Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.2 LAccepted-AOC KALATALAV TA ABDASA DIST KUTCH GUJARAT PIN 370 660 | KACHCHH | GUJARAT | 370660 | ₹10.2 L Quoted ₹10.6 L | L-1 | Accepted-AOC Accepted |
| 2 | L-2₹12.0 L+₹1.4 L (13.6%)Rejected-AOC 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | ₹12.0 L+₹1.4 L (13.6%) | L-2 | Rejected-AOC Rejected |
| 3 | L-3₹13.5 L+₹2.9 L (27.1%)Rejected-AOC OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | ₹13.5 L+₹2.9 L (27.1%) | L-3 | Rejected-AOC Rejected |
| 4 | L-4₹14.9 L+₹4.3 L (40.5%)Rejected-AOC | ₹14.9 L+₹4.3 L (40.5%) | L-4 | Rejected-AOC Rejected |
| 5 | L-5₹15.0 L+₹4.4 L (41.7%)Rejected-AOC | ₹15.0 L+₹4.4 L (41.7%) | L-5 | Rejected-AOC Rejected |
Tender Value
₹12.5 L
EMD Value
₹25,000
Closing Date
26 Sept 2022, 6:00 pmClosed
GE AF NALIYA No 1
GE Air Force Station Naliya No 01
REPAIR REPLACEMENT OF MCB DBs AND CEILING FAN EXHAUST FAN WALL FAN PEDESTAL FAN AT DOMESTIC AND TECHNICAL AREA AT AF STN NALIYA
2022_MES_549920_1
8843/E8
Open Tender
Civil Works
Item Rate
330 days
Naliya
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE AF NALIYA No 1
₹25,000
Yes
31 Mar 2023
5 Sept 2022
28 Sept 2022
5 Sept 2022
26 Sept 2022
19 Sept 2022
5 Sept 2022 - 12 Sept 2022
Amount
S&F MCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including taking down old unservicable DBs by dissconnecting of electrical coonection any type including connection in new DBs by using flexible pipe suitable size and making good and match with the existing surface of wall etc all as specified and directed
Description all as per Srl item No 1.00 here-in-before but 8 way
Description all as per Srl item No 1.00 here-in-before but 4 way
S&F sheet metal enclosure 4 ways double door triple pole and neutral with 415 Volt, 200 amps rated bus bar with all accessories flush in the wall including taking down old Unsv DBs by dissconnecting of electrical coonection any type and making goog including connection in new DBs by using flexible pipe suitable size and matching with the existing surface of wall etc all as specified and directed
S&F in replacment of vertical type DB ,double door Suitable for isolated neutral bar 4 ways,IP 54 protection, Door earthing,mechenical impact strength IK 08 insulated busbar assembly ,fixed in the wall with suitable nut and bolt including 4 pole MCCB 125 Amp, 16 KA fixed in DBs as incommer three phase supply including Taking down old Unsv DBs any type by disconnecting of electrical connection and connection in new DBs by using suitable size of Flexible pipe matching the existing surface of wall etc all as specified and directed.
M&L for polycarbonate Isolator 4 pole 100 Amp complete all as specified and as directed.
M&L for polycorbonate Isolator 4 pole 63 Amp complete all as specified and as directed.
S&F in replacement of MCB single pole and neutral 40 to 63amps, 240 Volts, including taking down old Unsv MCBss any type Complete all as specified and directed.
S&F in replacement of MCB single pole and neutral 32amps, 240 Volts, including taking down old Unsv MCBss any type Complete all as specified and directed.
S&F in replacement of MCB 6 to 32 amps single pole 240 Volts, Complete all as specified and directed.
S&F MCCB 4 pole, 16 to 63 Amp,16 KA, 415 volts including taking down old Unsv MCCB any type by disconnecting of electrical connection etc all as directed.
S&F in replacement of MCCB enclosure suitable for 4 pole MCCB fixed in the wall with suitable size of nut bolt including taking down existing MCCB from the panel/old enclsure and refied the same in new enclosure and match the existing surface of wall with the existing surface etc all as specified and as directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall match with the existing surface.
S&F in replacement sub main wiring drawing through PVC casing and capping with two single core 6 sq mm and one run of 6 sq mm FRLS as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed
Description all as per Srl item No 14.00 here-in-before but of size two single core 4sq mm FRLS cable with 4 sq mm .
S&F in replacement sub main wiring drawing through PVC casing and capping with 4 single core 6 sq mm and 1 run of 6 sq mm FRLS as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp including taking down old Unsv DBs any type by disconnecting of electrical connection etc all as directed
S&F in replacement of LED 43 watt luminaire recessed mounted 2x2 suitable for armstrong/grid ceiling including electrical connectin with suitable size cooper cable two core including taking down old Unsv fittings any type by disconnecting of electrical connection etc all as directed etc all as specified and as directed.
S&F in replacement of LED edge 36 watt luminaire recessed mounted 2x2 suitable for armstrong/grid ceiling including electrical connectin with suitable size cooper cable two core including taking down old Unsv fittings any type by disconnecting of electrical connection etc all as specified and as directed.
S&F in replacement of 18 W LED recess mounting 1x1 suitablr for armsstrong/grid ceiling including electrical connection with suitable size copper cable two core including taking down old unsv fittings any typeby disconnecting of electrical connection etc all as specified and as directed .
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
M&L for Spot Cheking Serviceability of ceiling fan, exhaust fan, wall mounted fan,pedestal fan,and ensure all accessories like splite pin,fan hook,rubber,clamps nut and bolt,capacitor,down rod etc and refixing the appliances after the checking/servicing or replacement of accessories,as required complete all as specified and directed. Note:-(I) The work shall be carried out in occupied quarters and the part replace will be measured under relevant items as supply only. (II) The work shall be carried on specific numbered docket issued by EIC/JE and after checking of servicability/repair,contractor shall obtained the sign of the user and return the docket for payment action. (III) All tools and plants required for the work shall be arrange by the contractor.
Taking down ceiling fan/Exhaust fan /wall monted fan/pedestal fan of any make and sweep,cleaning externally and internally. Stripping out the fans, examine the unserviceable spares/ burnt winding by testing, cleaning and lubricating bush/ bearings. Refixing the fans in same position after necessary repairs/ servicing including carring out the replacement worn out parts, body covers, screws, spilt pins nuts condensor and flexible wire copper conducter from ceiling fan to ceiling rose etc complete all as specified and as directed. Note: (i) The parts replaced will be measured nunder relevant iotem as "Supply Only" (II) All tools and plants required for the work shall be arrange by the contractor.
Removing defective winding and rewinding with new super enamelled copper wire of existing gauge and weight as per manufactures design and instructions including insulating materials and varnishing of ceiling fans of of size 1200/ 1400mm sweap of any make and re-assembling testing complete and refixing to the location including replacement of flexible copper wire from ceiling rose to ceiling fan all as directed and specified
Description all as per Item No. 24.00 here-in-before but exhaust fan of size 300/380 mm sweep.
Description all as per Item No. 24.00 here-in-before but exhaust fan of size 400/450 mm sweep.
Description all as per Item No. 23.00 here-in-before but pedestal/Air circulator fan of size 400/450 mm sweep.
Supply rubber bush for shackle with bolt, nut and lock pin suitable for Ceiling fan 1200mm / 1400mm sweep, exhaust/wallmounted fans of different make required as per the makes of existing fans as required at site or in winding shop complete all as specified and directed.
Description all as per Item No. 28.00 here-in-before but PVC holder for condenser housing.
Description all as per Item No. 28.00 here-in-before but Split Pin
Description all as per Item No. 28.00 here-in-before but Ball bearing of size No 6201/6202/6203
Description all as per Item No. 28.00 here-in-before but Gun metal bush as per sample.
Supply only Condenser (capacitor) 3.15/2.5 MFD, 440 Volts, AC 50 Hz as per IS 1709 suitable for ceiling fan 1200/1400 mm sweep complete all as specified and as directed.
Supply only Condenser 4 MFD, 440 Volts, AC 50 Hz as per IS 1709 suitable for exhaust fan 300/380/450 mm sweep complete all as specified and as directed.
S&F down rod of length appx (3 Feet) by removing and refixing of any type of ceiling complete all as specified and as directed.
S&F down rod of length appx (2 Feet) by removing and refixing of any type of ceiling complete all as specified and as directed.
S&F fan hook made out of MS Flat/round bar of suitable size with nut and bolts complete all as specified and as directed.
Ell Ess Contractor
M/s. Shree Shakti Enterprise
Komal Construction
THOMAS M. MATTACKAL
Venus Engineering
NEELKANTHA ASSOCIATE
Laxmi Enterprise
baghela construction
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .