Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-I₹21.6 LAccepted-AOC CHIEF ENGINEER OP KANGRA ZONE HPSEBL DHARAMSHALA | KANGRA | HIMACHAL PRADESH | 175013 | L-I | Accepted-AOC L-I Accepted | |
| 2 | L-II₹43.4 LRejected-AOC A CLASS GOVT ELECTRICAL CONTRACTOR VPO CHOBIN TEHSIL BAIJNATH DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L-II | Rejected-AOC Higher amount Quoted | |
| 3 | L-III₹47.1 LRejected-AOC 25 IND AREA PH II NAGROTA BAGWAN DISTT KANGRA HP | NAGROTA BAGWAN | KANGRA | HIMACHAL PRADESH | L-III | Rejected-AOC Higher amount Quoted | |
| 4 | Not Admitted-Fee VILL CHANDPUR P O KHOUDA SUB TEHSIL TIHRA DISTT MANDI | MANDI | HIMACHAL PRADESH | 175001 | - | Not Admitted-Fee Fee not received |
Tender Value
Refer Docs
EMD Value
₹67,181
Closing Date
24 May 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE (OP) Circle HPSEBL Mandi
SE (OP) Circle HPSEBL Mandi
Estimate for Prov. SOP to LWSS for Group of villages in GP Ropari, Chowk, Parsada Hawani and Janjehali in Tehsil Sarkaghat in ESD Dharampur and Tihra under ED HPSEBL Dharampur
2021_HPSEB_47159_2
4/2021-22
Open Tender
Supply and Erection
Turn-key
180 days
SE (OP) Circle HPSEBL Mandi
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,040
SR XEN HPSEBL Mandi
₹67,181
21 Jun 2021
19 May 2021
25 May 2021
19 May 2021
24 May 2021
19 May 2021
30 days
Amount
A Cost of 11 KV HT Line (for Raw water stage & First stage at Bahri).
Erection of ACSR 6/1/4.72 100 mm sq.) {Includes 3 conductor lengths for 3 phase and additional 3% (sag,Jumpering wastage}(Provided by HPSEBL)
Prov. Run Thro Structures (delta Formation): Steel Tubular Poles (11 Mtr, working load >227 kgf/m sq.)
Prov. RCC Muff with concrete filling
Dead End Structure on Double poles:
Belt set-MS Angle Iron: 50x50x6, length [1500 mm x 2 No.]
X-Bracing Set-MS Angle Iron: 50x50x6, length [2125 mm x 2 Nos.]
X-arm (Horizontal)- MS Channel Iron: 100x50x6, length [2140 mm x 2 Nos.]
Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 45 KN,) i/c Dead end clamps etc.) x (3 Nos. conductors) x (2 Nos. sides)
11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure
HT Stay/ Guy Arrangement
Prov. Stay set complete in all respect (1 No/ single pole, 4 no/ double pole structure)
Prov. Stay Wire (7/3.15 mm) (@ 6.0 Kg. Per Stay Set)
Earthing
Prov. HT earthing set complete
Single continuous earth wire (GI 8 SWG) {a/w 1 wire lengths for avg. one road crossing @ 20 mtr and additional 1% (sag and wastage )} @ 0.102 kg/mtr
Eye Hook for earth wire
Earth wire clamp
Full Clamps (on DP & SP structure )
Prov. 11 KV Danger Plate (250x200x1.60 mm)
Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]
Prov. Barbed Wire
Prov. Alluminium Paint .
B ABSTRACT OF COST 100 KVA SUB-STATION for Raw stage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos]
X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
MS Angle Iron (50X50x6 mm), Length: 2800 mm x(1 Nos for LA's + 2 No. for Dist Panel Box)
GO AB Switch Unit (11kV, 400A, 25 KA )
D.O Fuse Unit
Surge Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Pipe Earthing Set
LT Distribution Panel Box with MCCB(160A,10KA,4P, 1 No.) & SFU (32A, 5No. Rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Erection of 11 KV CT PT unit PT (1 Unit, 11 kV/110 V) ; CT(3No, 10-200/5A)(Provided by HPSEBL)
Prov. & fixing 3 Phase 3/4 wire CT-PT Operated Static Trivector Meter, (PT ratio-11KV/110V, CT Ratio-25/5A)
Aluminium Paint.
C ABSTRACT OF COST 250 KVA SUB-STATION for 1st Stage stage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos]
X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
MS Angle Iron (50X50x6 mm), Length: 2800 mm x(1 Nos for LA's + 2 No. for Dist Panel Box)
GO AB Switch Unit (11kV, 400A, 25 KA )
D.O Fuse Unit
Surge Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Pipe Earthing Set
LT Distribution Panel Box with MCCB(400A,36KA,4P, 1 No.) & SFU (100A, 1No. Rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Erection of 11 KV CT PT unit PT (1 Unit, 11 kV/110 V) ; CT(3No, 10-400/5A)(Provided by HPSEBL)
Prov. & fixing 3 Phase 3/4 wire CT-PT Operated Static Trivector Meter, (PT ratio-11KV/110V, CT Ratio-25/5A)
Aluminium Paint.
D Cost of 11 KV HT Line (for 2nd stage ).
Erection of ACSR 6/1/4.72 100 mm sq.) {Includes 3 conductor lengths for 3 phase and additional 3% (sag,Jumpering wastage}(Supplied by HPSEBL)
Prov. Run Thro Structures (delta Formation): Steel Tubular Poles (11 Mtr, working load >227 kgf/m sq.)
Prov. RCC Muff with concrete filling
Run Thro' structures on Single poles:
Cross Arm: [Channel Iron (100x50x6 mm), Length (1070) mm x 8 structure
Angle Iron (50x50x6 mm), Length (2x750) mm x 8 structures
Pole Top Bracket
11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure
Dead End Structure on Double poles:
Belt set-MS Angle Iron: 50x50x6, length [1500 mm x 2 No.]
X-Bracing Set-MS Angle Iron: 50x50x6, length [2125 mm x 2 Nos.]
X-arm (Horizontal)- MS Channel Iron: 100x50x6, length [2140 mm x 2 Nos.]
Disc insulators set on dead end structure (comprising 1 No. Disc: ^^(Porcelian, BS, 12 KV, 90 KN,) i/c Dead end clamps etc.) x (3 Nos. conductors) x (2 Nos. sides)
11 KV Pin insulators (Porcelian, 12 KV, 10 KN): 3 Nos. per double pole structure
HT Stay/ Guy Arrangement
Prov. Stay set complete in all respect (1 No/ single pole, 4 no/ double pole structure)
Prov. Stay Wire (7/3.15 mm) (@ 6.0 Kg. Per Stay Set)
Earthing
Prov. HT earthing set complete
Single continuous earth wire (GI 8 SWG) {a/w 1 wire lengths for avg. one road crossing @ 20 mtr and additional 1% (sag and wastage )} @ 0.102 kg/mtr
Eye Hook for earth wire
Earth wire clamp
Half Clamps (on Run thro structure)
Full Clamps (on DP & SP structure )
Prov. 11 KV Danger Plate (250x200x1.60 mm)
Prov.M.S. Nuts & Bolts of various sizes (Gulvanised/ coated) [Preferably 16 mm Dia or more (with flat and spring washers)]
Prov. Barbed Wire
Prov. Alluminium Paint .
E ABSTRACT OF COST 630 KVA SUB-STATION for 2nd Stage stage
Steel Tubular Poles (9 m, Working Load > 200 kgf/m²)
Muffs with concerete filling
X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos]
X-Arm: [Channel Iron (75x40x6 mm), Length : 2800 mm X 4 Nos] for supporting DO fuse unit & GO switch
MS Angle Iron (50X50x6 mm), Length: 2800 mm x(1 Nos for LA's + 2 No. for Dist Panel Box)
GO AB Switch Unit (11kV, 400A, 25 KA )
D.O Fuse Unit
Surge Arrester, 9 kV Station Class (Porcelain Type)
Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.)
Stay set complete
Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set)
Pipe Earthing Set
LT Distribution Panel Box with MCCB(400A,36KA,4P, 1 No.) & SFU (100A, 1No. Rewirable)
Half Clamp (M.S. Flat 50X6 mm)
Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)]
Aluminium Thimble
Aluminium Thimble
Danger Plate
Erection of 11 KV CT PT unit PT (1 Unit, 11 kV/110 V) ; CT(3No, 10-1000/5A)(Provided by HPSEBL)
Prov. & fixing 3 Phase 3/4 wire CT-PT Operated Static Trivector Meter, (PT ratio-11/110V, CT Ratio-50/5A)
Aluminium Paint.
AGR Engineers
M/S DEVARYA ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .