm of cement complete incl complete removal of existing roof treatment complete all as specified and directed.
M & L for 25mm thick PCC of 1:2:4 type B-1 (using 20mm graded stone aggregate) for padding complete all as specified and directed.
M&L Rendering 10 mm thick of CM 1:4 on concrete roof surfaces is to be finished even and smooth without using extra cement with mixing water proofing compound @3% by weight complete all as specified and directed.
M&L in repairs Mineral finish APP based polymeric membrane minimum weight 4.80 Kg/Sqm and Minimum 3 mm thick reinforced with polyester non wove fabric (Wt. not less than 160 gms/Sqm land on primed surface by torched application completed all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
M & L for Granolithic concrete 1:1:2 floor topping 75 mm thick; laid over cement concrete sub floors etc. and finished to an even and fair surface complete all as specified and directed.
M & L for Cement concrete in foundations, filling and mass concrete using type B2 1:2:4 (using 40 mm graded aggregate) complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6 type D-2 (using 40mm graded stone aggregate) as in as in sub base complete all as specified and directed.
M&L for removal of existing loose damage concretye, dust, oil, paint, grease, etc from structural member like roof slab, beam, column, chajja, etc exposed fully if any corroded steel in the repair area and remove all the scale and corrosion deposite and applying Dr fixit rust removal and Epoxy Zinc Primer over the cleaned steel bars if and pour the mixed Dr fixit micro concrete into a watertight shuttering after primed by one coat of Dr fixit Epoxy bonding. Thickness or depth of an area n. exc 10cm and all as per manufacture instruction complete all as specified and directed. (Note - The rate included S&F of addition reinforcement bars if any required.)
M & L for RCC type M-25 Nominal mix (using 20mm graded aggregates) as in lintel over 1.5 m span, complete all as specified and as directed.
M & L for RCC type M-25 Nominal mix (using 20mm graded aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams mid beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M & L for Formwork to sides and soffits of floor mid beam ,roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M & L for Additional rebars 10mm dia and above providing and fixing additional corrosion resistant hot dip galvanised steel rebar Fe 415 or high grade as per required diameter in various structural elements to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive complete all as specified and directed.
Providing & applying Rising damp-proof coating system with Single component ready to use damp-proof coating Roff Hydamp : 1.SURFACE PREPARATION: Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non- moving cracks having width upto 5 mm must be filled with Polymer based crack filler. 2 APPLICATION: Apply the first coat of Dr Fixit Dampguard Classic with a paintbrush directly on the prepared surfaces by mixing ( 1 part base:1 part hardner: 1 part of water) . Allow to dry for a minimum 2-3 hrs. Apply one part of DAMPGUARD mixed chemical and 2 parts of OPC white cement/Birla Putty and make the Putty, apply Putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the Final coat of Dr Fixit Dampguard Classic on the entire surface and allow the surface to air cure 48 Hrs proceeds to paint.
Supply and fixing in repair LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including testing existing and replacing which are unservicable complete all as specified and directed.
S &F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S &F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
M&L for flame proof distribution board SPN 8 way (total enclosed dust and flame proof IP 65 protection) including dlame proof MCB SP 5 to 30 A 240 Volts AC 10KA (4 Nos) ans SPN 20A 230V Ac 50 Hz 16KA (01 Nos) flame proof suitable for gas group I/IIA/IIB/IIC as per IS-2148 of 1981 having degree of protection IP-55 as per IS-2147 of 1962 cast aluminium alloy LM-6 construction light gray epoxy shade No 631 of IS-5 powder coating having provision for one number internal and two num,ber external screws for earthing also having O ring neoprene rubber gasket hardware in external steel construction havoing two number ET-1 to 1/4 ET bracket incoming and 12 Nos 3/4 ET outgoing cable entry from bottom side also having terminals 4 nos suitable for 200A Aluminium busbar type and 12 nos 2.5/4 sqmm clip on type and certified flame proof by CMRI Dhanbad complete all as specified and directed.
M&L for Wiring for circuit/submain wiring alongwith earth wire of sizes 2X 2.5 sqmm and 1X1.5sqmm of FRLS,1100V, ISI marked is PVC insulated copper conductor, single core cable drawn in and including surface mounted ERW stove enameled metallic rigid conduit of 25mm dia with necessary fixing accessories and fititng such a s tees,bend elbow conncetor complete all as specified and directed. NOTE: Two run of 2.5 sqmm, one run of 1.5sqmm earth conductor and one RM of ERW conduit shall be measured as one meter
Supply and fixing MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F flame proof 4 way junction box with IP 66 complete all as specified and directed .
Supply and fix in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 16 sqmm 4 core complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations / taking out / in cables / pipes etc. or for shafts, well cess pits, manholes, pier holes, etc. but not exceeding 10 Sqm on plan and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soil complete all as specified and directed.
Removing surplus soil obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting paint complete all as specified and directed.
Supply and fill dry river sand in trenches for cable cushioning over and below the cable complete all as specified and directed. ( The punned thickness shall only bev measured)
Supply and fix precast concrete cable covers class LV type 1, flat size 250 x 150 x 40 mm M-20 grade concrete laid dry for cable protection complete all as specified and directed.
Supply and fix in repair single point air termination aluminium rod, 12 mm dia, 300 mm long amd removing exsiting LA system complete all as specfied and directed.
Supply and laying 40 mm bore galvanized steel tubing, medium grade (For fixing air termination rod as pipe post with all fittings laid in trenches / road / etc complete as all specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded aggregates) as in copings(150x150x200 mm) for holding GI pipe kneelers, apex stones, bed plates, kerbs etc. water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall /roof on insulatoror recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25 mm x 3 mm aluminium strip all as specified and directed .
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and fix test point termination block of size 75 mm x 75 mm x 25 mm made of Gun Metal or phospherous bronze drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw and box of size 90 x 90 x 90 mm (Made out of 1.6 mm thickplain brass sheet) and screwed to wall for protection of test point complete all as specified and directed.
Supply, install, test & commissioning of microprocessor based networkable analogue addressable upto 128 nodes 1 loop fire alarm control panel, LCD display, the panel should be equipped with sufficient nos. of loop. Each loop shall have a capacity of 127 analogue addressable devices and 127 Base sounders/base sounder beacons and shall have upto 500 event logs history. Automatic battery charger, including 24 V sealed lead acid batteries sufficient for 24 hours normal working & capable of operating the system for 24 Hours during an emergency condition as required. The panel shall certified to EN54-2/EN54-4 The panel shall be fully expandable via common plug in loop driver boards, 5.25 Amp/10.25 Amp. Power supply and charger to EN-54 part4, dedicated RS232 serial port for direct PC or MODEM connection, optional remote printer. The panel shall have LAN connectivity option & all data can be controlled or stored on cloud. Panel shall have option to invert inputs and outputs complete all as specified and directed. Make- Apollo, Hochiki or Honeywell.
Supply, install, test & commissioning of analogue addressable manual call point with integral short circuit isolator, analogue addressable protocol having status LED for alarming & standby mode, electronically addressed, approved by LPCB complete all as specified and directed Make- Apollo, Hochiki or Honeywell.
Supply, fix, test & commissioning of 2 core x 1.5 sq mm. multistrand copper cable, FRLS, armoured including supply,laying through surface mounted ERW stove enameled metallic rigid conduit of 25mm dia with necessary fixing accessories and fititng such a s tees,bend elbow conncetor and fixed on wall/ceiling/loop using proper clamp/clips complete all as specified and directed.
Supply and lay PVC insulated FRLS single core copper cable of size 4 core 1.5 sqmm including supply,laying through surface mounted ERW stove enameled metallic rigid conduit of 25mm dia with necessary fixing accessories and fititng such a s tees,bend elbow conncetor complete all as specified and directed.
Supply, fix and commissioning fire alarm sounders / sierens electronic type horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation of +5 db 1500 m range complete all as specified and directed.
Supply, install, test & commissioning of analogue addressable dual relay controller with integral short circuit isolator which allow 2 independently controlled change over relays, relays operated at 30 V DC at 1 Amps having auxiliary monitored input, followed by analogue addressable protocol, electronically addressed, approved by LPCB complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on insulator or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation etc. as required of size 32 mm x 6 mm galvanised iron strip complete all as specified and directed .
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
M/s Bombay Novelty Stores (BID ID -3129584)
machine vision plus (BID ID -3129565)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .