Hindustan Shipyard Limited Gandhigram SR Complex Visakhapatnam 530 005
Servicing of Air conditioning plant and Ref Plant of MV Vishva Malhar on Turnkey Basis
2022_HSL_89354_1
20 / 22004 / AC and Ref / 236 / 2021-22
Open Tender
Miscellaneous Services
Service
20 days
HSL Visakhapatnam
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
23 Mar 2022
12 Mar 2022
21 Mar 2022
12 Mar 2022
21 Mar 2022
12 Mar 2022
Amount
TYPE/CAPACITY/DETAILS : BITZER OPEN TYPE MULTICYLINDER MAKE:SABROE REFRIGERATIONS ARHUS,DENMARK MODEL: V, NO OF CYLINDER:2 BORE:85 MM STROKE:50 MM,SPEED:320/700,CONDENOR:02 NOS TYPE:HORIZONTAL SHELL AND TUBE MODEL: JSF606 ,RECEIVER 1 (NOS) Note: THE ENTIRE JOB TO BE EXECUTED ON TURNKEY BASIS,CONSUMABLES SPARES ETC ARE TO BE ARRANGED BY VENDOR/BIDDER
REFRIGERANT FROM THE SYSTEM TO BE COLLECTED IN YARD SUPPLY BOTTLES AND SYSTEM TO PRESSURE/VACCUM TEST FOR 36 HRS.,LEAKAGES TO BE RECTIFIED.AFTER COMPLITION OF WORK SYSTEM TO BE CHARGED WITH R404a APPROX 11 KG AND PUT IN USE.IF ANY DEFECT NOTICED , SAME TO BE RECTIFIED BY THE VENDOR WITH VENDOR SUPPLIED MATERIAL . SYSTEM TO BE STARTED AND SUCCESSFUL COOLING/SYSTEM TRIALS TO BE SHOWN TO SHIP STAFF FOR 36 HRS.NITROGEN BOTTLES,CONSUMABLES,CU PIPES,BRAZING RODS ETC ARE TO BE ARRANGED BY THE VENDOR
SIGHT GLASSES OF CONDENSER TO BE OPENED,CLEANED AND FITTED WITH NEW GASKET.
FILTER DRIER TO BE RENEWED (SHIP SUPPLY)
FISH ROOM TO BE PRESSURE TESTED, LEAKAGES TO RECTIFY AND FISH ROOM TO BE MADE OPERATIONAL AND PUT INTO USE.
PROCURE,SUPPLY AND CHARGE R404A GAS
ANY LEAKING VALVE TO BE RECTIFY/RENEWED( SPARES VENDOR SUPPLY ).IF VALVE TO BE REPLACED NEW VALVES TO BE PROCURED AND SUPPLIED BY THE VENDOR
E21037: ITEM : AIR CONDITIOINING COMPRESSOR: TYPE /CAPACITY / DETAILS:CARLYLE COMPRESSOR. TYPE:06EA575 SEMIHERMETIC,REFRIGERANT-404 A. COOLING CAPACITY:120 KW RATED POWER:35 KW. COMPRESSOR SPEED:1750 RPM Note: THE ENTIRE JOB TO BE EXECUTED ON TURNKEY BASIS,CONSUMABLES SPARES ETC ARE TO BE ARRANGED BY VENDOR/BIDDER
REFRIGERANT FROM THE SYSTEM TO BE COLLECTED IN YARD SUPPLY BOTTLES AND SYSTEM TO PRESSURE/VACCUM TEST FOR 36 HRS.,LEAKAGES TO BE RECTIFIED.AFTER COMPLITION OF WORK SYSTEM TO BE CHARGED WITH R404a AND PUT IN USE.IF ANY DEFECT NOTICED , SAME TO BE RECTIFIED BY YARD WITH YARD SUPPLIED MNATERIAL. SYSTEM TO BE STARTED AND SUCCESSFUL COOLING/SYSTEM TRIALS TO BE SHOWN TO SHIP STAFF FOR 36 HRS.NITROGEN BOTTLES,CONSUMABLES,CU PIPES,BRAZING RODS ETC ARE TO BE ARRANGED BY THE VENDOR
BOTH CONDENSOR TO BE CLEANED AND PRESSURE TESTED.CHEMICALS AND OTHER CONSUMABLES VENDOR SCOPE CONDENSOR END COVERS IF DAMAGED ,THE SAME TO BE REPAIRED BY THE VENDOR(NECESSARY SPARES/ELECTRODES MACHINING VENDOR SCOPE)
ANY LEAKING VALVE TO BE RECTIFY/RENEWED( VENDOR SUPPLY)
ACCOMODATION BLOWER (AIR HANDLING UNIT OF ACCOMODATION AIR CONDITIONING): TYPE /CAPACITY / DETAILS:TYPE-JL MARINE AND ENGINEERING PTE LTD AIR VOLUME:10500M3/H TOTAL PRESSURE:2000 PA FAN MOTOR CAPACITY: 11 KW HEATING CAPACITY:120 KW COOLING CAPAITY:125 KW HUMIDIFIER:47 KG/H Note: THE ENTIRE JOB TO BE EXECUTED ON TURNKEY BASIS,CONSUMABLES SPARES ETC ARE TO BE ARRANGED BY VENDOR/BIDDER
TWO NO. OF EVAPORATOR COILS; AIR SIDE(WITH FINS) TO CLEAN WITH CHEMICAL SPRAY/WASHING.
TWO NO. OF STEAM HEATER COILS AIR SIDE (WITH FINS) TO CLEAN WITH CHEMICAL SPRAY/JET WASHING.BENT FINS TO STAIGHTEN.
BLOWER CASING TOP/BOTTOM DAMAGED SAME TO RENEW WITH 2 MM THICK SS/MS PLATES.QUOTE FOR 2 M2 AREA OF PLATE, BOTH BLOWER FOUNDATION IF THINNED DOWN TO BE RENEWED.
AIR FILTERS OF BOTH THE BLOWERS DAMAGED,SAME TO BE RENEWED AND SUPPLY 1 SET SPARE.
ALL BLOWER FLAPS TO BE OVERHAULED
BOTH AHU BLOWERS BEARINGS TO BE RENEWED. PULLEYS TO BE CHECKED FOR WEAR DOWN AND RENEWED IF REQUIRED.
ALL TEMP GAUGES TO BE RENEWED.
BOTH AHU EVAPORATOR COILS FINS DAMAGED . RENEWAL OF COILS OR DAMAGED FINS TO BE CARRIED OUT.
M/s Kalyani Marine And Industrial Engineers
Sri Balaji Marine and Civil Engg Works
GOKUL ENGINEERING ASSOCIATES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .