Loading…
Loading…
Tender ID
Tender Value
₹2.4 L
EMD Value
₹4,821
Closing Date
24 Mar 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Construction of Biology Lab and Library Room at Boys Higher Secondary School Goshbugh Pattan B.W.O Electric works
2026_PWDJK_305874_1
NIT No.320/2025-26 Dt/11/03/2026
Open Tender
Electrical Works
Percentage
Goshbugh Pattan
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹4,821
11 Mar 2026
11 Mar 2026
25 Mar 2026
11 Mar 2026
24 Mar 2026
11 Mar 2026
Wiring for Light point/Exhaust fan/Fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/PolycabF/finolexMake) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Schneider /Havells/ Legrand/Anchor roma plus/ABB/Eq Make & shall be approved before execution of work (Group B)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Havells/ Legrand/ Panasonic/ Anchor/ Schneider/ABB/Eq Make & shall be approved before execution of work.
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/ Anchor/Eq Make)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor roma plus/Schneider/ABB/Eq Make & shall be approved before execution of work.
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor/EqMake)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor roma plus/Schneider/ABB/Eq Make & shall be approved before execution of work.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells/Legrand/ Panasonic/Anchor/Schneider/ABB/Eq Make
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections. (L&T/ Siemens/ Legrand/ Schneider/ ABB/ Eq Make)
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Schneider/ABB/Eq Make)
100 Amp DP for Main Supply
2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards from 100 Amp DP of One DB to the other
Supplying and Fixing of MCB 4way (4 + 12), horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make)
Supply/Installation/Testing and Commissioning of 18W + LED Surface Mounted Panel (Commerical Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/HG/Eq Make Make.
Supply/Installation/Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Havells/Polycab/Eq Make.(Minium -1Star)
Supply/Laying/Connecting and Commissioning of 35 sq.mm 2-Core XLPE/PVC insulated and Un-armoured 1.1 KV grade Aluminum Cable of Havells/Polycab/Anchor/Eq Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
Supply/Laying of 25/32/38mm Dia and 2mm thick PVC Conduit/Lockable Channel of Anchor/Ravindra Blue/Finolex/Eq Make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Paint etc.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.08 MB
BOQ_993301.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .